.. Facteurs-de-mauvaise-Échogénicité-cavitaire-et-tubaire, 65 7.1. Impact sur l'exploration tubaire, p.65

.. Sélection-de-cas-et-iconographie, 66 8.1, p.66

M. Brandes, J. Van-der-steen, S. Bokdam, C. Hamilton, J. De-bruin et al., When and why do subfertile couples discontinue their fertility care? A longitudinal cohort study in a secondary care subfertility population, Human Reproduction, vol.24, issue.12, pp.3127-3162, 2009.
DOI : 10.1093/humrep/dep340

C. Lim, Z. Hasafa, S. Bhattacharya, and A. Maheshwari, Should a hysterosalpingogram be a first-line investigation to diagnose female tubal subfertility in the modern subfertility workup? Hum Reprod, pp.967-71, 2011.

J. Steinkeler, C. Woodfield, E. Lazarus, and M. Hillstrom, Female Infertility: A Systematic Approach to Radiologic Imaging and Diagnosis, RadioGraphics, vol.29, issue.5, pp.1353-70, 2009.
DOI : 10.1148/rg.295095047

M. Reis, S. Soares, M. Cancado, and A. Camargos, Hysterosalpingo contrast sonography (HyCoSy) with SH U 454 (Echovist) for the assessment of tubal patency, Human Reproduction, vol.13, issue.11, pp.3049-52, 1998.
DOI : 10.1093/humrep/13.11.3049

P. Crosignani and B. Rubin, Optimal use of infertility diagnostic tests and treatments. The ESHRE Capri Workshop Group, Hum Reprod Oxf Engl. mars, vol.15, issue.3, pp.723-755, 2000.

I. Tur-kaspa, M. Gal, M. Hartman, J. Hartman, and A. Hartman, A prospective evaluation of uterine abnormalities by saline infusion sonohysterography in 1,009 women with infertility or abnormal uterine bleeding, Fertility and Sterility, vol.86, issue.6, pp.1731-1736, 2006.
DOI : 10.1016/j.fertnstert.2006.05.044

S. Saravelos, K. Cocksedge, and T. Li, Prevalence and diagnosis of congenital uterine anomalies in women with reproductive failure: a critical appraisal, Human Reproduction Update, vol.14, issue.5, pp.415-444, 2008.
DOI : 10.1093/humupd/dmn018

T. Group and . Workshop, Revised 2003 consensus on diagnostic criteria and long?term health risks related to polycystic ovary syndrome (PCOS), Hum Reprod. 1 janv, vol.19, issue.1, pp.41-48, 2004.

R. Saunders, J. Shwayder, and S. Nakajima, Current methods of tubal patency assessment, Fertility and Sterility, vol.95, issue.7, pp.2171-2180, 2011.
DOI : 10.1016/j.fertnstert.2011.02.054

W. Simpson, L. Beitia, and J. Mester, Hysterosalpingography: A Reemerging Study, RadioGraphics, vol.26, issue.2, pp.419-450, 2006.
DOI : 10.1148/rg.262055109

S. Panchal and C. Nagori, Imaging techniques for assessment of tubal status, Journal of Human Reproductive Sciences, vol.7, issue.1, pp.2-12, 2014.
DOI : 10.4103/0974-1208.130797

C. Lanzani, V. Savasi, F. Leone, M. Ratti, and E. Ferrazzi, Two-dimensional HyCoSy with contrast tuned imaging technology and a second-generation contrast media for the assessment of tubal patency in an infertility program, Fertility and Sterility, vol.92, issue.3, pp.1158-61, 2009.
DOI : 10.1016/j.fertnstert.2008.07.1746

E. Montagne and J. Maillard, Imagerie médicale: Radiologie conventionnelle avec produits de contraste Heures de France, 2005.

A. Maubon, M. Pouquet, P. Piver, N. Mazet, M. Viala-trentini et al., Imagerie de l???infertilit?? f??minine, Journal de Radiologie, vol.89, issue.1, pp.172-83, 2008.
DOI : 10.1016/S0221-0363(08)70391-3

K. Reuter, D. Daly, and S. Cohen, Septate versus bicornuate uteri: errors in imaging diagnosis., Radiology, vol.172, issue.3, pp.749-52, 1989.
DOI : 10.1148/radiology.172.3.2528160

P. Swart, B. Mol, F. Van-der-veen, M. Van-beurden, W. Redekop et al., The accuracy of hysterosalpingography in the diagnosis of tubal pathology: a meta-analysis, Fertility and Sterility, vol.64, issue.3, pp.486-91, 1995.
DOI : 10.1016/S0015-0282(16)57781-4

A. Thurmond, L. Machan, A. Maubon, J. Rouanet, D. Hovsepian et al., A Review of Selective Salpingography and Fallopian Tube Catheterization, RadioGraphics, vol.20, issue.6, pp.1759-68, 2000.
DOI : 10.1148/radiographics.20.6.g00nv211759

D. Noorhasan and M. Heard, Gadolinium radiologic contrast is a useful alternative for hysterosalpingography in patients with iodine allergy, Fertil Steril. déc, vol.84, issue.6, p.1744, 2005.

J. Hartog, C. Lardenoije, J. Severens, J. Land, J. Evers et al., Screening strategies for tubal factor subfertility, Human Reproduction, vol.23, issue.8, pp.1840-1848, 2008.
DOI : 10.1093/humrep/den237

P. Stumpf and C. March, Febrile Morbidity Following Hysterosalpingography: Identification of Risk Factors and Recommendations for Prophylaxis, Fertility and Sterility, vol.33, issue.5, pp.487-92, 1980.
DOI : 10.1016/S0015-0282(16)44712-6

K. Mekaru, C. Yagi, K. Asato, H. Masamoto, K. Sakumoto et al., Hysteroscopic tubal catheterization under laparoscopy for proximal tubal obstruction, Archives of Gynecology and Obstetrics, vol.15, issue.6, pp.1573-1579, 2011.
DOI : 10.1007/s00404-011-2007-6

E. Taylor and V. Gomel, The uterus and fertility, Fertility and Sterility, vol.89, issue.1, pp.1-16, 2008.
DOI : 10.1016/j.fertnstert.2007.09.069

I. Mazzon, A. Favilli, M. Grasso, S. Horvath, V. Bini et al., Pain in diagnostic hysteroscopy: a multivariate analysis after a randomized, controlled trial, Fertility and Sterility, vol.102, issue.5, pp.1398-403, 2014.
DOI : 10.1016/j.fertnstert.2014.07.1249

S. Kayatas, E. Meseci, O. Tosun, S. Arinkan, L. Uygur et al., Experience of hysteroscopy indications and complications in 5,474 cases, Clin Exp Obstet Gynecol, vol.41, issue.4, pp.451-455, 2014.

C. Chapron, F. Pierre, D. Querleu, and J. Dubuisson, Complications de la c??lioscopie en gyn??cologie, Gyn??cologie Obst??trique & Fertilit??, vol.29, issue.9, pp.605-617, 2001.
DOI : 10.1016/S1297-9589(01)00193-X

C. Olivius, B. Friden, G. Borg, and C. Bergh, Why do couples discontinue in vitro fertilization treatment? a cohort study, Fertility and Sterility, vol.81, issue.2, pp.258-61, 2004.
DOI : 10.1016/j.fertnstert.2003.06.029

S. Dessole, M. Farina, G. Capobianco, G. Nardelli, G. Ambrosini et al., Determining the best catheter for sonohysterography, Fertility and Sterility, vol.76, issue.3, pp.605-614, 2001.
DOI : 10.1016/S0015-0282(01)01941-0

G. Monte, G. Capobianco, I. Piva, D. Caserta, S. Dessole et al., Hysterosalpingo contrast sonography (HyCoSy): let???s make the point!, Archives of Gynecology and Obstetrics, vol.17, issue.119, 2014.
DOI : 10.1007/s00404-014-3465-4

S. Seshadri, M. Khalil, A. Osman, A. Clough, K. Jayaprakasan et al., The evolving role of saline infusion sonography (SIS) in infertility, European Journal of Obstetrics & Gynecology and Reproductive Biology, vol.185, pp.66-73, 2015.
DOI : 10.1016/j.ejogrb.2014.11.037

S. Panchal and C. Nagori, Imaging techniques for assessment of tubal status, Journal of Human Reproductive Sciences, vol.7, issue.1, pp.2-12, 2014.
DOI : 10.4103/0974-1208.130797

A. Bij-de-vaate, H. A. Brölmann, J. Van-der-slikke, M. Emanuel, and J. A. Huirne, Gel instillation sonohysterography (GIS) and saline contrast sonohysterography (SCSH): comparison of two diagnostic techniques, Ultrasound in Obstetrics and Gynecology, vol.23, issue.4, pp.486-495, 2010.
DOI : 10.1002/uog.7594

N. Exalto, M. Stassen, and M. Emanuel, Safety aspects and side-effects of ExEm-gel and foam for uterine cavity distension and tubal patency testing, Reproductive BioMedicine Online, vol.29, issue.5, 2014.
DOI : 10.1016/j.rbmo.2014.07.015

M. Emanuel and N. Exalto, Hysterosalpingo-foam sonography (HyFoSy): a new technique to visualize tubal patency, Ultrasound in Obstetrics & Gynecology, vol.37, issue.4, pp.498-507, 2011.
DOI : 10.1002/uog.8912

D. Van-schoubroeck and . Tv, The Use of a New Gel Foam for the Evaluation of Tubal Patency, Gynecologic and Obstetric Investigation, vol.75, issue.3, 2012.
DOI : 10.1159/000345865

S. Maheux-lacroix, A. Boutin, L. Moore, M. Bergeron, E. Bujold et al., Hysterosalpingosonography for diagnosing tubal occlusion in subfertile women: a systematic review with meta-analysis, Human Reproduction, vol.29, issue.5, pp.953-63, 2014.
DOI : 10.1093/humrep/deu024

P. Sladkevicius, K. Ojha, S. Campbell, and G. Nargund, Three-dimensional power Doppler imaging in the assessment of Fallopian tube patency, Ultrasound in Obstetrics and Gynecology, vol.49, issue.7, pp.644-651, 2000.
DOI : 10.1046/j.1469-0705.1999.14030200.x

M. Dauzat, V. Crébassa, A. Pérez-martin, I. Shuster, F. Vivens et al., Interet d???une imagerie de flux non Doppler : le B-Flow, Journal de Radiologie, vol.85, issue.9, p.1236, 2004.
DOI : 10.1016/S0221-0363(04)76764-5

P. Sladkevicius, L. Zannoni, and L. Valentin, B-flow ultrasound facilitates visualization of contrast medium during hysterosalpingo-contrast sonography, Ultrasound in Obstetrics & Gynecology, vol.72, issue.2, pp.221-228, 2014.
DOI : 10.1002/uog.13290

F. Ahmadi, F. Zafarani, H. Haghighi, M. Niknejadi, V. Taqi-dizaj et al., Application of 3D Ultrasonography in Detection of Uterine Abnormalities, Int J Fertil Steril. janv, vol.4, issue.4, pp.144-151, 2011.

E. Caliskan, S. Ozkan, Y. Cakiroglu, H. Sarisoy, A. Corakci et al., Diagnostic accuracy of realtime 3D sonography in the diagnosis of congenital Mullerian anomalies in high-risk patients with respect to the phase of the menstrual cycle, J Clin Ultrasound JCU. avr, vol.38, issue.3, pp.123-130, 2010.

E. Faivre, H. Fernandez, X. Deffieux, A. Gervaise, R. Frydman et al., Accuracy of Three-Dimensional Ultrasonography in Differential Diagnosis of Septate and Bicornuate Uterus Compared with Office Hysteroscopy and Pelvic Magnetic Resonance Imaging, Journal of Minimally Invasive Gynecology, vol.19, issue.1, pp.101-107, 2012.
DOI : 10.1016/j.jmig.2011.08.724

C. Bermejo, M. Ten, P. Cantarero, R. Diaz, D. et al., Three-dimensional ultrasound in the diagnosis of M??llerian duct anomalies and concordance with magnetic resonance imaging, Ultrasound in Obstetrics and Gynecology, vol.18, issue.5, pp.593-601, 2010.
DOI : 10.1002/uog.7551

T. Ghi, P. Casadio, M. Kuleva, A. Perrone, L. Savelli et al., Accuracy of three-dimensional ultrasound in diagnosis and classification of congenital uterine anomalies, Fertility and Sterility, vol.92, issue.2, pp.808-821, 2009.
DOI : 10.1016/j.fertnstert.2008.05.086

S. Seshadri, T. El-toukhy, A. Douiri, K. Jayaprakasan, and Y. Khalaf, Diagnostic accuracy of saline infusion sonography in the evaluation of uterine cavity abnormalities prior to assisted reproductive techniques: a systematic review and meta-analyses, Human Reproduction Update, vol.21, issue.2, pp.262-74, 2015.
DOI : 10.1093/humupd/dmu057

K. Jayaprakasan, L. Polanski, B. Sahu, J. Thornton, and N. Raine-fenning, Surgical intervention versus expectant management for endometrial polyps in subfertile women, Cochrane Database Syst Rev, vol.8, p.9592, 2014.

J. Bosteels, J. Kasius, S. Weyers, F. Broekmans, B. Mol et al., Hysteroscopy for treating subfertility associated with suspected major uterine cavity abnormalities, Cochrane Database Syst Rev, vol.1, p.9461, 2013.

P. Klatsky, N. Tran, A. Caughey, and V. Fujimoto, Fibroids and reproductive outcomes: a systematic literature review from conception to delivery, American Journal of Obstetrics and Gynecology, vol.198, issue.4, pp.357-66, 2008.
DOI : 10.1016/j.ajog.2007.12.039

M. Munro, H. Critchley, and I. Fraser, The FIGO classification of causes of abnormal uterine bleeding in the reproductive years, Fertility and Sterility, vol.95, issue.7, pp.2204-2212, 2011.
DOI : 10.1016/j.fertnstert.2011.03.079

E. Pritts, W. Parker, and D. Olive, Fibroids and infertility: an updated systematic review of the evidence, Fertility and Sterility, vol.91, issue.4, pp.1215-1238, 2009.
DOI : 10.1016/j.fertnstert.2008.01.051

R. Lawson, T. El-toukhy, A. Kassab, A. Taylor, P. Braude et al., Poor response to ovulation induction is a stronger predictor of early menopause than elevated basal FSH: a life table analysis, Human Reproduction, vol.18, issue.3, pp.527-560, 2003.
DOI : 10.1093/humrep/deg101

L. Cohen and R. Valle, Role of vaginal sonography and hysterosonography in the endoscopic treatment of uterine myomas, Fertility and Sterility, vol.73, issue.2, pp.197-204, 2000.
DOI : 10.1016/S0015-0282(99)00508-7

C. Lee, R. Salim, D. Ofili-yebovi, J. Yazbek, A. Davies et al., Reproducibility of the measurement of submucous fibroid protrusion into the uterine cavity using three-dimensional saline contrast sonohysterography, Ultrasound in Obstetrics and Gynecology, vol.20, issue.6, pp.837-878, 2006.
DOI : 10.1002/uog.3832

L. Zhou, X. Zhang, X. Chen, L. Liao, R. Pan et al., Value of three-dimensional hysterosalpingo-contrast sonography with SonoVue in the assessment of tubal patency, Ultrasound in Obstetrics & Gynecology, vol.53, issue.1
DOI : 10.1002/uog.11085

F. Broekmans, D. De-ziegler, C. Howles, A. Gougeon, G. Trew et al., The antral follicle count: practical recommendations for better standardization, Fertility and Sterility, vol.94, issue.3, pp.1044-51, 2010.
DOI : 10.1016/j.fertnstert.2009.04.040

S. Deb, K. Jayaprakasan, B. Campbell, J. Clewes, I. Johnson et al., Intraobserver and interobserver reliability of automated antral follicle counts made using three-dimensional ultrasound and SonoAVC, Ultrasound in Obstetrics and Gynecology, vol.20, issue.4, pp.477-83, 2009.
DOI : 10.1002/uog.6310

B. Ata and T. Tulandi, Ultrasound automated volume calculation in??reproduction and in pregnancy, Fertility and Sterility, vol.95, issue.7, pp.2163-70, 2011.
DOI : 10.1016/j.fertnstert.2011.04.007

S. Deb, M. Batcha, B. Campbell, K. Jayaprakasan, J. Clewes et al., The predictive value of the automated quantification of the number and size of small antral follicles in women undergoing ART, Human Reproduction, vol.24, issue.9, pp.2124-2156, 2009.
DOI : 10.1093/humrep/dep204

K. Jayaprakasan, S. Deb, M. Batcha, J. Hopkisson, I. Johnson et al., The cohort of antral follicles measuring 2???6 mm reflects the quantitative status of ovarian reserve as assessed by serum levels of anti-M??llerian hormone and response to controlled ovarian stimulation, Fertility and Sterility, vol.94, issue.5, pp.1775-81, 2010.
DOI : 10.1016/j.fertnstert.2009.10.022

R. Saunders, S. Nakajima, and J. Myers, Experience improves performance of hysterosalpingocontrast sonography (HyCoSy): a comprehensive and well-tolerated screening modality for the subfertile patient, Clin Exp Obstet Gynecol, vol.40, issue.2, pp.203-212, 2013.

S. Kelly, P. Sladkevicius, S. Campbell, and G. Nargund, Investigation of the infertile couple: a one-stop ultrasound-based approach, Human Reproduction, vol.16, issue.12, pp.2481-2485, 2001.
DOI : 10.1093/humrep/16.12.2481

D. Luciano, C. Exacoustos, and A. Luciano, Contrast Ultrasonography for Tubal Patency, Journal of Minimally Invasive Gynecology, vol.21, issue.6, pp.994-1002, 2014.
DOI : 10.1016/j.jmig.2014.05.017

URL : http://hdl.handle.net/2108/137777

K. Dreyer, R. Out, P. Hompes, and V. Mijatovic, Hysterosalpingo-foam sonography, a??less painful procedure for tubal patency testing during fertility workup compared with (serial) hysterosalpingography: a randomized controlled trial, Fertility and Sterility, vol.102, issue.3, pp.821-826, 2014.
DOI : 10.1016/j.fertnstert.2014.05.042

M. Emanuel, M. Van-vliet, M. Weber, and N. Exalto, First experiences with hysterosalpingo-foam sonography (HyFoSy) for office tubal patency testing, Human Reproduction, vol.27, issue.1, pp.114-121, 2012.
DOI : 10.1093/humrep/der367

J. Hamilton, A. Larson, A. Lower, S. Hasnain, and J. Grudzinskas, Evaluation of the performance of hysterosalpingo contrast sonography in 500 consecutive, unselected, infertile women, Human Reproduction, vol.13, issue.6, pp.1519-1545, 1998.
DOI : 10.1093/humrep/13.6.1519

R. Marci, I. Marcucci, A. Marcucci, N. Pacini, P. Salacone et al., Hysterosalpingocontrast sonography (HyCoSy): evaluation of the pain perception, side effects and complications, BMC Medical Imaging, vol.24, issue.79, p.28, 2013.
DOI : 10.1093/humrep/den485

R. Shojai, A. Ohannessian, J. Maruani, and A. Agostini, Antibioprophylaxie et interventions endo-ut??rines, Journal de Gyn??cologie Obst??trique et Biologie de la Reproduction, vol.41, issue.8, pp.913-934, 2012.
DOI : 10.1016/j.jgyn.2012.09.021

N. Van-eyk and J. Van-schalkwyk, Infectious Diseases Committee Antibiotic prophylaxis in gynaecologic procedures, J Obstet Gynaecol Can JOGC J Obstétrique Gynécologie Can JOGC. avr, vol.34, issue.4, pp.382-91, 2012.

M. Chauhan, P. Lakra, D. Jyotsna, S. Nanda, and V. Malhotra, Pain relief during hysterosalpingography: role of intracervical block, Archives of Gynecology and Obstetrics, vol.26, issue.5, pp.155-164, 2013.
DOI : 10.1007/s00404-012-2515-z

S. Dessole, G. Capobianco, and G. Ambrosini, Timing of Sonohysterography in Menstruating Women, Gynecologic and Obstetric Investigation, vol.50, issue.2, p.144, 2000.
DOI : 10.1159/000010302

C. Lim, Z. Hasafa, S. Bhattacharya, and A. Maheshwari, Should a hysterosalpingogram be a first-line investigation to diagnose female tubal subfertility in the modern subfertility workup? Hum Reprod, pp.967-71, 2011.

S. Coppus, B. Opmeer, S. Logan, F. Veen, . Van-der et al., The predictive value of medical history taking and Chlamydia IgG ELISA antibody testing (CAT) in the selection of subfertile women for diagnostic laparoscopy: a clinical prediction model approach, Human Reproduction, vol.22, issue.5, pp.1353-1361, 2007.
DOI : 10.1093/humrep/del521

A. Malik, S. Jain, M. Rizvi, I. Shukla, and S. Hakim, Chlamydia trachomatis infection in women with secondary infertility, Fertility and Sterility, vol.91, issue.1, pp.91-96, 2009.
DOI : 10.1016/j.fertnstert.2007.05.070

S. Coppus, B. Opmeer, S. Logan, F. Van-der-veen, S. Bhattacharya et al., The predictive value of medical history taking and Chlamydia IgG ELISA antibody testing (CAT) in the selection of subfertile women for diagnostic laparoscopy: a clinical prediction model approach, Human Reproduction, vol.22, issue.5, pp.1353-1361, 2007.
DOI : 10.1093/humrep/del521

F. Luttjeboer, H. Verhoeve, H. Van-dessel, F. Van-der-veen, B. Mol et al., The value of medical history taking as risk indicator for tuboperitoneal pathology: a systematic review, BJOG: An International Journal of Obstetrics & Gynaecology, vol.55, issue.Suppl 4, pp.612-637, 2009.
DOI : 10.1111/j.1471-0528.2008.02070.x

J. Bosteels, V. Herendael, B. Weyers, S. , D. Hooghe et al., The position of diagnostic laparoscopy in current fertility practice, Human Reproduction Update, vol.13, issue.5, pp.477-85, 2007.
DOI : 10.1093/humupd/dmm014

A. Ludwin, K. Pity?ski, I. Ludwin, T. Banas, and A. Knafel, Two- and Three-Dimensional Ultrasonography and Sonohysterography versus Hysteroscopy With Laparoscopy in the Differential Diagnosis of Septate, Bicornuate, and Arcuate Uteri, Journal of Minimally Invasive Gynecology, vol.20, issue.1, pp.90-99, 2013.
DOI : 10.1016/j.jmig.2012.09.011