P. Hamard, J. Gayraud, and J. Kopel, Treatment of refractory glaucomas by transscleral cyclophotocoagulation using semiconductor diode laser. Analysis of 50 patients followed up over 19 months, J Fr Ophthalmol, vol.20, pp.125-133, 1997.

S. Al-ghamdi, S. Obeidan, K. F. Tomey, and I. Jadaan, Transscleral neodymium:YAG laser cyclophotocoagulation for end-stage glaucoma, refractory glaucoma, and painful blind eyes

D. Roetth and A. Jr, Cryosurgery for the Treatment of Glaucoma*, American Journal of Ophthalmology, vol.61, issue.3, pp.189-204, 1965.
DOI : 10.1016/0002-9394(66)91049-X

M. Maus and L. Katz, Choroidal Detachment, Flat Anterior Chamber, and Hypotony as Complications of Neodymium:YAG Laser Cyclophotocoaguiation, Ophthalmology, vol.97, issue.1, pp.69-72, 1990.
DOI : 10.1016/S0161-6420(90)32640-4

M. Uram, Ophthalmic Laser Microendoscope Ciliary Process Ablation in the Management of Neovascular Glaucoma, Ophthalmology, vol.99, issue.12, pp.1823-1828, 1992.
DOI : 10.1016/S0161-6420(92)31718-X

O. Kosoko, D. Gaasterland, I. Pollack, and C. Enger, Long-term Outcome of Initial Ciliary Ablation with Contact Diode Laser Transscleral Cyclophotocoagulation for Severe Glaucoma, Ophthalmology, vol.103, issue.8, pp.1294-302, 1996.
DOI : 10.1016/S0161-6420(96)30508-3

K. Sabri and S. Vernon, Scleral perforation following trans-scleral cyclodiode, British Journal of Ophthalmology, vol.83, issue.4, pp.502-503, 1999.
DOI : 10.1136/bjo.83.4.501c

S. Vernon, J. Koppens, G. Menon, and A. Negi, Diode laser cycloablation in adult glaucoma: long-term results of a standard protocol and review of current literature, Clinical and Experimental Ophthalmology, vol.83, issue.5, pp.411-420, 2006.
DOI : 10.1111/j.1442-9071.2004.00779.x

F. Aptel, T. Charrel, and X. Palazzi, Histologic Effects of a New Device for High-Intensity Focused Ultrasound Cyclocoagulation, Investigative Opthalmology & Visual Science, vol.51, issue.10, pp.5092-5100, 2010.
DOI : 10.1167/iovs.09-5135

T. Charrel, F. Aptel, and A. Birer, Development of a Miniaturized HIFU Device for Glaucoma Treatment With Conformal Coagulation of the Ciliary Bodies, Ultrasound in Medicine & Biology, vol.37, issue.5, pp.742-54, 2011.
DOI : 10.1016/j.ultrasmedbio.2011.01.017

F. Aptel, T. Charrel, and C. Lafon, Miniaturized High-Intensity Focused Ultrasound Device in Patients with Glaucoma: A Clinical Pilot Study, Investigative Opthalmology & Visual Science, vol.52, issue.12, pp.8747-53, 2011.
DOI : 10.1167/iovs.11-8137

F. Aptel and C. Lafon, Therapeutic applications of ultrasound in ophthalmology, International Journal of Hyperthermia, vol.86, issue.4, pp.405-423, 2012.
DOI : 10.1136/bjo.80.5.389

T. Shaarawy, M. Sherwood, and F. Grehn, Guidelines on Design and Reporting of Glaucoma Surgical Trials, 2009.

F. Aptel, P. Denis, and J. Rouland, Ultrasonic circular cyclo coagulation in patients with primary open-angle glaucoma: preliminary results of a multicenter clinical trial, Acta Ophthalmologica, vol.90
DOI : 10.1111/j.1755-3768.2012.F044.x