. Cependant, une gamme de piliers non indexés compatibles avec la nouvelle connexion est commercialisée

B. P. Hansson-b and H. O. , Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year periode, Scand J Plast Reconstr Surg, 1977.

M. D. , B. L. Di, and G. M. , Fixture-abutment connection surface and micro-gap measurements by 3D micro-tomographic technique analysis. Ann DellIstituto Super Sanità, pp.53-61, 2012.

U. C. Steiner-m and I. , Mechanical resistance of screwless morse taper and screw-retained implant-abutment connections, Clin Oral Implants Res, 2013.

C. M. Mécanique, Edition du Renouveau Pédagogique, p.330, 2009.

J. S. Byrne-d and O. , Preloads Generated with Repeated Tightening in Three Types of Screws Used in Dental Implant Assemblies, Journal of Prosthodontics, vol.16, issue.3, pp.164-71, 2006.
DOI : 10.1067/mpr.2002.127604

A. Vianna-c-de, D. J. , and B. Var, Torque stability of different abutment screws submitted to mechanical cycling, Int J Oral Maxillofac Implants, vol.2013, issue.285, pp.209-214

P. Ea and J. Rb, Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants, Int J Oral Maxillofac Implants, vol.7, issue.1, pp.26-33, 1992.

S. M. , A. M. , and M. Fs, Biomechanical effects of platform switching in two different implant systems: a three-dimensional finite element analysis, J Dent Tehran Iran, vol.2013, issue.104, pp.338-50

C. Ar, F. Acl, D. Mattos-m-da, and G. , Mechanical comparison of experimental conical-head abutment screws with conventional flat-head abutment screws for external-hex and internal tri-channel implant connections: an in vitro evaluation of loosening torque, Int J Oral Maxillofac Implants, issue.6, pp.2013-321

S. Ms, Mechanical complications of dental implants, Clin Oral Implants Res, vol.1, pp.156-164, 2000.

H. Pj, L. Wr, and J. T. , Osseointegrated implants for single-tooth replacement: a prospective 5-year multicenter study, Int J Oral Maxillofac Implants, vol.11, issue.4, pp.450-455, 1996.

J. Re, Z. A. , and P. Be, Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years, Clin Oral Implants Res, vol.23, issue.6, pp.2-21, 2012.

T. A. , P. Hp, and T. K. , Abutment screw loosening in single-implant restorations: a systematic review, Int J Oral Maxillofac Implants, vol.23, issue.4, pp.681-90, 2008.

G. Kl, V. Sg, and V. J. , Torque generated by handheld screwdrivers and mechanical torquing devices for osseointegrated implants, Int J Oral Maxillofac Implants, vol.9, issue.2, pp.149-55, 1994.

B. Pp and M. Mchugh, The effect of eliminating implant/abutment rotational misfit on screw joint stability, Int J Prosthodont, vol.9, issue.6, pp.511-520, 1996.

F. M. Delgado-l and M. M. , Analysis of the misfit of dental implant-supported prostheses made with three manufacturing processes, J Prosthet Dent, vol.2014, issue.1112, pp.116-139

N. Rj and S. A. Haney-s, Precision of fit between implant impression coping and implant replica pairs for three implant systems, J Prosthet Dent, vol.2013, issue.1091, pp.37-43

C. J. Van, A. L. , and C. B. , The peri-implant sulcus compared with internal implant and suprastructure components: a microbiological analysis, Clin Implant Dent Relat Res, vol.13, issue.4, pp.286-95, 2011.

N. C. Do, M. Pk, and P. V. , Leakage of saliva through the implant-abutment interface: in vitro evaluation of three different implant connections under unloaded and loaded conditions, Int J Oral Maxillofac Implants, vol.2012, issue.273, pp.551-60

M. Tr, P. Pa, and R. N. , Measurement of masticatory forces and implant loads: a methodologic clinical study, Int J Prosthodont, issue.1, pp.20-27, 2002.

M. Tr, P. Pa, and R. N. , In vivo forces on implants influenced by occlusal scheme and food consistency, Int J Prosthodont, vol.16, issue.5, pp.481-487, 2003.

S. P. Streckbein-rg and W. Jf, Non-linear 3D Evaluation of Different Oral Implant-Abutment Connections, Journal of Dental Research, vol.91, issue.12, pp.91-1184
DOI : 10.1177/0022034512463396

S. Da, N. Ma-de, A. , and P. Mpa, Influence of methodologic aspects on the results of implant-abutment interface microleakage tests: a critical review of in vitro studies, Int J Oral Maxillofac Implants, vol.27, issue.4, pp.793-800, 2012.

L. Verdugo and C. Jaramillo, Microleakage of the prosthetic abutment/implant interface with internal and external connection: In vitro study, Clin Oral Implants Res, 2013.

D. Arc, R. Pho, and R. Lmn, In vitro sealing ability of two materials at five different implant-abutment surfaces, J Periodontol, issue.11, pp.77-1828, 2006.

L. Shen-y-w and H. , A Retrospective Study of Implant?Abutment Connections on Crestal Bone Level, J Dent Res, 2013.

W. D. , N. Mjh, and B. M. , Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogs, Clin Oral Implants Res, vol.19, issue.11, pp.1141-1148, 2008.

S. Fp and H. Neumann-k, Impact of platform switching on marginal peri-implant bone-level changes. A systematic review and metaanalysis, Clin Oral Implants Res, 2014.

M. Dessai, P. Va, and P. R. , Platform switching: A panacea for bone loss??, Journal of Indian Society of Periodontology, vol.17, issue.5, pp.681-684
DOI : 10.4103/0972-124X.119296

C. Cb, M. R. , and N. Py, Mechanical behavior of dental implants in different positions in the rehabilitation of the anterior maxilla, J Prosthet Dent, vol.2014, issue.1114, pp.301-310

P. S. , P. Tv, and S. S. , Comparison of strain generated in bone by " platform-switched " and " non-platform-switched " implants with straight and angulated abutments under vertical and angulated load: a finite element analysis study, Indian J Dent Res Off Publ Indian Soc Dent Res, vol.24, issue.1, pp.8-13, 2013.

K. M. and S. K. Neumann-k, Long-Term Evaluation of ANKYLOS® Dental Implants, Part I: 20-Year Life Table Analysis of a Longitudinal Study of More Than 12,500 Implants, Clin Implant Dent Relat Res, 2013.