P. Kamina, Anatomie clinique Organes urinaires et génitaux pelvis Paris : Maloine, p.258, 2008.

J. Lansac, C. Bergers, and . Obstétrique, Paris : Masson, p.147, 2003.

M. Tournaire, Déclenchement spontané du travail, p.52, 1991.

M. Drissen, Y. Blumental, and . Gynecologie-obstetrique, Paris : Estem, p.56, 2009.

J. Mccoshen, H. Tulloch, and K. Johnson, Umbilical cord is the major source of prostaglandin E2 in the gestational sac during term labor, American Journal of Obstetrics and Gynecology, vol.160, issue.4, pp.973-978, 1989.
DOI : 10.1016/0002-9378(89)90319-0

J. Orsini and J. Pellet, Introduction biologique à la physiologie. 2 ème édition Liège : Breal, p.45, 2005.

M. Berland, Physiologie du déclenchement spontané du travail. Lyon : Editions Scientifiques et Médicales Elsevier, p.24, 1995.

W. Ganong, Physiologie Medicale. 2eme édition, p.424, 2005.

R. Smith and R. Nicholson, Corticotrophin releasing hormone and the timing of birth, Frontiers in Bioscience, vol.12, issue.1
DOI : 10.2741/2113

A. Assus and J. Cuenat, Etude théorique des tensions intramurales se manifestant dans les différentes régions du muscle utérin en fin de grossesse, Gynecol Obstet, vol.65, issue.10, pp.161-170, 1966.

J. I. Hamberg and . Fondamentale, Paris : Estem ; 1999, p.52

J. Joulin, Traite Complet d'accouchements Anatomie et Physiologie

H. Philippe, Déclenchement de l'accouchement Conférence de consensus [consulté le 19 Disponible à partir de : URL : <http, 2012.

H. Autorité and D. Santé, Déclenchement artificiel du travail à partir de 37 semaines d'aménorrhée 2008. [consulté le 19 Disponible à partir de : URL : <http://has-sante

V. Berghella, R. Rogers, and K. Lescale, Stripping of Membranes as a Safe Method to Reduce Prolonged Pregnancies, Obstetrics & Gynecology, vol.87, issue.6, pp.927-958, 1996.
DOI : 10.1016/0029-7844(96)00046-4

L. Foong, K. Vanaja, G. Tan, and S. Chua, Membranes sweeping in conjunction with induction, Obstet Gynecol, vol.96, issue.4, pp.539-581, 2000.

Z. Vaknin, Y. Kurzweil, and D. Sherman, Foley catheter balloon vs locally applied prostaglandins for cervical ripening and labor induction: a systematic review and metaanalysis, American Journal of Obstetrics and Gynecology, vol.203, issue.5, pp.418-447, 2010.
DOI : 10.1016/j.ajog.2010.04.038

M. Jozwiak, K. Rengerink, M. Benthem, E. Van-beek, and I. De-graaf, Foley catheter versus vaginal prostaglandin E2 gel for induction of labour at term (PROBAAT trial): an open-label, randomised controlled trial, The Lancet, vol.378, issue.9809, pp.2095-103, 2011.
DOI : 10.1016/S0140-6736(11)61484-0

C. Joan, Le déclenchement à terme du travail Directives cliniques de la SOGC N°107, Am J Obstet Gynecol Can, vol.23, issue.8, pp.729-770, 2001.

C. Duquesne, Le score de Bishop : étude de sa valeur prédictive. La revue Sage- Femme Elsevier, pp.157-162, 2004.

J. Oleszczuk, Effectiveness of intracervical catheter as a labor preinduction method

J. Atad, M. Hallak, Y. Ben-david, R. Auslender, and H. Abramovici, Ripening and dilatation of the unfavourable cervix for induction of labour by a double balloon device: experience with 250 cases, BJOG: An International Journal of Obstetrics and Gynaecology, vol.26, issue.1, pp.29-31, 1997.
DOI : 10.1016/0028-2243(89)90210-4

E. Mei-dan, A. Walfish, S. Suarez-easton, and M. Hallak, Comparison of two mechanical devices for cervical ripening: a prospective quasi-randomized trial, The Journal of Maternal-Fetal & Neonatal Medicine, vol.87, issue.6, pp.723-730, 2012.
DOI : 10.1111/j.1471-0528.2009.02279.x

M. Jonsson, C. Hellgren, E. Wiberg-itzel, and H. Akerud, Assessment of pain in women randomly allocated to speculum or digital insertion of the Foley catheter for induction of labor, Acta Obstetricia et Gynecologica Scandinavica, vol.114, issue.2 Pt 1, pp.997-1004, 2011.
DOI : 10.1111/j.1600-0412.2011.01197.x

K. Keeton, Methods of induction of labour : a systematic review, BMC Pregnacy Childbirth, vol.11, pp.84-85, 2011.

T. Yamada, S. Kataoka, M. Takeda, and T. Kojima, Umbilical cord presentation after use of a trans-cervical balloon catheter, Journal of Obstetrics and Gynaecology Research, vol.16, issue.3, pp.36-37, 2010.
DOI : 10.1111/j.1447-0756.2012.02008.x

H. Contreras, A comparative trual of labor induction with misoprostol versus oxytocin

M. Keirse, Natural Prostaglandins for Induction of Labor and Preinduction Cervical Ripening, Clinical Obstetrics and Gynecology, vol.49, issue.3, pp.609-635, 2006.
DOI : 10.1097/00003081-200609000-00020

F. Ziyauddin, S. Hakim, and S. Beriwal, The transcervical foley catheter versus the vaginal protaglandin E2 gel in induction of labour in a previous one caesarean section : a clinical study, J Clin Diagn Res, vol.7, issue.351, pp.140-143, 2013.

J. Oleszczuk, Effectiveness of intracervical catheter as a labor preinduction method

S. Niromanesh, A. Mosavi-jarrahi, and F. Samkhiniani, Intracervical Foley catheter balloon vs. prostaglandin in preinduction cervical ripening, International Journal of Gynecology & Obstetrics, vol.46, issue.1, pp.23-30, 2003.
DOI : 10.1016/S0020-7292(02)00392-2

S. Onge and C. G. , Preinduction cervical ripening: A comparison of intracervical prostaglandin E2 gel versus the Foley catheter, American Journal of Obstetrics and Gynecology, vol.172, issue.2, pp.687-90, 1995.
DOI : 10.1016/0002-9378(95)90594-4

R. Dalui, V. Suri, P. Ray, and I. Gupta, Comparison of extraamniotic Foley catheter and intracervical protaglandin E gel for preinduction cervical ripening, Int J Gyaecol Obstet, vol.84, issue.394, pp.362-369, 2005.

D. Sherman, E. Frenkel, J. Tovbin, S. Arielis, E. Caspri et al., Ripening of the unfavorable cervix with extraamniotic catheter balloon :clinical experience and review

A. Henry, A. Madan, R. Reich, and S. Tracy, Outpatient Foley catheter versus inpatient prostaglandin E2 gel for induction of labour: a randomised trial, BMC Pregnancy and Childbirth, vol.117, issue.2, pp.25-26, 2013.
DOI : 10.1111/j.1471-0528.2010.02611.x

A. Sciscione, M. Muench, M. Pollock, T. Jenkins, J. Tildon-burton et al., Transcervical Foley catheter for preinduction cervical ripening in an outpatient versus inpatient setting, Obstet Gynecol, vol.98, issue.5Pt1, pp.751-757, 2001.

R. D. St-onge and G. Connors, Preinduction cervical ripening: A comparison of intracervical prostaglandin E2 gel versus the Foley catheter, American Journal of Obstetrics and Gynecology, vol.172, issue.2, pp.687-90, 1995.
DOI : 10.1016/0002-9378(95)90594-4

E. Bujold, S. Blackwell, and R. Gauthier, Cervical Ripening With Transcervical Foley Catheter and the Risk of Uterine Rupture, Obstetrics & Gynecology, vol.103, issue.1, pp.18-23, 2004.
DOI : 10.1097/01.AOG.0000109148.23082.C1

S. Siddiqui, N. Zuberi, A. Zafar, and R. Qureshi, Increased risk of cervical canal