R. Iorio, W. Robb, W. Healy, D. Berry, W. Hozack et al., Orthopaedic Surgeon Workforce and Volume Assessment for Total Hip and Knee Replacement in the United States: Preparing for an Epidemic, The Journal of Bone and Joint Surgery-American Volume, vol.90, issue.7, pp.1598-605, 2008.
DOI : 10.2106/JBJS.H.00067

J. Insall, R. Binazzi, M. Soudry, and L. Mestriner, Total Knee Arthroplasty, Clinical Orthopaedics and Related Research, vol.&NA;, issue.192
DOI : 10.1097/00003086-198501000-00003

P. Lotke and M. Ecker, Influence of positioning of prosthesis in total knee replacement, The Journal of Bone & Joint Surgery, vol.59, issue.1
DOI : 10.2106/00004623-197759010-00013

M. Ritter, P. Faris, E. Keating, and J. Meding, Postoperative Alignment of Total Knee Replacement Its Effect on Survival, Clinical Orthopaedics and Related Research, vol.&NA;, issue.299, pp.153-159, 1994.
DOI : 10.1097/00003086-199402000-00021

R. Jeffery, R. Morris, and R. Denham, Coronal alignment after total knee replacement

D. Fang, M. Ritter, and K. Davis, Coronal Alignment in Total Knee Arthroplasty, The Journal of Arthroplasty, vol.24, issue.6, pp.39-43, 2009.
DOI : 10.1016/j.arth.2009.04.034

P. Kumar and L. Dorr, Severe malalignment and soft-tissue imbalance in total knee arthroplasty, Am J Knee Surg, vol.10, issue.1, pp.36-41, 1997.

S. Chauhan, R. Scott, W. Breidahl, and R. Beaver, Computer-assisted knee arthroplasty versus a conventional jig-based technique, The Journal of Bone and Joint Surgery, vol.86, issue.3, pp.372-379, 2004.
DOI : 10.1302/0301-620X.86B3.14643

J. Mason, T. Fehring, R. Estok, D. Banel, and K. Fahrbach, Meta-Analysis of Alignment Outcomes in Computer-Assisted Total Knee Arthroplasty Surgery, The Journal of Arthroplasty, vol.22, issue.8, 2007.
DOI : 10.1016/j.arth.2007.08.001

A. Lombardi, . Jr, K. Berend, and J. Adams, Patient-Specific Approach in Total Knee Arthroplasty, Orthopedics, vol.31, issue.9, pp.927-957, 2008.
DOI : 10.3928/01477447-20080901-21

Y. Kim, J. Kim, Y. Choi, and O. Kwon, Computer-Assisted Surgical Navigation Does Not Improve the Alignment and Orientation of the Components in Total Knee Arthroplasty, The Journal of Bone and Joint Surgery-American Volume, vol.91, issue.1, pp.14-23, 2009.
DOI : 10.2106/JBJS.G.01700

M. Sparmann, B. Wolke, H. Czupalla, D. Banzer, and A. Zink, Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study, J Bone Joint Surg Br, vol.85, issue.6, pp.830-835, 2003.

!. , !. Victor, J. Hoste, D. Noble, J. Jr et al., Image-based computer-assisted total knee arthroplasty leads to lower variability in coronal alignment The value of patient-matched instrumentation in total knee arthroplasty, Clin. Orthop. Relat. Res. J Arthroplasty, vol.27, issue.1, pp.131-140, 2004.

V. Ng, J. Declaire, K. Berend, B. Gulick, A. Lombardi et al., Improved Accuracy of Alignment With Patient-specific Positioning Guides Compared With Manual Instrumentation in TKA, Clinical Orthopaedics and Related Research??, vol.71, issue.1, pp.99-107, 2012.
DOI : 10.1007/s11999-011-1996-6

B. Klatt, N. Goyal, M. Austin, and W. Hozack, Custom-Fit Total Knee Arthroplasty (OtisKnee) Results in Malalignment, The Journal of Arthroplasty, vol.23, issue.1, pp.26-35, 2008.
DOI : 10.1016/j.arth.2007.10.001

R. Nunley, B. Ellison, J. Zhu, E. Ruh, S. Howell et al., Do Patient-specific Guides Improve Coronal Alignment in Total Knee Arthroplasty?, Clinical Orthopaedics and Related Research??, vol.24, issue.suppl 2, p.2012
DOI : 10.1007/s11999-011-2222-2

J. Victor, J. Dujardin, H. Vandenneucker, N. Arnout, J. Bellemans et al., Patient-specific Guides Do Not Improve Accuracy in Total Knee Arthroplasty: A Prospective Randomized Controlled Trial Functional and radiographic short-term outcome evaluation of the visionaire system, a patient-matched instrumentation system for total knee arthroplasty, Clin. Orthop. Relat. Res. J Arthroplasty, vol.20, 2013.

K. Chareancholvanich, R. Narkbunnam, and C. Pornrattanamaneewong, A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement, The Bone & Joint Journal, vol.95, issue.3, pp.964-70
DOI : 10.1302/0301-620X.95B3.29903

B. Boonen, M. Schotanus, and N. Kort, Preliminary experience with the patient-specific templating total knee arthroplasty, Acta Orthopaedica, vol.38, issue.2, pp.387-93
DOI : 10.1016/j.arth.2007.08.001

B. Stronach, C. Pelt, J. Erickson, and C. Peters, Patient-specific Total Knee Arthroplasty Required Frequent Surgeon-directed Changes, Clinical Orthopaedics and Related Research??, vol.20, issue.1, pp.169-74, 2013.
DOI : 10.1007/s11999-012-2573-3

URL : http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3528928

M. Pietsch, O. Djahani, C. Zweiger, F. Plattner, R. Radl et al., Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes, Knee Surgery, Sports Traumatology, Arthroscopy, vol.26, issue.Suppl 6, 2012.
DOI : 10.1007/s00167-012-2284-z

T. Heyse and C. Tibesku, Improved femoral component rotation in TKA using patientspecific instrumentation. Knee, 2012.

D. White, K. Chelule, and B. Seedhom, Accuracy of MRI vs CT imaging with particular reference to patient specific templates for total knee replacement surgery, The International Journal of Medical Robotics and Computer Assisted Surgery, vol.15, issue.5, pp.224-255, 2008.
DOI : 10.1002/rcs.201

C. Tibesku, P. Hofer, W. Portegies, C. Ruys, and P. Fennema, Benefits of using customized instrumentation in total knee arthroplasty: results from an activity-based costing model, Archives of Orthopaedic and Trauma Surgery, vol.31, issue.1, pp.405-416, 2013.
DOI : 10.1007/s00402-012-1667-4

M. Hafez, K. Chelule, B. Seedhom, and K. Sherman, Computer-assisted Total Knee Arthroplasty Using Patient-specific Templating, Clinical Orthopaedics and Related Research, vol.38, issue.&NA;, pp.184-92, 2006.
DOI : 10.1097/01.blo.0000201148.06454.ef

D. Eckhoff, J. Bach, V. Spitzer, K. Reinig, M. Bagur et al., Threedimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality, J Bone Joint Surg Am, vol.87, issue.2, pp.71-80, 2005.

D. Eckhoff, C. Hogan, L. Dimatteo, M. Robinson, and J. Bach, Difference between the epicondylar and cylindrical axis of the knee, Clin. Orthop. Relat. Res, vol.461, pp.238-282, 2007.

S. Parratte, M. Pagnano, R. Trousdale, and D. Berry, Effect of Postoperative Mechanical Axis Alignment on the Fifteen-Year Survival of Modern, Cemented Total Knee Replacements, The Journal of Bone and Joint Surgery-American Volume, vol.92, issue.12, pp.2143-2152, 2010.
DOI : 10.2106/JBJS.I.01398

S. Howell, K. Kuznik, M. Hull, and R. Siston, Results of an Initial Experience with Custom-Fit Positioning Total Knee Arthroplasty in a Series of 48 Patients, Orthopedics, vol.31, issue.9, 2008.
DOI : 10.3928/01477447-20080901-15

B. Spencer, M. Mont, M. Mcgrath, B. Boyd, and M. Mitrick, Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment, International Orthopaedics, vol.88, issue.Suppl 4, pp.1571-1576, 2009.
DOI : 10.1007/s00264-008-0693-x

URL : http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2899191

H. Dossett, G. Swartz, N. Estrada, G. Lefevre, and B. Kwasman, Kinematically Versus Mechanically Aligned Total Knee Arthroplasty, Orthopedics, vol.35, issue.2, pp.160-169, 2012.
DOI : 10.3928/01477447-20120123-04

S. Howell, S. Howell, K. Kuznik, J. Cohen, and M. Hull, Does A Kinematically Aligned Total Knee Arthroplasty Restore Function Without Failure Regardless of Alignment Category?, Clinical Orthopaedics and Related Research??, vol.92, issue.suppl 3
DOI : 10.1007/s11999-012-2613-z

S. Mayer, K. Hug, B. Hansen, and M. Bolognesi, Total Knee Arthroplasty in Osteopetrosis Using Patient-Specific Instrumentation, The Journal of Arthroplasty, vol.27, issue.8, pp.1580-1581
DOI : 10.1016/j.arth.2011.12.007

B. Kerens, B. Boonen, M. Schotanus, and N. Kort, Patient-specific guide for revision of medial unicondylar knee arthroplasty to total knee arthroplasty, Acta Orthopaedica, vol.11, issue.5, p.2013
DOI : 10.3109/17453674.2013.785908

Y. Gan, D. Xu, S. Lu, and J. Ding, Novel patient-specific navigational template for total knee arthroplasty, Computer Aided Surgery, vol.71, issue.6, pp.288-97, 2011.
DOI : 10.1054/arth.2001.21456

K. Bali, P. Walker, and W. Bruce, Custom-Fit Total Knee Arthroplasty: Our Initial Experience in 32 Knees, The Journal of Arthroplasty, vol.27, issue.6, pp.1149-54
DOI : 10.1016/j.arth.2011.12.006

F. Conteduca, R. Iorio, D. Mazza, L. Caperna, G. Bolle et al., Evaluation of the accuracy of a patient-specific instrumentation by navigation Knee Surg Sports Traumatol Arthrosc The Use of Patient-Specific Intra-Operative Guides for TKA. Archives of Clinical and Experimental Surgery (ACES). 2012;1. 43. Daniilidis K, Tibesku CO. Frontal plane alignment after total knee arthroplasty using patient-specific instruments, Int Orthop, vol.4237, issue.1, pp.201345-50, 2012.

S. Lustig, C. Scholes, S. Oussedik, V. Kinzel, M. Coolican et al., Unsatisfactory accuracy as determined by computer navigation of VISIONAIRE patientspecific instrumentation for total knee arthroplasty Patient specific cutting blocks are currently of no proven value, J Arthroplasty. Barrack RL J Bone Joint Surg Br, vol.28, issue.3, pp.469-73, 2012.

F. Conteduca, R. Iorio, D. Mazza, L. Caperna, G. Bolle et al., Are MRIbased , patient matched cutting jigs as accurate as the tibial guides? Int Orthop, 2012.

M. Yaffe, A. Patel, M. Coy, B. Luo, M. Cayo et al., Component sizing in total knee arthroplasty: patient-specific guides vs. computer-assisted navigation, Biomedizinische Technik/Biomedical Engineering, vol.57, issue.4, pp.277-82, 2012.
DOI : 10.1515/bmt-2011-0093

D. Nam, P. Maher, B. Rebolledo, D. Nawabi, A. Mclawhorn et al., Patient specific cutting guides versus an imageless, computer-assisted surgery system in total knee arthroplasty, The Knee, vol.20, issue.4, pp.263-270, 2013.
DOI : 10.1016/j.knee.2012.12.009