Prospective comparison of six non-invasive scores for the diagnosis of liver fibrosis in chronic hepatitis C, Journal of Hepatology, vol.46, issue.5, pp.775-82, 2007. ,
DOI : 10.1016/j.jhep.2006.12.013
URL : https://hal.archives-ouvertes.fr/inserm-00324953
Automation of the Hepascore and validation as a biochemical index of liver fibrosis in patients with chronic hepatitis C from the ANRS HC EP 23 Fibrostar cohort, Clinica Chimica Acta, vol.411, issue.1-2, pp.86-91, 2010. ,
DOI : 10.1016/j.cca.2009.10.011
Analytical variability of the Fibrotest proteins, Clinical Biochemistry, vol.38, issue.5, pp.473-481, 2005. ,
DOI : 10.1016/j.clinbiochem.2004.12.012
Diagnostic accuracy of the aspartate aminotransferase-to-platelet ratio index for the prediction of hepatitis C???related fibrosis: A systematic review, Hepatology, vol.26, issue.3, pp.912-933, 2007. ,
DOI : 10.1002/hep.21835
Diagnostic accuracy, reproducibility and robustness of fibrosis blood tests in chronic hepatitis C: A meta-analysis with individual data, Clinical Biochemistry, vol.41, issue.16-17, pp.16-171368, 2008. ,
DOI : 10.1016/j.clinbiochem.2008.06.020
URL : https://hal.archives-ouvertes.fr/inserm-00324933
Comparison of nine blood tests and transient elastography for liver fibrosis in chronic hepatitis C: The ANRS HCEP-23 study, Journal of Hepatology, vol.56, issue.1, pp.55-62, 2012. ,
DOI : 10.1016/j.jhep.2011.05.024
URL : https://hal.archives-ouvertes.fr/hal-00866960
Ultrasonographic diagnosis of hepatic fibrosis or cirrhosis, Journal of Hepatology, vol.30, issue.3, pp.472-480, 1999. ,
DOI : 10.1016/S0168-8278(99)80107-X
Correlation between ultrasonographic and pathologic diagnosis of liver fibrosis due to chronic virus hepatitis, World Journal of Gastroenterology, vol.12, issue.8 ,
DOI : 10.3748/wjg.v12.i8.1292
Comparison between ultrasonographic signs and the degree of portal hypertension in patients with cirrhosis, Gastrointestinal Radiology, vol.37, issue.1, pp.218-240, 1990. ,
DOI : 10.1007/BF01888780
Value of ultrasonography in the diagnosis of cirrhoses. Prospective study of 128 patients, J Radiol, vol.66, pp.8-9503, 1985. ,
Cirrhosis: diagnosis with sonographic study of the liver surface., Radiology, vol.172, issue.2, pp.389-92, 1989. ,
DOI : 10.1148/radiology.172.2.2526349
Sonographic measurements of the normal liver, spleen, pancreas, and portal vein., Radiology, vol.149, issue.2, pp.537-577, 1983. ,
DOI : 10.1148/radiology.149.2.6622701
Diagnosis of liver cirrhosis with US: receiver-operating characteristic analysis of multidimensional caudate lobe indexes., Radiology, vol.171, issue.2, pp.349-51, 1989. ,
DOI : 10.1148/radiology.171.2.2649915
Segment 4 (the quadrate lobe): a barometer of cirrhotic liver disease at US., Radiology, vol.206, issue.1, pp.157-60, 1998. ,
DOI : 10.1148/radiology.206.1.9423666
Sonographic evaluation of liver nodularity: Inspection of deep versus superficial surfaces of the liver, Journal of Clinical Ultrasound, vol.33, issue.7, pp.399-407, 2002. ,
DOI : 10.1002/jcu.10095
Interobserver concordance of echographic semiology in liver cirrhosis, Gastroenterol. Clin. Biol, vol.19, issue.3, pp.291-297, 1995. ,
Severe Liver Fibrosis or Cirrhosis: Accuracy of US for Detection???Analysis of 300 Cases, Radiology, vol.227, issue.1, pp.89-94, 2003. ,
DOI : 10.1148/radiol.2272020193
Sonographic evaluation of the anterior liver surface in chronic liver diseases using a 7.5-MHz annular-array transducer: Correlation with laparoscopic and histopathologic findings, Journal of Clinical Ultrasound, vol.72, issue.8, pp.393-400, 2003. ,
DOI : 10.1002/jcu.10195
Cirrhosis: Diagnosis by liver surface analysis with high-frequency ultrasound, Gastrointestinal Radiology, vol.18, issue.1, pp.74-82, 1992. ,
DOI : 10.1007/BF01888512
The diagnosis of cirrhosis by high resolution ultrasound of the liver surface., The British Journal of Radiology, vol.72, issue.853, pp.29-34, 1999. ,
DOI : 10.1259/bjr.72.853.10341686
Ultrasound evaluation of the fibrosis stage in chronic liver disease by the simultaneous use of low and high frequency probes, The British Journal of Radiology, vol.78, issue.927, pp.189-97, 2005. ,
DOI : 10.1259/bjr/75208448
Computer-assisted Quantitative Analysis of Liver Surface Irregularities with High-Resolution Ultrasound: A Noninvasive Method for Significant Fibrosis Diagnosis, RSNA 96th Scientific Assembly and Annual Meeting, 2010. ,
Evaluation quantitative par un logiciel pour le diagnostic de fibrose significative en échographie, 2010. ,
Diagnostic efficacy of an ultrasound quantitative method in a rat model of experimental liver fibrosis, Zhonghua Gan Zang Bing Za Zhi, vol.20, issue.2, pp.122-127, 2012. ,
Deviations from Rayleigh statistics in ultrasonic speckle. Ultrason Imaging, pp.81-90, 1988. ,
A pilot approach for quantitative assessment of liver fibrosis using ultrasound: preliminary results in 79 cases, Journal of Hepatology, vol.44, issue.1, pp.68-75, 2006. ,
DOI : 10.1016/j.jhep.2005.08.009
Diagnostic accuracy, reproducibility and robustness of fibrosis blood tests in chronic hepatitis C: A meta-analysis with individual data, Clinical Biochemistry, vol.41, issue.16-17, pp.16-171368, 2008. ,
DOI : 10.1016/j.clinbiochem.2008.06.020
URL : https://hal.archives-ouvertes.fr/inserm-00324933
Sources of variability in histological scoring of chronic viral hepatitis, Hepatology, vol.20, issue.4Pt2, pp.257-264, 2005. ,
DOI : 10.1002/hep.20535
Meta-analyses of FibroTest diagnostic value in chronic liver disease, BMC Gastroenterology, vol.46, issue.1, p.40, 2007. ,
DOI : 10.1016/j.jhep.2006.12.002
A novel panel of blood markers to assess the degree of liver fibrosis, Hepatology, vol.39, issue.6, pp.1373-1381, 2005. ,
DOI : 10.1002/hep.20935
Diagnostic accuracy, reproducibility and robustness of fibrosis blood tests in chronic hepatitis C: A meta-analysis with individual data, Clinical Biochemistry, vol.41, issue.16-17, pp.1368-1376, 2008. ,
DOI : 10.1016/j.clinbiochem.2008.06.020
URL : https://hal.archives-ouvertes.fr/inserm-00324933
Int??r??t de l?????lastom??trie (FibroScan??) pour l?????valuation non invasive de la fibrose h??patique, Gastroent??rologie Clinique et Biologique, vol.31, issue.5, pp.524-530, 2007. ,
DOI : 10.1016/S0399-8320(07)89422-X
Performance of Transient Elastography for the Staging of Liver Fibrosis: A Meta-Analysis, Gastroenterology, vol.134, issue.4, pp.960-974, 2008. ,
DOI : 10.1053/j.gastro.2008.01.034
Prediction of oesophageal varices in hepatic cirrhosis by simple serum non-invasive markers: Results of a multicenter, large-scale study, Journal of Hepatology, vol.53, issue.4, pp.630-638, 2010. ,
DOI : 10.1016/j.jhep.2010.04.019
Pitfalls of liver stiffness measurement: A 5-year prospective study of 13,369 examinations, Hepatology, vol.46, pp.828-835, 2010. ,
DOI : 10.1002/hep.23425
Factors of accuracy of transient elastography (fibroscan) for the diagnosis of liver fibrosis in chronic hepatitis C, Hepatology, vol.3, issue.4, pp.1083-1089, 2009. ,
DOI : 10.1002/hep.22748
Diagnostic accuracy of FibroScan and comparison to liver fibrosis biomarkers in chronic viral hepatitis: A multicenter prospective study (the FIBROSTIC study), Journal of Hepatology, vol.53, issue.6, pp.1013-1021, 2010. ,
DOI : 10.1016/j.jhep.2010.05.035
Liver biopsy: The best, not the gold standard, Journal of Hepatology, vol.50, issue.1, pp.1-3, 2009. ,
DOI : 10.1016/j.jhep.2008.10.014
Magnetic Resonance Elastography for the Noninvasive Staging of Liver Fibrosis, Gastroenterology, vol.135, issue.1, pp.32-40, 2008. ,
DOI : 10.1053/j.gastro.2008.03.076
Comparison of nine blood tests and transient elastography for liver fibrosis in chronic hepatitis C: The ANRS HCEP-23 study, Journal of Hepatology, vol.56, issue.1 ,
DOI : 10.1016/j.jhep.2011.05.024
URL : https://hal.archives-ouvertes.fr/hal-00866960
Computer-assisted Quantitative Analysis of Liver Surface Irregularities with High-Resolution Ultrasound: A Noninvasive Method for Significant Fibrosis Diagnosis ,
Evaluation quantitative par un logiciel pour le diagnostic de fibrose significative en échographie, 2010. ,
Quantitative Viscoelasticity Mapping of Human Liver Using Supersonic Shear Imaging: Preliminary In Vivo Feasability Study, Ultrasound in Medicine & Biology, vol.35, issue.2, pp.219-229, 2009. ,
DOI : 10.1016/j.ultrasmedbio.2008.08.018
Severe Liver Fibrosis or Cirrhosis: Accuracy of US for Detection???Analysis of 300 Cases, Radiology, vol.227, issue.1, pp.89-94, 2003. ,
DOI : 10.1148/radiol.2272020193
Comparing the Areas under Two or More Correlated Receiver Operating Characteristic Curves: A Nonparametric Approach, Biometrics, vol.44, issue.3, pp.837-845, 1988. ,
DOI : 10.2307/2531595
Robust Sample Size Projections for Estimating and Comparing the area under ROC Curves ,
Bounding sample size projections for the area under a ROC curve, Journal of Statistical Planning and Inference, vol.139, issue.3, pp.711-721, 2009. ,
DOI : 10.1016/j.jspi.2007.09.015
Acoustic Radiation Force Impulse (ARFI): a new ultrasonographic technology for the widespread non-invasive diagnosis of liver fibrosis, Eur J Gastroenterol Hepatol, 2010. ,
Liver Fibrosis in Viral Hepatitis: Noninvasive Assessment with Acoustic Radiation Force Impulse Imaging versus Transient Elastography, Radiology, vol.252, issue.2, pp.595-604, 2009. ,
DOI : 10.1148/radiol.2523081928
217 ACOUSTIC RADIATION FORCE IMAGING (ARFI) AS A NEW METHOD OF ULTRASONOGRAPHIC ELASTOGRAPHY ALLOWS ACCURATE AND FLEXIBLE ASSESSMENT OF LIVER STIFFNESS, Journal of Hepatology, vol.50, issue.1, p.88, 2009. ,
DOI : 10.1016/S0168-8278(09)60219-1
Evaluation of acoustic radiation force impulse elastography for fibrosis staging of chronic liver disease: a pilot study, Liver International, vol.30, issue.4, 2009. ,
DOI : 10.1111/j.1478-3231.2009.02130.x
989 NEW FIBROSCAN PROBE FOR OBESE PATIENTS. A PILOT STUDY OF FEASIBILITY AND PERFORMANCES IN PATIENTS WITH BMI ??? 30 kg/m2, Journal of Hepatology, vol.50, p.359, 2009. ,
DOI : 10.1016/S0168-8278(09)60991-0
Reproducibility of Liver Stiffness Measurement by Ultrasonographic Elastometry, Clinical Gastroenterology and Hepatology, vol.6, issue.11, pp.1263-1269, 2008. ,
DOI : 10.1016/j.cgh.2008.07.006
URL : https://hal.archives-ouvertes.fr/hal-01390733