Comparison of the performance of four elastomeric devices, Eur J Hosp Pharm Pract, vol.11, issue.2, pp.54-56, 2005. ,
The Delivery Rate Accuracy of Portable Infusion Pumps Used for Continuous Regional Analgesia, Anesthesia & Analgesia, vol.95, issue.5, pp.1331-1336, 2002. ,
DOI : 10.1097/00000539-200211000-00043
Delivery Rate Accuracy of Portable, Bolus-Capable Infusion Pumps Used for Patient-Controlled Continuous Regional Analgesia, Regional Anesthesia and Pain Medicine, vol.28, issue.1, pp.17-23, 2003. ,
DOI : 10.1097/00115550-200301000-00004
Portable Infusion Pumps Used for Continuous Regional Analgesia, Regional Anesthesia and Pain Medicine, vol.28, issue.5, pp.424-432, 2003. ,
DOI : 10.1097/00115550-200309000-00012
Performance of three portable infusion-pump devices set to deliver 2mL/h, Am J Health-Syst Pharm, vol.54, pp.1277-1280, 1997. ,
Evaluation of flow rates for six disposable infusion devices, Am J Health Syst Pharm, vol.52, pp.500-504, 1995. ,
Evaluation of the design and reliability of three elastomeric and one mechanical infusers, Journal of Oncology Pharmacy Practice, vol.23, issue.9, pp.77-84, 2007. ,
DOI : 10.1177/1078155207078349
SD 5 n°2001-502 du 22 octobre 2001 relative à l'organisation des soins pour la prise en charge des patients atteints de mucoviscidose ,
La mucoviscidose en 2008, La Revue de M??decine Interne, vol.29, issue.11, pp.901-907, 2008. ,
DOI : 10.1016/j.revmed.2007.12.020
CFTR: More than just a chloride channel, Pediatric Pulmonology, vol.6, issue.4, pp.292-298, 2005. ,
DOI : 10.1002/ppul.20147
Microbiology of early CF lung disease, Paediatric Respiratory Reviews, vol.5, pp.367-369, 2004. ,
DOI : 10.1016/S1526-0542(04)90065-6
Pulmonary Abnormalities on High-Resolution CT Demonstrate More Rapid Decline Than FEV1 in Adults With Cystic Fibrosis, Chest, vol.130, issue.5, pp.1424-1432, 2006. ,
DOI : 10.1378/chest.130.5.1424
Protocole national de diagnostic et de soins pour une maladie rare, 2006. ,
Antimicrobial resistance of Pseudomonas aeruginosa biofilms, Microbes and Infection, vol.5, issue.13, pp.1213-1219, 2003. ,
DOI : 10.1016/j.micinf.2003.08.009
Treatment of superinfections caused by pyocyanic bacillus in patients with mucoviscidosis. Efficacy of cefsulodin in combination with an aminoglycoside, Pathol Biol (Paris), vol.37, issue.5, pp.500-503, 1989. ,
Efficacy, safety, and local pharmacokinetics of highly concentrated nebulized tobramycin in patients with cystic fibrosis colonized with Pseudomonas aeruginosa, Paediatr Drugs, vol.9, issue.1, pp.11-20, 2007. ,
Fosfomycin therapy for multiresistant Pseudomonas aeruginosa in cystic fibrosis, Journal of Cystic Fibrosis, vol.2, issue.1, pp.19-24, 2003. ,
DOI : 10.1016/S1569-1993(02)00143-1
ANTIBIOTIC TREATMENT OF STAPHYLOCOCCUS AUREUS INFECTION IN CYSTIC FIBROSIS, Acta Paediatrica, vol.36, issue.5, pp.821-826, 1982. ,
DOI : 10.1016/S0022-3476(81)80282-X
Macrolides in cystic fibrosis, Clin Chest Med, vol.28, pp.347-360, 2007. ,
A randomized crossover trial assessing patient preference for two different types of portable infusion-pump devices, Annals of Oncology, vol.10, issue.6, pp.727-729, 1999. ,
DOI : 10.1023/A:1008334313918
Les appareils ??lectriques de perfusion, Annales Fran??aises d'Anesth??sie et de R??animation, vol.13, issue.3, pp.350-359, 1994. ,
DOI : 10.1016/S0750-7658(94)80043-X
Ambulatory perineural local anesthetic infusion: Portable pump and dosing regimen selection, Techniques in Regional Anesthesia and Pain Management, vol.8, issue.2, pp.90-98, 2004. ,
DOI : 10.1053/j.trap.2004.02.005
URL : http://ufdc.ufl.edu/LS00001404/00002
Comparison of the performance of four elastomeric devices, Eur J Hosp Pharm Pract, vol.11, issue.2, pp.54-56, 2005. ,
Evaluation of a disposable, elastomeric infusion device in the home environment, Am J Hosp Pharm, vol.49, pp.1712-1716, 1992. ,
Performance of selected flow-restricting infusion devices, Am J Health Syst Pharm, vol.55, pp.351-359, 1998. ,
The Delivery Rate Accuracy of Portable Infusion Pumps Used for Continuous Regional Analgesia, Anesthesia & Analgesia, vol.95, issue.5, pp.1331-1336, 2002. ,
DOI : 10.1097/00000539-200211000-00043
Delivery Rate Accuracy of Portable, Bolus-Capable Infusion Pumps Used for Patient-Controlled Continuous Regional Analgesia, Regional Anesthesia and Pain Medicine, vol.28, issue.1, pp.17-23, 2003. ,
DOI : 10.1097/00115550-200301000-00004
Portable Infusion Pumps Used for Continuous Regional Analgesia, Regional Anesthesia and Pain Medicine, vol.28, issue.5, pp.424-432, 2003. ,
DOI : 10.1097/00115550-200309000-00012
Evaluation of the design and reliability of three elastomeric and one mechanical infusers, Journal of Oncology Pharmacy Practice, vol.23, issue.9, pp.77-84, 2007. ,
DOI : 10.1177/1078155207078349
Performance of three portable infusion-pump devices set to deliver 2mL/h, Am J Health-Syst Pharm, vol.54, pp.1277-1280, 1997. ,
La vitesse de perfusion de la plupart des pompes ?? perfusion non ??lectriques jetables diminue dans des conditions hypobares, Canadian Journal of Anesthesia/Journal canadien d'anesth??sie, vol.17, issue.7, pp.657-662, 2003. ,
DOI : 10.1007/BF03018707
Perfusion continue de la Tazocilline : essai de corrélation entre dosage et temps d'écoulement, 2009. ,
Disposable infusion pumps, American Journal of Health-System Pharmacy, vol.63, issue.13, pp.1260-1268, 2006. ,
DOI : 10.2146/ajhp050408
Comparison of accuracy and cost of disposable, nonmechanical pumps used for epidural infusions, Regional Anesthesia and Pain Medicine, vol.22, issue.3, pp.260-266, 1997. ,
DOI : 10.1016/S1098-7339(06)80012-X