B. Capolaghi, M. Moulsma, N. Houdret, and F. Baud, Stratégies analytiques en toxicologie d'ugeee, A Toiol Aal, pp.7-281

B. Chousterman, D. Payen, B. Mégarbane, and O. Laprévote, ??l??ments de chromatographie et de spectrom??trie de masse ?? l???usage des cliniciens, R??animation, vol.19, issue.6, pp.593-596, 2010.
DOI : 10.1016/j.reaurg.2010.05.001

V. Viette, M. Fathi, S. Rudaz, D. Hochstrasser, and J. Veuthey, Current role of liquid chromatography coupled to mass spectrometry in clinical toxicology screening methods, Clinical Chemistry and Laboratory Medicine, vol.49, issue.7, 2011.
DOI : 10.1515/CCLM.2011.182

F. Peters, Recent advances of liquid chromatography???(tandem) mass spectrometry in clinical and forensic toxicology, Clinical Biochemistry, vol.44, issue.1, pp.54-65, 2011.
DOI : 10.1016/j.clinbiochem.2010.08.008

B. Mégarbane, L. Donetti, T. Blanc, G. Chéron, and F. Jacobs, Intoxications graves par??m??dicaments et??substances illicites en??r??animation, R??animation, vol.15, issue.5, pp.332-342, 2006.
DOI : 10.1016/j.reaurg.2006.07.006

P. Nisse, Le screening toxicologique aux urgences, Congrès Urgences, vol.133, issue.45, 2010.

M. Bartoli, C. Berny, B. Capolaghi, V. Danel, A. Delahaye et al., Recommandations pour la pesiptio, la alisatio et l'iteeptatio des eeaees de iologie diale das le cadre des intoxications graves. Immuno-Anal Biol Spécialisée, 2013.

M. Tenenbein, Do you really need that emergency drug screen?, Clinical Toxicology, vol.40, issue.4, pp.286-291, 2009.
DOI : 10.1373/49.3.357

A. Kellermann, S. Fihn, J. Logerfo, and M. Copass, Impact of drug screening in suspected overdose, Annals of Emergency Medicine, vol.16, issue.11, pp.1206-1216, 1987.
DOI : 10.1016/S0196-0644(87)80225-1

J. Mahoney, P. Gross, T. Stern, B. Browne, M. Pollack et al., Quantitative serum toxic screening in the management of suspected drug overdose, The American Journal of Emergency Medicine, vol.8, issue.1, pp.16-22, 1990.
DOI : 10.1016/0735-6757(90)90287-A

A. Fabbri, G. Marchesini, A. Morselli-labate, S. Ruggeri, M. Fallani et al., Comprehensive drug screening in decision making of patients attending the emergency department for suspected drug overdose, Emergency Medicine Journal, vol.20, issue.1, pp.25-33, 2003.
DOI : 10.1136/emj.20.1.25

F. Adnet, S. Atout, M. Galinski, and F. Lapostolle, ??volution des??intoxications m??dicamenteuses volontaires en??France, R??animation, vol.14, issue.8, pp.721-726, 2005.
DOI : 10.1016/j.reaurg.2005.10.023

M. Mohaad, N. Veeeeie, D. Pateeo, and B. Beeeot, Evaluatio d'u potoole visat à diiuee la recherche des toxiques dans la prise en charge des intoxications médicamenteuses volontaires vues aux urgences: Evaluation of a protocol designed to optimize toxicological tests after voluntary self-poisoning, J Eur Urgences, vol.18, issue.1, pp.15-24, 2005.

A. Tracqui, P. Kintz, and P. Mangin, Systematic Toxicological Analysis Using HPLC/DAD, Journal of Forensic Sciences, vol.40, issue.2, pp.254-262, 1995.
DOI : 10.1520/JFS15353J

G. Szymanski, M. Bartoli, and N. Allibe-sigoii, Balofe : popositio d'ue teehiue d'idetifiatio et de dosage apide. 20ème Congrès SFTA Chambéry Fr, 2012.

A. Turcant, A. Premel-cabic, A. Cailleux, and P. Allain, Toxicological screening of drugs by microbore high-performance liquid chromatography with photodiode-array detection and ultraviolet spectral library searches, Clin Chem, vol.37, issue.7, pp.1210-1215, 1991.

N. Allibe-signorini, S. Berard, F. Vincent, G. Bessard, L. Barret et al., Int??r??t d'un logiciel de d??convolution (AMDIS) et d'une d??tection SIM/SCAN pour le screening toxicologique par CPG-SM, Annales de Toxicologie Analytique, vol.20, issue.2, pp.57-65, 2009.
DOI : 10.1051/ata/2009001

K. Pfleger, H. Maurer, and A. Weber, Mass Spectral and GC Data of Drugs, Poisons, Pesticides, Pollutants and Their Metabolites, 2002.

H. Maurer, Identification and differentiation of barbiturates, other sedative-hypnotics and their metabolites in urine integrated in a general screening procedure using computerized gas chromatography-mass spectrometry, Journal of Chromatography B: Biomedical Sciences and Applications, vol.530, issue.2, pp.307-326, 1990.
DOI : 10.1016/S0378-4347(00)82334-8

F. Peters, J. Jung, T. Kraemer, and H. Maurer, Fast, Simple, and Validated Gas Chromatographic-Mass Spectrometric Assay for Quantification of Drugs Relevant to Diagnosis of Brain Death in Human Blood Plasma Samples, Therapeutic Drug Monitoring, vol.27, issue.3, pp.334-344, 2005.
DOI : 10.1097/01.ftd.0000158079.53577.46

H. Maurer, Screening Procedures for Simultaneous Detection of Several Drug Classes Used for High Throughput Toxicological Analyses and Doping Control. A Review, Combinatorial Chemistry & High Throughput Screening, vol.3, issue.6, pp.467-480, 2000.
DOI : 10.2174/1386207003331355

H. Maurer and F. Peters, Toward High-Throughput Drug Screening Using Mass Spectrometry, Therapeutic Drug Monitoring, vol.27, issue.6, pp.686-688, 2005.
DOI : 10.1097/01.ftd.0000180224.19384.f0

J. Gross, Mass Spectrometry: A Textbook, 2011.

S. Dresen, N. Ferreirós, H. Gnann, R. Zimmermann, and W. Weinmann, Detection and identification of 700 drugs by multi-target screening with a 3200 Q TRAP?? LC-MS/MS system and library searching, Analytical and Bioanalytical Chemistry, vol.49, issue.7, pp.2425-2434, 2010.
DOI : 10.1007/s00216-010-3485-2

C. Mueller, W. Weinmann, S. Dresen, A. Schreiber, and M. Gergov, Development of a multi-target screening analysis for 301 drugs using a QTrap liquid chromatography/tandem mass spectrometry system and automated library searching, Rapid Communications in Mass Spectrometry, vol.773, issue.10, pp.1332-1338, 2005.
DOI : 10.1002/rcm.1934

S. Dresen, M. Gergov, L. Politi, C. Halter, and W. Weinmann, ESI-MS/MS library of 1,253 compounds for application in forensic and clinical toxicology, Analytical and Bioanalytical Chemistry, vol.22, issue.12, pp.2521-2526, 2009.
DOI : 10.1007/s00216-009-3084-2

R. Mylonas, Y. Mauron, A. Masselot, P. Binz, N. Budin et al., X-Rank: A Robust Algorithm for Small Molecule Identification Using Tandem Mass Spectrometry, Analytical Chemistry, vol.81, issue.18, pp.7604-7610, 2009.
DOI : 10.1021/ac900954d

L. M. , M. S. , M. M. , P. G. Perrin-m, and P. J. , Aide à la validation des méthodes en Toxicologie et Suivi Thérapeutique Pharmacologique Help for validation of analytical procedures in Toxicology and Therapeutic Drug Monitoring, 2005.

H. Liu, R. Liu, H. Ho, and D. Lin, Development of an Information-Rich LC???MS/MS Database for the Analysis of Drugs in Postmortem Specimens, Analytical Chemistry, vol.81, issue.21, pp.9002-9011, 2009.
DOI : 10.1021/ac901599d

S. Dulaurent, C. Moesch, P. Marquet, J. Gaulier, and G. Lachâtre, Screening of pesticides in blood with liquid chromatography???linear ion trap mass spectrometry, Analytical and Bioanalytical Chemistry, vol.29, issue.6, pp.2235-2249, 2010.
DOI : 10.1007/s00216-009-3443-z

H. Lee, C. Ho, Y. Iu, P. Lai, C. Shek et al., Development of a broad toxicological screening technique for urine using ultra-performance liquid chromatography and time-of-flight mass spectrometry, Analytica Chimica Acta, vol.649, issue.1, pp.80-90, 2009.
DOI : 10.1016/j.aca.2009.06.068

A. Polettini, R. Gottardo, J. Pascali, and F. Tagliaro, Implementation and Performance Evaluation of a Database of Chemical Formulas for the Screening of Pharmaco/Toxicologically Relevant Compounds in Biological Samples Using Electrospray Ionization-Time-of-Flight Mass Spectrometry, Analytical Chemistry, vol.80, issue.8, pp.3050-3057, 2008.
DOI : 10.1021/ac800071n

E. Liotta, R. Gottardo, A. Bertaso, and A. Polettini, Screening for pharmaco-toxicologically relevant compounds in biosamples using high-resolution mass spectrometry: a ???metabolomic??? approach to the discrimination between isomers, Journal of Mass Spectrometry, vol.23, issue.3, pp.261-271, 2010.
DOI : 10.1002/jms.1710

M. Gergov, I. Ojanperä, and E. Vuori, Simultaneous screening for 238 drugs in blood by liquid chromatography???ionspray tandem mass spectrometry with multiple-reaction monitoring, Journal of Chromatography B, vol.795, issue.1, pp.41-53, 2003.
DOI : 10.1016/S1570-0232(03)00498-7

V. Viette, D. Guillarme, R. Mylonas, Y. Mauron, M. Fathi et al., A multi-target screening analysis in human plasma using fast liquid chromatography-hybrid tandem mass spectrometry (Part II), Clinical Biochemistry, vol.44, issue.1, pp.45-53, 2011.
DOI : 10.1016/j.clinbiochem.2010.07.019

H. Maurer, Multi-analyte procedures for screening for and quantification of drugs in blood, plasma, or serum by liquid chromatography-single stage or tandem mass spectrometry (LC-MS or LC-MS/MS) relevant to clinical and forensic toxicology, Clinical Biochemistry, vol.38, issue.4, pp.310-318, 2005.
DOI : 10.1016/j.clinbiochem.2005.01.014

F. Baud, Y. Mouhoub, D. Carmona, B. Mégarbane, and N. Deye, Intoxications médicamenteuses par les antiarythmiques, Sang Thromb Vaiss, vol.19, issue.1, pp.51-55, 2007.

H. Liu, R. Liu, D. Lin, and H. Ho, Rapid screening and confirmation of drugs and toxic compounds in biological specimens using liquid chromatography/ion trap tandem mass spectrometry and automated library search, Rapid Communications in Mass Spectrometry, vol.33, issue.1, pp.75-84, 2010.
DOI : 10.1002/rcm.4365

K. Bonfiglio and M. Olah, The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds, Rapid Communications in Mass Spectrometry, vol.70, issue.12, pp.1175-1185, 1999.
DOI : 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.0.CO;2-0

R. Jansen, G. Lachatre, and P. Marquet, LC-MS/MS systematic toxicological analysis: Comparison of MS/MS spectra obtained with different instruments and settings, Clinical Biochemistry, vol.38, issue.4, pp.362-372, 2005.
DOI : 10.1016/j.clinbiochem.2004.11.003

T. Wilttak, H. Sie, and B. Bod, Ae eeeegee toiolog easueeets eall used ? Clinical chemestry, pp.116-120, 1974.