F. Michard, Changes in Arterial Pressure during Mechanical Ventilation, Anesthesiology, vol.103, issue.2, pp.419-428, 2005.
DOI : 10.1097/00000542-200508000-00026

F. Michard and J. Teboul, Predicting Fluid Responsiveness in ICU Patients, Chest, vol.121, issue.6, 2000.
DOI : 10.1378/chest.121.6.2000

D. Osman, C. Ridel, P. Ray, X. Monnet, N. Anguel et al., Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge*, Critical Care Medicine, vol.35, issue.1, pp.64-68, 2007.
DOI : 10.1097/01.CCM.0000249851.94101.4F

A. Perel, Assessing Fluid Responsiveness by the Systolic Pressure Variation in Mechanically Ventilated Patients, Anesthesiology, vol.89, issue.6, pp.1309-1310, 1998.
DOI : 10.1097/00000542-199812000-00005

H. Berkenstadt, N. Margalit, M. Hadani, Z. Friedman, E. Segal et al., Stroke Volume Variation as a Predictor of Fluid Responsiveness in Patients Undergoing Brain Surgery, Anesthesia and Analgesia, vol.92, pp.984-989, 2001.
DOI : 10.1097/00000539-200104000-00034

G. Manecke, Edwards FloTrac??? sensor and Vigileo??? monitor: easy, accurate, reliable cardiac output assessment using the arterial pulse wave, Expert Review of Medical Devices, vol.2, issue.5, pp.523-527, 2005.
DOI : 10.1586/17434440.2.5.523

S. Rex, S. Brose, S. Metzelder, R. Huneke, G. Schalte et al., Prediction of fluid responsiveness in patients during cardiac surgery, British Journal of Anaesthesia, vol.93, issue.6, pp.782-788, 2004.
DOI : 10.1093/bja/aeh280

C. Hofer, S. Muller, L. Furrer, R. Klaghofer, M. Genoni et al., Stroke Volume and Pulse Pressure Variation for Prediction of Fluid Responsiveness in Patients Under oing Off-Pump Coronary Artery Bypass Grafting, Chest, vol.128, issue.2, pp.848-854, 2005.
DOI : 10.1378/chest.128.2.848

C. Hofer, A. Senn, L. Weibel, A. Zollinger, G. Langewouters et al., Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system The pressure dependent dynamic elasticity of 35 thoracic and 16 abdominal human aortas in vitro described by a five component model, Crit Care J Biomech, vol.12, issue.18, pp.82613-620, 1985.

B. Pratt, L. Roteliuk, F. Hatib, J. Frazier, and R. Wallen, Calculating Arterial Pressure-Based Cardiac Output Using a Novel Measurement and Analysis Method, Biomedical Instrumentation & Technology, vol.41, issue.5, pp.403-411, 2007.
DOI : 10.2345/0899-8205(2007)41[403:CAPCOU]2.0.CO;2

J. Penttila, A. Snapir, E. Kentala, J. Koskenvuo, J. Posti et al., Estimation of cardiac output in a pharmacological trial using a simple method based on arterial blood pressure signal waveform: a comparison with pulmonary thermodilution and echocardiographic methods, European Journal of Clinical Pharmacology, vol.9, issue.6, pp.401-407, 2006.
DOI : 10.1007/s00228-006-0115-1

M. Sander, C. Spies, H. Grubitzsch, A. Foer, M. Muller et al., Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements Validation of a new arterial pulse contour-based cardiac output device, Crit Care Med, vol.35, pp.1904-1909, 2007.

J. Mayer, J. Boldt, M. Wolf, J. Lang, and S. Suttner, Cardiac Output Derived from Arterial Pressure Waveform Analysis in Patients Undergoing Cardiac Surgery: Validity of a Second Generation Device, Anesthesia & Analgesia, vol.106, issue.3, pp.867-872, 2008.
DOI : 10.1213/ane.0b013e318161964d

J. Mayer, J. Boldt, T. Schollhorn, K. Rohm, A. Mengistu et al., Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery, British Journal of Anaesthesia, vol.98, issue.2, pp.176-182, 2007.
DOI : 10.1093/bja/ael341

D. Rocca, G. Costa, M. Chiarandini, P. Bertossi, G. Lugano et al., Arterial Pulse Cardiac Output Agreement With Thermodilution in Patients in Hyperdynamic Conditions, Journal of Cardiothoracic and Vascular Anesthesia, vol.22, issue.5, pp.681-687, 2008.
DOI : 10.1053/j.jvca.2008.02.021

M. Biais, K. Nouette-gaulain, V. Cottenceau, A. Vallet, J. Cochard et al., Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis table of contents Performance of a minimally invasive uncalibrated cardiac output monitoring system (Flotrac/Vigileo) in haemodynamically unstable patients Thuemer O, van Hout N: Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis, 21. P. Vignon BC, M. Slama, A. Vieillard-Baron: Echocardiographie Doppler chez le patient en état critique ; Interactions cardio-pulmonaires, pp.1480-1486451, 2007.

F. Jardin, J. Farcot, P. Gueret, J. Prost, Y. Ozier et al., Cyclic changes in arterial pulse during respiratory support, Circulation, vol.68, issue.2, pp.266-274498, 1983.
DOI : 10.1161/01.CIR.68.2.266

B. Tavernier, O. Makhotine, G. Lebuffe, J. Dupont, and P. Scherpereel, Systolic Pressure Variation as a Guide to Fluid Therapy in Patients with Sepsis-induced Hypotension, 25. SRLF J-LTelgdedl: Recommandations d'experts de la SRLF : "Indicateurs du remplissage vasculaire au cours de l'insuffisance circulatoire": Réanimation, pp.1313-1321, 1998.
DOI : 10.1097/00000542-199812000-00007

M. Lopes, M. Oliveira, V. Pereira, I. Lemos, J. Auler et al., Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial, Critical Care, vol.11, issue.5, p.100, 2007.
DOI : 10.1186/cc6117

O. Goedje, K. Hoeke, M. Lichtwarck-aschoff, A. Faltchauser, P. Lamm et al., Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: comparison with pulmonary arterial thermodilution Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators, Crit Care Med Br J Anaesth Br J Anaesth, vol.27, issue.95, pp.2407-2412761, 1999.

M. Cannesson, H. Musard, O. Desebbe, C. Boucau, R. Simon et al., The Ability of Stroke Volume Variations Obtained with Vigileo/FloTrac System to Monitor Fluid Responsiveness in Mechanically Ventilated Patients, Anesthesia & Analgesia, vol.108, issue.2, pp.513-517, 2009.
DOI : 10.1213/ane.0b013e318192a36b

M. Kobayashi, M. Koh, T. Irinoda, E. Meguro, Y. Hayakawa et al., Stroke Volume Variation as a Predictor of Intravascular Volume Depression and Possible Hypotension During the Early Postoperative Period After Esophagectomy, Annals of Surgical Oncology, vol.86, issue.5, pp.1371-1377, 2009.
DOI : 10.1245/s10434-008-0139-0

M. Pinsky, Probing the Limits of Arterial Pulse Contour Analysis to Predict Preload Responsiveness, Anesthesia & Analgesia, vol.96, pp.1245-1247, 2003.
DOI : 10.1213/01.ANE.0000055821.40075.38

R. Chatti, S. De-rudniki, S. Marque, A. Dumenil, A. Descorps-declere et al., Comparison of two versions of the Vigileo-FloTracTM system (1.03 and 1.07) for stroke volume estimation: a multicentre, blinded comparison with oesophageal Doppler measurements, British Journal of Anaesthesia, vol.102, issue.4, pp.463-469725, 2008.
DOI : 10.1093/bja/aep020

J. Mayer, J. Boldt, R. Poland, A. Peterson, G. Manecke et al., Continuous Arterial Pressure Waveform???Based Cardiac Output Using the FloTrac/Vigileo: A Review and Meta-analysis, Journal of Cardiothoracic and Vascular Anesthesia, vol.23, issue.3, pp.401-406819, 1996.
DOI : 10.1053/j.jvca.2009.03.003

J. Graftieaux, J. Benkirane, P. Gomis, B. Scherpereel, L. A. Dharmavaram et al., Effect of prone positioning systems on hemodynamic and cardiac function during lumbar spine surgery: an echocardiographic study Hemodynamic effect of the prone position during anesthesia Y: Hemodynamic evaluation of the prone position by transesophageal echocardiography Hemodynamic changes during spinal surgery in the prone position The effect of the prone position on pulmonary mechanics is frame-dependent, Agressologie Spine Acta Anaesthesiol Scand J Clin Anesth Acta Anaesthesiol Taiwan Anesth Analg, vol.34, issue.87, pp.53-541388, 1991.

D. Chemla, J. Hebert, C. Coirault, K. Zamani, I. Suard et al., Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients, Am J Physiol Intensive Care Med, vol.274, issue.29, pp.500-505476, 1998.

D. Backer and D. , Can passive leg raising be used to guide fluid administration? Crit Care 10:170, 2006. 47. Monnet X, Teboul JL: Passive leg raising, Intensive Care Med, vol.34, pp.659-663, 2008.

J. Jabot, J. Teboul, C. Richard, and X. Monnet, Passive leg raising for predicting fluid responsiveness: importance of the postural change, Intensive Care Medicine, vol.10, issue.1, pp.85-90, 2009.
DOI : 10.1007/s00134-008-1293-3

S. Thiel, M. Kollef, and W. Isakow, Non-invasive stroke volume measurement and passive leg raising predict volume responsiveness in medical ICU patients: an observational cohort study, Critical Care, vol.13, issue.4, p.111, 2009.
DOI : 10.1186/cc7955