B. 1. Shillingburg, H. Hobo, S. Whitsett, and L. , Bases fondamentales en prothèse fixée. Éditions CdP, 1998.

V. Bennani and C. Baudoin, Esthétique et profil d'émergence en implantologie

C. Bastiat, Le profil d'émergence en prothèse fixée implanto-portée. Thèse Bordeaux 2-Victor Segalen; 2009. 13. Kancyper SG, Koka S. The influence of intracrevicular crown margins on gingival health : Preliminary findings, J Prosthet Dent, vol.85, issue.5, pp.461-466, 2001.

A. Padbury, . Jr, R. Eber, and H. Wang, Interactions between the gingiva and the margin of restorations, Journal of Clinical Periodontology, vol.29, issue.5, pp.379-85, 2003.
DOI : 10.1034/j.1600-051X.2003.01277.x

M. Perel, Axial crown contours, The Journal of Prosthetic Dentistry, vol.25, issue.6, pp.642-651, 1971.
DOI : 10.1016/0022-3913(71)90127-2

R. Kohal, J. Strub, and T. Gerds, Effect of different crown contours on periodontal health in dogs. Clinical results, Journal of Dentistry, vol.31, issue.6, pp.407-420, 2003.
DOI : 10.1016/S0300-5712(03)00070-8

J. Du, H. Li, J. Wu, H. Lee, and C. Wang, Emergence Angles of the Cementoenamel Junction in Natural Maxillary Anterior Teeth, Journal of Esthetic and Restorative Dentistry, vol.63, issue.6, pp.362-371, 2011.
DOI : 10.1111/j.1708-8240.2011.00471.x

A. Stafin-zerbib, Incidences parodontales des accès aux limites en prothèse fixée: revue de littérature 2ème partie, Strat Prothétique, vol.8, issue.3, pp.183-95, 2008.

J. Feng, The Effect of Gingival Retraction Procedures on Periodontal Indices and Crevicular Fluid Cytokine Levels: A Pilot Study, Journal of Prosthodontics, vol.16, issue.2, pp.108-120, 2006.
DOI : 10.1067/mpr.2001.115276

H. Loë and J. Silness, Tissue reactions to string packs used in fixed restorations, The Journal of Prosthetic Dentistry, vol.13, issue.2
DOI : 10.1016/0022-3913(63)90177-X

J. Geoffrion, B. Brendel, and J. Blanchard, L'accès sous-gingival en prothèse fixée : conséquences tissulaires, guidage de la cicatrisation, Cah Prothèse, issue.58, pp.31-50, 1987.

J. Ruel, P. Schuessler, K. Malament, and D. Mori, Effect of retraction procedures on the periodontium in humans, The Journal of Prosthetic Dentistry, vol.44, issue.5, pp.508-523, 1980.
DOI : 10.1016/0022-3913(80)90069-4

A. Hamad, K. Azar, W. Alwaeli, H. Said, and K. , A clinical study on the effects of cordless and conventional retraction techniques on the gingival and periodontal health, Journal of Clinical Periodontology, vol.24, issue.12, pp.1053-1061, 2008.
DOI : 10.1111/j.1600-051X.2008.01335.x

E. Sitbon, D. Dot, and M. Denis, Mise en évidence des limites de préparation lors des empreintes en prothèse fixée : revue de synthèse, Entret Odontol-Stomatol, pp.41-46, 2010.

B. Laufer, H. Baharav, and H. Cardash, The linear accuracy of impressions and stone dies as affected by the thickness of the impression margin, Int J Prosthodont, vol.7, issue.3, pp.247-52, 1994.

H. Baharav, I. Kupershmidt, B. Laufer, and H. Cardash, The effect of sulcular width on the linear accuracy of impression materials in the presence of an undercut

M. Fradeani and G. Barducci, Réhabilitation esthétique en prothèse fixée: une approche de l'intégration esthétique, biologique et fonctionnelle. Traitement prothétique, Ed:Quintessence International, 2009.

S. Armand and H. Couret, Profil d'émergence en prothèse fixée : intérêts de la double empreinte, Cah Prothèse, issue.125, pp.17-25, 2004.

M. Bassiouny and L. Yearwood, Establishing the gingival emergence profile of restorations by using a resilient gingival replica, The Journal of Prosthetic Dentistry, vol.76, issue.4, pp.386-395, 1996.
DOI : 10.1016/S0022-3913(96)90543-0

S. Ahmad, C. Tredwin, M. Nesbit, and D. Moles, Effect of immersion disinfection with Perform-ID on alginate, an alginate alternative, an addition-cured silicone and resultant type III gypsum casts):E1; discussion 36?37. 62. Ender A, Mehl A. In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions, Br Dent J. Quintessence Int, vol.202, issue.461, pp.9-17, 2015.

A. Keating, J. Knox, R. Bibb, A. Zhurov, K. Vig et al., A comparison of plaster, digital and reconstructed study model accuracy The accuracy and reliability of measurements made on computer-based digital models, J Orthod. Angle Orthod, vol.35, issue.743, pp.191-201298, 2004.