». Glucose, Première partie : analyse descriptive de l'activité « Mesure continue du, p.23

A. , C. De-grenoble, and .. , Analyse descriptive de l'activité « Mesure Continue du Glucose, p.26

P. Suivi-des, 46 3. Temps d'utilisation et pourcentage d'abandon, p.47

B. Tallant, R. , and M. , Department of Pediatrics

J. Michael and . Tansey, MD (I)

J. Cabbage, ); (3) Nemours Children's Clinic, C

D. M. Wilson, MD (I)

K. Caswell and A. , Department of Pediatrics

V. William and . Tamborlane, MD (I)

V. Bibliographie, The effect of intensive treatment of diabetes on the development and progression of longterm complications in insulin-dependent diabetes mellitus. The Diabetes Control and Complications Trial Research Group, N. Engl. J. Med, vol.1, issue.329, pp.977-986, 1993.

I. B. Hirsch, Realistic Expectations and Practical Use of Continuous Glucose Monitoring for the Endocrinologist, The Journal of Clinical Endocrinology & Metabolism, vol.94, issue.7, pp.2232-2238, 2009.
DOI : 10.1210/jc.2008-2625

S. Genay, J. Fulcrand, and B. Décaudin, Pompes à insuline et capteurs de glucose interstitiel, pp.25-35, 2012.

B. W. Bequette, Continuous Glucose Monitoring: Real-Time Algorithms for Calibration, Filtering, and Alarms, Journal of Diabetes Science and Technology, vol.4, issue.2, pp.404-418, 2010.
DOI : 10.1177/193229681000400222

S. Vaddiraju, D. J. Burgess, I. Tomazos, F. C. Jain, and F. Papadimitrakopoulos, Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises, Journal of Diabetes Science and Technology, vol.24, issue.9, pp.1540-1562, 2010.
DOI : 10.1016/0956-5663(92)85053-D

P. Agrawal, Usage and Effectiveness of the Low Glucose Suspend Feature of the Medtronic Paradigm Veo Insulin Pump, Journal of Diabetes Science and Technology, vol.11, issue.4, pp.1137-1141, 2011.
DOI : 10.1089/dia.2008.0032

Y. Reznik and M. Et-joubert, La mesure en continu du glucose : Quel impact sur l'équilibre glycémique? Quelles indications? Comment l'utiliser en pratique?, pp.107-122

S. H. Golden, Methods for Insulin Delivery and Glucose Monitoring: Comparative Effectiveness, pp.1-309, 2012.

D. Deiss, Improved Glycemic Control in Poorly Controlled Patients with Type 1 Diabetes Using Real-Time Continuous Glucose Monitoring, Diabetes Care, vol.29, issue.12, pp.2730-2732, 2006.
DOI : 10.2337/dc06-1134

O. Connell and M. A. , Glycaemic impact of patient-led use of sensor-guided pump therapy in type 1 diabetes: a randomised controlled trial, Diabetologia, vol.114, issue.7, pp.1250-1257, 2009.
DOI : 10.1007/s00125-009-1365-0

W. V. Tamborlane, Continuous glucose monitoring and intensive treatment of type 1 diabetes, N. Engl. J. Med, vol.359, pp.1464-1476, 2008.

T. Battelino, Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes, Diabetes Care, vol.34, issue.4
DOI : 10.2337/dc10-1989

J. Hermanides, Sensor-augmented pump therapy lowers HbA1c in suboptimally controlled Type???1 diabetes; a randomized controlled trial, Diabetic Medicine, vol.26, issue.10, pp.1158-1167, 2011.
DOI : 10.1111/j.1464-5491.2011.03256.x

R. M. Bergenstal, Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes, New England Journal of Medicine, vol.363, issue.4, pp.311-320, 2010.
DOI : 10.1056/NEJMoa1002853

J. Riveline, Assessment of Patient-Led or Physician-Driven Continuous Glucose Monitoring in Patients With Poorly Controlled Type 1 Diabetes Using Basal-Bolus Insulin Regimens: A 1-year multicenter study, Diabetes Care, vol.35, issue.5, pp.965-971, 2012.
DOI : 10.2337/dc11-2021

I. B. Hirsch and M. Brownlee, Should minimal blood glucose variability become the gold standard of glycemic control?, Journal of Diabetes and its Complications, vol.19, issue.3, pp.178-181, 2005.
DOI : 10.1016/j.jdiacomp.2004.10.001

P. Choudhary, Insulin Pump Therapy With Automated Insulin Suspension in Response to Hypoglycemia: Reduction in nocturnal hypoglycemia in those at greatest risk, Diabetes Care, vol.34, issue.9, pp.2023-2025, 2011.
DOI : 10.2337/dc10-2411

T. T. Ly, J. A. Nicholas, A. Retterath, E. A. Davis, and T. W. Jones, Analysis of Glucose Responses to Automated Insulin Suspension With Sensor-Augmented Pump Therapy, Diabetes Care, vol.35, issue.7, pp.10-2337, 2012.
DOI : 10.2337/dc12-0052

E. A. Ryan and J. Germsheid, Use of Continuous Glucose Monitoring System in the Management of Severe Hypoglycemia, Diabetes Technology & Therapeutics, vol.11, issue.10, pp.635-639, 2009.
DOI : 10.1089/dia.2009.0042

M. Tansey, Satisfaction with continuous glucose monitoring in adults and youths with Type???1 diabetes, Diabetic Medicine, vol.12, issue.9, pp.1118-1122, 2011.
DOI : 10.1111/j.1464-5491.2011.03368.x

R. R. Rubin and M. Peyrot, Treatment Satisfaction and Quality of Life for an Integrated Continuous Glucose Monitoring/Insulin Pump System Compared to Self-Monitoring plus an Insulin Pump, Journal of Diabetes Science and Technology, vol.32, issue.8, pp.1402-1410, 2009.
DOI : 10.1097/01.MLR.0000062554.74615.4C

A. P. Cemeroglu, Use of a real-time continuous glucose monitoring system in children and young adults on insulin pump therapy: patients' and caregivers' perception of benefit, Pediatric Diabetes, vol.7, issue.3, pp.182-187, 2010.
DOI : 10.1111/j.1399-5448.2009.00549.x

J. T. Markowitz, K. Pratt, J. Aggarwal, L. K. Volkening, and L. M. Laffel, Psychosocial Correlates of Continuous Glucose Monitoring Use in Youth and Adults with Type 1 Diabetes and Parents of Youth, Diabetes Technology & Therapeutics, vol.14, issue.6, pp.523-526, 2012.
DOI : 10.1089/dia.2011.0201

H. R. Murphy, Effectiveness of continuous glucose monitoring in pregnant women with diabetes: randomised clinical trial, BMJ, vol.337, issue.sep25 2, p.1680, 2008.
DOI : 10.1136/bmj.a1680

R. Chen, Continuous glucose monitoring for the evaluation and improved control of gestational diabetes mellitus, The Journal of Maternal-Fetal & Neonatal Medicine, vol.24, issue.2, pp.256-260, 2003.
DOI : 10.1080/jmf.14.4.256.260

Y. Yogev, Continuous Glucose Monitoring for the Evaluation of Gravid Women With Type 1 Diabetes Mellitus, Obstetrics & Gynecology, vol.101, issue.4, pp.633-638, 2003.
DOI : 10.1097/00006250-200304000-00005

K. K. Kestilä, U. U. Ekblad, and T. Rönnemaa, Continuous glucose monitoring versus selfmonitoring of blood glucose in the treatment of gestational diabetes mellitus, Diabetes Res. Clin

R. A. Vigersky, S. J. Fonda, M. Chellappa, M. S. Walker, and N. M. Ehrhardt, Short- and Long-Term Effects of Real-Time Continuous Glucose Monitoring in Patients With Type 2 Diabetes, Diabetes Care, vol.35, issue.1, pp.32-38, 2012.
DOI : 10.2337/dc11-1438

D. Poinsot, perso.univ-rennes1.fr 31. Lifetime benefits and costs of intensive therapy as practiced in the diabetes control and complications trial. The Diabetes Control and Complications Trial Research Group, statistiques pour statophobes, pp.1409-1415, 1996.

E. S. Huang, The Cost-Effectiveness of Continuous Glucose Monitoring in Type 1 Diabetes, Diabetes Care, vol.33, issue.6
DOI : 10.2337/dc09-2042

R. B. Mcqueen, S. L. Ellis, J. D. Campbell, K. V. Nair, and P. W. Sullivan, Cost-effectiveness of continuous glucose monitoring and intensive insulin therapy for type 1 diabetes, Cost Effectiveness and Resource Allocation, vol.9, issue.1, p.13, 2011.
DOI : 10.2337/diacare.28.3.617

R. S. Braithwaite, D. O. Meltzer, J. T. King, . Jr, D. Leslie et al., What does the value of modern medicine say about the $50,000 per quality-adjusted life-year decision rule? Med Care 46, pp.349-356, 2008.

J. H. Devries, Continuous glucose monitoring: coming of age?, European Journal of Endocrinology, vol.166, issue.1, pp.1-4, 2012.
DOI : 10.1530/EJE-10-1127

M. Peyrot and R. R. Rubin, Behavioral and Psychosocial Interventions in Diabetes: A conceptual review, Diabetes Care, vol.30, issue.10, pp.2433-2440, 2007.
DOI : 10.2337/dc07-1222

A. J. Jenkins, An Algorithm Guiding Patient Responses to Real-Time-Continuous Glucose Monitoring Improves Quality of Life, Diabetes Technology & Therapeutics, vol.13, issue.2, pp.105-109, 2011.
DOI : 10.1089/dia.2010.0139

B. Buckingham, Use of the DirecNet Applied Treatment Algorithm (DATA) for diabetes management with a real-time continuous glucose monitor (the FreeStyle Navigator), Pediatr Diabetes, vol.9, pp.142-147, 2008.

P. Schaepelynck, Advances in pump technology: insulin patch pumps, combined pumps and glucose sensors, and implanted pumps, Diabetes & Metabolism, vol.37, pp.85-93, 2011.
DOI : 10.1016/S1262-3636(11)70972-7

B. Kovatchev, Multinational Study of Subcutaneous Model-Predictive Closed-Loop Control in Type 1 Diabetes Mellitus: Summary of the Results, Journal of Diabetes Science and Technology, vol.2, issue.5, pp.1374-1381, 2010.
DOI : 10.1089/dia.2008.0138

R. Hovorka, Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial, The Lancet, vol.375, issue.9716, pp.743-751, 2010.
DOI : 10.1016/S0140-6736(09)61998-X