M. Esposito, J. M. Hirsch, and U. Lekholm, Biological factors contributing to failures of osseointegrated oral implants, (I). Success criteria and epidemiology, European Journal of Oral Sciences, vol.106, issue.1, pp.527-551, 1998.
DOI : 10.1046/j.0909-8836..t01-2-.x

A. , T. Zarb, G. Worthington, and P. , The long-term efficacy of currently used dental implants: a review and proposed criteria of success, The International Journal of Oral & Maxillofacial Implants, vol.1, issue.1, pp.11-25, 1986.

M. Esposito, P. Thomsen, and L. E. Ericson, Histopathologic observations on early oral implant failures, The International Journal of Oral & Maxillofacial Implants. Décembre, vol.14, issue.6, pp.798-810, 1999.
DOI : 10.1111/j.1708-8208.2000.tb00103.x

E. , C. Nelson, R. , F. Assis, A. Nascimento et al., Influence of implant shape, surface morphology, surgical technique and bone quality on the primary stability of dental implants, Journal of the Mechanical Behavior of Biomedical Materials. Décembre 2012, vol.16, pp.169-180

G. Sauro, . Piattelli, D. Adriano, L. Figueiredo, and . Cristina, Histologic evaluation of early human bone response to different implant surfaces, Journal of Periodontology. Octobre, vol.77, issue.10, pp.1736-1743, 2006.

Y. , K. Uoshima, O. Katsumi, and . Kimimitsu, Influence of heat stress to matrix on bone formation, Clinical Oral Implants Research. Août, vol.20, issue.8, pp.782-790, 2009.

T. , P. Et, R. , and W. , Bone classification: clinical-histomorphometric comparison, Clinical Oral Implants Research. Février, vol.10, issue.1, pp.1-7, 1999.

A. Ghada, . Quirynen, . Marc, . Komárek, and . Arnost, Impact of local and systemic factors on the incidence of oral implant failures, up to abutment connection, Journal of Clinical Periodontology. Juillet, vol.34, issue.7, pp.610-617, 2007.

N. Blas, . Muñoz, . Ricardo, . Mesa, and . Francisco, Early implant failure Prognostic capacity of Periotest: retrospective study of a large sample, Clinical Oral Implants Research. Août, vol.17, issue.4, pp.459-464, 2006.

J. Brink, M. , S. J. Et, S. David, and P. , Influence of implant diameter on surrounding bone, Clinical Oral Implants Research, vol.2, issue.5, pp.563-568, 2007.
DOI : 10.1034/j.1600-0501.1997.080208.x

E. Borie, O. , I. Augusta, D. Araujo, and C. P. , The influence of the connection, length and diameter of an implant on bone biomechanics, Acta Odontologica Scandinavica, vol.2013, issue.5, pp.321-329
DOI : 10.1080/10255842.2012.654780

C. , H. , J. , J. J. Et, M. et al., Predictions of bone remodeling around dental implant systems, Journal of Biomechanics. Janvier, vol.41, issue.6, pp.1365-1373, 2008.

M. Valente, D. Lima-da-costa, D. Castro, . Tornavoi, A. Shimano et al., Analysis of the influence of implant shape on primary stability using the correlation of multiple methods, Clinical Oral Investigations, vol.43, issue.8, 2015.
DOI : 10.1007/s00784-015-1417-4

C. Xu, W. Zhong, . Liu, and . Nizhou, The Effect of Implant Shape and Screw Pitch on Microdamage in Mandibular Bone, Clinical Implant Dentistry and Related Research, vol.16, issue.Pt 2, pp.365-372, 2015.
DOI : 10.1111/cid.12100

L. , J. , Y. Jin-hyuk, and H. Ji-youn, Early bone healing onto implant surface treated by fibronectin/oxysterol for cell adhesion/osteogenic differentiation: in vivo experimental study in dogs, Journal of Periodontal & Implant Science. 2014, vol.44, issue.5, p.242

C. , L. Khocht, S. Ahmed, and J. B. , Effect of implant design on initial stability of tapered implants. The Journal of Oral Implantology, pp.130-135, 2009.

M. , A. Calvo-guirado, J. Luís, . Lazi?, and . Zoran, Evaluation of primary stability of self-tapping and non-self-tapping dental implants. A 12-week clinical study. Clinical Implant Dentistry and Related Research, pp.341-349, 2013.

A. Goran, . Davila, . Slavko, . Udiljak, and . Toma, Determination of spatial distribution of increase in bone temperature during drilling by infrared thermography: preliminary report. Archives of Orthopaedic and Trauma Surgery, pp.703-709, 2009.

Y. Sinem, J. Ryo, and C. Marin, The effect of drilling speed on early bone healing to oral implants. Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, Novembre 2013, vol.116, issue.5, pp.550-555

A. Goran, . Davila, . Slavko, . Mihoci, and . Kristijan, Thermal osteonecrosis and bone drilling parameters revisited. Archives of Orthopaedic and Trauma Surgery, pp.71-77, 2008.

S. , B. Cem, . Dergin, . Guhan, . Gursoy et al., Effects of irrigation temperature on heat control in vitro at different drilling depths, Clinical Oral Implants Research. Mars, vol.20, issue.3, pp.294-298, 2009.

. Harder, . Sönke, . Egert, W. Christopher, and H. J. , Influence of the drill material and method of cooling on the development of intrabony temperature during preparation of the site of an implant, British Journal of Oral and Maxillofacial Surgery, vol.51, issue.1, pp.74-78
DOI : 10.1016/j.bjoms.2012.02.003

S. , G. D. Unger, . Ewald, . Donner, and . René, Thermal effects of a combined irrigation method during implant site drilling. A standardized in vitro study using a bovine rib model, Clinical Oral Implants Research. Juin 2014, vol.25, issue.6, pp.665-674

A. Scarano, . Piattelli, . Adriano, . Assenza, and . Bartolomeo, Infrared thermographic evaluation of temperature modifications induced during implant site preparation with cylindrical versus conical drills. Clinical Implant Dentistry and Related Research, pp.319-323, 2011.

B. Mendes, G. Cury, L. E. Padovan, R. Marques, and P. Domingos, Influence of implant drill materials on wear, deformation, and roughness after repeated drilling and sterilization. Implant Dentistry, pp.188-194, 2014.

A. Scarano, F. Carinci, and A. Quaranta, Effects of bur wear during implant site preparation: an in vitro study, International Journal of Immunopathology and Pharmacology. Mars, vol.20, issue.1, pp.23-26, 2007.

G. , S. Alexandre, . Bettach, . Raphaél, . Taschieri et al., Temperature Changes in Cortical Bone after Implant Site Preparation Using a Single Bur versus Multiple Drilling Steps: An In Vitro Investigation. Clinical Implant Dentistry and Related Research, Août 2015, vol.17, issue.4, pp.700-707

. Bayarchimeg, . Dorjpalam, . Namgoong, K. Hee, and B. Kook, Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test, Journal of Periodontal & Implant Science, vol.43, issue.1, pp.30-36
DOI : 10.5051/jpis.2013.43.1.30

T. , P. Todisco, . Marzio, . Consolo, and . Ugo, High versus low implant insertion torque: a histologic, histomorphometric, and biomechanical study in the sheep mandible, The International Journal of Oral & Maxillofacial Implants. Août, vol.26, issue.4, pp.837-849, 2011.

K. , P. G. Arnal, M. Hélène, . Tourbah, and I. Bahige, Clinical outcome of dental implants placed with high insertion torques (up to 176 Ncm) Clinical Implant Dentistry and Related Research, pp.227-233, 2013.

C. Makary, R. Alberto, . Mokbel, and . Nadim, Peak Insertion Torque Correlated to Histologically and Clinically Evaluated Bone Density, Implant Dentistry, vol.20, issue.3, pp.182-191, 2011.
DOI : 10.1097/ID.0b013e31821662b9

M. , A. Ferhat, . Sumer, Y. Mahmut, and . Murat, Effect of surgical drill guide on heat generated from implant drilling, Journal of Oral and Maxillofacial Surgery: Official Journal of the American Association of Oral and Maxillofacial Surgeons. Décembre, vol.67, pp.12-2663, 2009.

D. Jan, . Van-de, . Velde, . Tommie, . Komiyama et al., Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature, Clinical Implant Dentistry and Related Research, vol.14, issue.3, pp.321-335, 2012.

M. Tsoukaki, K. , C. D. Sakellari, and . Dimitra, Clinical, radiographic, microbiological, and immunological outcomes of flapped vs. flapless dental implants: a prospective randomized controlled clinical trial, Clinical Oral Implants Research, vol.107, issue.Suppl. 1, pp.969-976
DOI : 10.1111/j.1600-0501.2012.02503.x

J. Seung-mi, Y. Je-hyeon, . Fang, and . Yiqin, The effect of guided flapless implant procedure on heat generation from implant drilling, Journal of Cranio-Maxillofacial Surgery. Septembre 2014, vol.42, issue.6, pp.725-729

M. Marquezan, A. Osório, . Sant-'anna, and . Eduardo, Does bone mineral density influence the primary stability of dental implants? A systematic review, Clinical Oral Implants Research, vol.67, issue.7, pp.767-774
DOI : 10.1111/j.1600-0501.2011.02228.x

R. , R. Faria, D. Oliveira, R. C. Gomes, D. et al., Bone tissue microarchitectural characteristics at dental implant sites part 2: correlation with bone classification and primary stability, Clinical Oral Implants Research. Février 2014, vol.25, issue.2, pp.47-53

M. , A. Suarez, G. Fernando, and C. Andrés, Effect of location on primary stability and healing of dental implants. Implant Dentistry, pp.69-73, 2014.

I. Kei, . Ayukawa, . Yasunori, . Tsukiyama, and . Yoshihiro, Relationship between the bone density estimated by cone-beam computed tomography and the primary stability of dental implants, Clinical Oral Implants Research. Juillet 2012, vol.23, issue.7, pp.832-836

K. , M. Palarie, . Victor, . Nacu, and . Viorel, Effect of Intraoperative Bone Quality Testing on Bone Healing and Osseointegration of Dental Implants, The International Journal of Oral & Maxillofacial Implants. 2013, vol.28, issue.5, pp.1254-1260

. Banayan, E. Samuel, R. Bruno, and . Patrick, Int??r??ts du proc??d?? T.B.S. dans la d??termination de la qualit?? de l???os en odontologie, Actualit??s Odonto-Stomatologiques, issue.252
DOI : 10.1051/aos/2010404

M. , F. , M. Fini, . Gianluca, and . Giavaresi, Peri-implant osteogenesis in health and osteoporosis, Micron, vol.36, pp.7-8, 1993.

S. , G. A. Pisano, T. Messina, and M. , In vivo » evaluation of the vascular pattern in oral peri-implant tissues, Archives of Oral Biology. Février, vol.56, issue.2, pp.148-152, 2011.

T. Tonino, N. , A. B. Piattelli, and . Adriano, The relationship between interimplant distances and vascularization of the interimplant bone, Clinical Oral Implants Research. Août, vol.21, issue.8, pp.822-829, 2010.

E. Attar, M. S. Mourad, H. Hazem, . Mahmoud, and . Aly, Early Osteotomy With Delayed Implant Placement: A Step Further for Immediate Loading, Implant Dentistry, vol.15, issue.1, pp.18-23, 2006.
DOI : 10.1097/01.id.0000202427.15792.17

J. Bansal, . Kedige, . Suresh, . Bansal, and . Abhishek, A Relaxed Implant Bed: Implants Placed After Two Weeks of Osteotomy With Immediate Loading: A One Year Clinical Trial, Journal of Oral Implantology, vol.38, issue.2, pp.155-164, 2012.
DOI : 10.1563/AAID-JOI-D-10-00036