R. Brown, J. Broderick, and J. , Unruptured intracranial aneurysms: epidemiology, natural history, management options, and familial screening, The Lancet Neurology, vol.13, issue.4, pp.393-404, 2014.
DOI : 10.1016/S1474-4422(14)70015-8

M. Vernooij, M. Ikram, and H. Tanghe, Incidental Findings on Brain MRI in the General Population, New England Journal of Medicine, vol.357, issue.18, pp.1821-1828, 2007.
DOI : 10.1056/NEJMoa070972

N. Etminan, B. Buchholz, and R. Dreier, Cerebral Aneurysms: Formation, Progression, and Developmental Chronology, Translational Stroke Research, vol.153, issue.2, pp.167-173, 2014.
DOI : 10.1007/s12975-013-0294-x

S. Juvela, M. Hillbom, H. Numminen, and P. Koskinen, Cigarette smoking and alcohol consumption as risk factors for aneurysmal subarachnoid hemorrhage. Stroke; a journal of cerebral circulation, pp.639-646, 1993.

I. Shiue, H. Arima, G. Hankey, C. Anderson, and A. Group, Modifiable lifestyle behaviours account for most cases of subarachnoid haemorrhage: A population-based case???control study in Australasia, Journal of the Neurological Sciences, vol.313, issue.1-2, pp.92-94, 2012.
DOI : 10.1016/j.jns.2011.09.017

W. Longstreth, J. Nelson, L. Koepsell, T. Van-belle, and G. , Cigarette smoking, alcohol use, and subarachnoid hemorrhage. Stroke; a journal of cerebral circulation, pp.1242-1249, 1992.

P. Knekt, A. Reunanen, and K. Aho, Risk factors for subarachnoid hemorrhage in a longitudinal population study, Journal of Clinical Epidemiology, vol.44, issue.9, pp.933-939, 1991.
DOI : 10.1016/0895-4356(91)90056-F

S. Johnston, J. Colford, J. Gress, and D. , Oral contraceptives and the risk of subarachnoid hemorrhage: A meta-analysis, Neurology, vol.51, issue.2, pp.411-418, 1998.
DOI : 10.1212/WNL.51.2.411

F. Linn, G. Rinkel, A. Algra, and J. Van-gijn, Incidence of subarachnoid hemorrhage: role of region, year, and rate of computed tomography: a meta-analysis. Stroke; a journal of cerebral circulation, pp.625-629, 1996.

W. Mckissock, A. Richardson, W. L. Middle-cerebral, . Aneurysms, . Results et al., MIDDLE-CEREBRAL ANEURYSMS FURTHER RESULTS IN THE CONTROLLED TRIAL OF CONSERVATIVE AND SURGICAL TREATMENT OF RUPTURED INTRACRANIAL ANEURYSMS, The Lancet, vol.280, issue.7253, pp.417-421
DOI : 10.1016/S0140-6736(62)90280-5

W. Mckissock, A. Richardson, and L. Walsh, POSTERIOR-COMMUNICATING " ANEURYSMS. The Lancet, pp.1203-1206

W. Mckissock, A. Richardson, and L. Walsh, ANTERIOR COMMUNICATING ANEURYSMS A TRIAL OF CONSERVATIVE AND SURGICAL TREATMENT, The Lancet, vol.285, issue.7391, pp.874-876, 1965.
DOI : 10.1016/S0140-6736(65)92616-4

I. Van-der-schaaf, A. Algra, and M. Wermer, Endovascular coiling versus neurosurgical clipping for patients with aneurysmal subarachnoid haemorrhage. The Cochrane database of systematic reviews, p.3085, 2005.

G. Guglielmi, F. Vinuela, I. Sepetka, and V. Macellari, Electrothrombosis of saccular aneurysms via endovascular approach, Journal of Neurosurgery, vol.75, issue.1, pp.1-7, 1991.
DOI : 10.3171/jns.1991.75.1.0001

A. Molyneux, R. Kerr, and I. Stratton, International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial, The Lancet, vol.360, issue.9342, pp.1267-1274, 2002.
DOI : 10.1016/S0140-6736(02)11314-6

A. Qureshi, A. Luft, M. Sharma, L. Guterman, and L. Hopkins, Prevention and Treatment of Thromboembolic and Ischemic Complications Associated with Endovascular Procedures: Part I???Pathophysiological and Pharmacological Features, Neurosurgery, vol.46, issue.6, pp.1344-1359, 2000.
DOI : 10.1097/00006123-200006000-00012

A. Qureshi, A. Luft, M. Sharma, L. Guterman, and L. Hopkins, Prevention and Treatment of Thromboembolic and Ischemic Complications Associated with Endovascular Procedures: Part II???Clinical Aspects and Recommendations, Neurosurgery, vol.46, issue.6, pp.1360-1375, 2000.
DOI : 10.1097/00006123-200006000-00014

H. Versteeg, J. Heemskerk, M. Levi, and P. Reitsma, New Fundamentals in Hemostasis, Physiological Reviews, vol.93, issue.1, pp.327-358, 2013.
DOI : 10.1152/physrev.00016.2011

S. Bracard, C. Barbier, A. Derelle, and R. Anxionnat, Endovascular treatment of aneurisms: Pre, intra and post operative management, European Journal of Radiology, vol.82, issue.10, pp.1633-1637, 2013.
DOI : 10.1016/j.ejrad.2013.02.012

R. Vanninen, T. Koivisto, T. Saari, J. Hernesniemi, and M. Vapalahti, Ruptured Intracranial Aneurysms: Acute Endovascular Treatment with Electrolytically Detachable Coils???A Prospective Randomized Study, Radiology, vol.211, issue.2, pp.325-336, 1999.
DOI : 10.1148/radiology.211.2.r99ap06325

E. Brilstra, G. Rinkel, Y. Van-der-graaf, W. Van-rooij, and A. Algra, Treatment of intracranial aneurysms by embolization with coils: a systematic review. Stroke; a journal of cerebral circulation, pp.470-476, 1999.

M. Alexander, G. Duckwiler, Y. Gobin, and F. Vinuela, Management of Intraprocedural Arterial Thrombus in Cerebral Aneurysm Embolization with Abciximab: Technical Case Report, Neurosurgery, vol.50, issue.4, pp.899-901, 2002.
DOI : 10.1097/00006123-200204000-00045

H. Henkes, S. Fischer, and W. Weber, Endovascular Coil Occlusion of 1811 Intracranial Aneurysms: Early Angiographic and Clinical Results, Neurosurgery, vol.54, issue.2, pp.268-280, 2004.
DOI : 10.1227/01.NEU.0000103221.16671.F0

H. Park, M. Horowitz, and C. Jungreis, Periprocedural morbidity and mortality associated with endovascular treatment of intracranial aneurysms, AJNR. American journal of neuroradiology, vol.26, issue.3, pp.506-514, 2005.

S. Gallas, A. Pasco, and J. Cottier, A multicenter study of 705 ruptured intracranial aneurysms treated with Guglielmi detachable coils, AJNR. American journal of neuroradiology, vol.26, issue.7, pp.1723-1731, 2005.

L. Pierot, A. Bonafe, S. Bracard, and X. Leclerc, French Matrix Registry I. Endovascular treatment of intracranial aneurysms with matrix detachable coils: immediate posttreatment results from a prospective multicenter registry, AJNR. American journal of neuroradiology, vol.27, issue.8, pp.1693-1699, 2006.

L. Pierot, C. Cognard, R. Anxionnat, F. Ricolfi, and C. Investigators, Ruptured Intracranial Aneurysms: Factors Affecting the Rate and Outcome of Endovascular Treatment Complications in a Series of 782 Patients (CLARITY Study), Radiology, vol.256, issue.3, pp.916-923, 2010.
DOI : 10.1148/radiol.10092209

M. Cronqvist, R. Wirestam, and B. Ramgren, Diffusion and perfusion MRI in patients with ruptured and unruptured intracranial aneurysms treated by endovascular coiling: complications, procedural results, MR findings and clinical outcome, Neuroradiology, vol.100, issue.2, pp.855-873, 2005.
DOI : 10.1007/s00234-005-1408-2

T. Altay, H. Kang, and H. Woo, Thromboembolic events associated with endovascular treatment of cerebral aneurysms, Journal of NeuroInterventional Surgery, vol.3, issue.2, pp.147-150, 2011.
DOI : 10.1136/jnis.2010.003616

Y. Fujii, S. Takeuchi, A. Harada, H. Abe, O. Sasaki et al., Hemostatic Activation in Spontaneous Intracerebral Hemorrhage, Stroke, vol.32, issue.4, pp.883-890, 2001.
DOI : 10.1161/01.STR.32.4.883

L. Tumialan, Y. Zhang, C. Cawley, J. Dion, F. Tong et al., Intracranial hemorrhage associated with stent-assisted coil embolization of cerebral aneurysms: a cautionary report, Journal of Neurosurgery, vol.108, issue.6, pp.1122-1129, 2008.
DOI : 10.3171/JNS/2008/108/6/1122

H. Cloft and D. Kallmes, Cerebral aneurysm perforations complicating therapy with Guglielmi detachable coils: a meta-analysis, AJNR. American journal of neuroradiology, vol.23, issue.10, pp.1706-1709, 2002.

G. Bernardini, S. Mayer, S. Kossoff, L. Hacein-bey, R. Solomon et al., Anticoagulation and induced hypertension after endovascular treatment for ruptured intracranial aneurysms, Critical Care Medicine, vol.29, issue.3, pp.641-644, 2001.
DOI : 10.1097/00003246-200103000-00033

T. Oxley, R. Dowling, P. Mitchell, S. Davis, and Y. B. , Antiplatelet Resistance and Thromboembolic Complications in Neurointerventional Procedures, Frontiers in Neurology, vol.2, p.83, 2011.
DOI : 10.3389/fneur.2011.00083

A. Society, I. Therapeutic, and N. , General considerations for endovascular surgical neuroradiologic procedures, AJNR. American journal of neuroradiology, vol.22, issue.8, pp.1-3, 2001.

B. Boutiere, Temps de céphaline plus activateur. EMC -Biologie médicale, pp.90-110, 2003.

S. Bates and J. Weitz, Coagulation Assays, Circulation, vol.112, issue.4, pp.53-60, 2005.
DOI : 10.1161/CIRCULATIONAHA.104.478222

B. Boutiere, Mesure de l'héparinémie par activité anti-Xa. EMC -Biologie médicale, 2003.

D. Garcia, T. Baglin, J. Weitz, and M. Samama, Parenteral Anticoagulants, Chest, vol.141, issue.2, pp.24-43, 2012.
DOI : 10.1378/chest.11-2291

URL : http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3278070

P. Hattersley, Activated Coagulation Time of Whole Blood, JAMA: The Journal of the American Medical Association, vol.196, issue.5, pp.436-440, 1966.
DOI : 10.1001/jama.1966.03100180108036

P. Meyers, H. Schumacher, and R. Higashida, Reporting standards for endovascular repair of saccular intracranial cerebral aneurysms, AJNR. American journal of neuroradiology, vol.31, issue.1, pp.12-24, 2010.

G. Despotis, A. Summerfield, and J. Joist, Comparison of activated coagulation time and whole blood heparin measurements with laboratory plasma anti-Xa heparin concentration in patients having cardiac operations. The Journal of thoracic and cardiovascular surgery, pp.1076-1082, 1994.

D. Giavarina, M. Carta, A. Fabbri, J. Manfredi, E. Gasparotto et al., Monitoring high-dose heparin levels by ACT and HMT during extracorporeal circulation: diagnostic accuracy of three compact monitors, Perfusion, vol.17, issue.1, pp.23-26, 2002.
DOI : 10.1191/0267659102pf530oa

J. Koerber, M. Smythe, R. Begle, J. Mattson, B. Kershaw et al., Correlation of Activated Clotting Time and Activated Partial Thromboplastin Time to Plasma Heparin Concentration, Pharmacotherapy, vol.102, issue.1, pp.922-931, 1999.
DOI : 10.1002/ccd.1810260404

M. Ganter, A. Monn, and R. Tavakoli, Monitoring activated clotting time for combined heparin and aprotinin application: in vivo evaluation of a new aprotinin-insensitive test using Sonoclot???, European Journal of Cardio-Thoracic Surgery, vol.30, issue.2, pp.278-284, 2006.
DOI : 10.1016/j.ejcts.2006.05.016

B. Tremey, B. Szekely, and S. Schlumberger, Anticoagulation monitoring during vascular surgery: accuracy of the Hemochron(R) low range activated clotting time (ACT-LR), British Journal of Anaesthesia, vol.97, issue.4, pp.453-459, 2006.
DOI : 10.1093/bja/ael194

T. Ambrose, C. Parvin, E. Mendeloff, and L. Luchtman-jones, Evaluation of the TAS analyzer and the lowrange heparin management test in patients undergoing extracorporeal membrane oxygenation, Clinical chemistry, vol.47, issue.5, pp.858-866, 2001.

L. Jaques and A. Ricker, The relationship between heparin dosage and clotting time, Blood, vol.3, issue.10, pp.1197-1212, 1948.

S. Dalbert, M. Ganter, L. Furrer, R. Klaghofer, A. Zollinger et al., Effects of heparin, haemodilution and aprotinin on kaolin-based activated clotting time: in vitro comparison of two different point of care devices, Acta Anaesthesiologica Scandinavica, vol.33, issue.4, pp.461-468, 2006.
DOI : 10.1097/00000542-199510000-00006

L. Girardi, K. Sudi, and W. Muntean, Effect of Heparin, Platelets, Activated Platelets, Platelet Fragments, and Hematocrit on Activated Clotting Time, Artificial Organs, vol.193, issue.1, pp.507-513, 2000.
DOI : 10.1016/0003-4975(96)00386-4

T. Ammar, C. Fisher, K. Sarier, and B. Coller, The effects of thrombocytopenia on the activated coagulation time. Anesthesia and analgesia, pp.1185-1188, 1996.

C. Takemoto, M. Streiff, and K. Shermock, Activated Partial Thromboplastin Time and Anti-Xa Measurements in Heparin Monitoring: Biochemical Basis for Discordance, American Journal of Clinical Pathology, vol.139, issue.4, pp.450-456, 2013.
DOI : 10.1309/AJCPS6OW6DYNOGNH

A. Cuker, B. Ptashkin, and B. Konkle, Interlaboratory agreement in the monitoring of unfractionated heparin using the anti-factor??Xa-correlated activated partial thromboplastin time, Journal of Thrombosis and Haemostasis, vol.79, issue.1, pp.80-86, 2009.
DOI : 10.1111/j.1538-7836.2008.03224.x

O. Thomas, E. Lybeck, K. Strandberg, N. Tynngard, and U. Schott, Monitoring Low Molecular Weight Heparins at Therapeutic Levels: Dose-Responses of, and Correlations and Differences between aPTT, Anti-Factor Xa and Thrombin Generation Assays, PLOS ONE, vol.126, issue.1, p.116835, 2015.
DOI : 10.1371/journal.pone.0116835.s003

S. Kuhle, P. Eulmesekian, and B. Kavanagh, Lack of correlation between heparin dose and standard clinical monitoring tests in treatment with unfractionated heparin in critically III children, Haematologica, vol.92, issue.4, pp.554-557, 2007.
DOI : 10.3324/haematol.10696

A. Schroeder, L. Knudsen, S. Husted, L. Knudsen, and J. Ingerslev, Bedside coagulometry during intravenous heparin therapy after coronary angioplasty, Journal of Thrombosis and Thrombolysis, vol.12, issue.2, pp.157-163, 2001.
DOI : 10.1023/A:1012923505198

A. Douglas, J. Jefferis, R. Sharma, R. Parker, A. Handa et al., Evaluation of Point-of-care Activated Partial Thromboplastin Time Testing by Comparison to Laboratory-based Assay for Control of Intravenous Heparin, Angiology, vol.60, issue.3, pp.358-361, 2009.
DOI : 10.1177/0003319709332958

B. Ro and J. Reul, Guidelines for Peri-and Intra-Procedural Anticoagulation and Antiaggregation/Anticoagulation-Protocols/guidelines-for-peri-and-intra-procedural-anticoagulationand-antiaggregation .html, 2007.

R. Becker, S. Ball, and P. Eisenberg, A randomized, multicenter trial of weight-adjusted intravenous heparin dose titration and point-of-care coagulation monitoring in hospitalized patients with active thromboembolic disease, American Heart Journal, vol.137, issue.1, pp.59-71, 1999.
DOI : 10.1016/S0002-8703(99)70460-6

R. Raschke, J. Hirsh, and J. Guidry, Suboptimal monitoring and dosing of unfractionated heparin in comparative studies with low-molecular-weight heparin. Annals of internal medicine, pp.720-723, 2003.

J. Yau, A. Stafford, P. Liao, J. Fredenburgh, R. Roberts et al., Mechanism of catheter thrombosis: comparison of the antithrombotic activities of fondaparinux, enoxaparin, and heparin in vitro and in vivo, Blood, vol.118, issue.25, pp.6667-6674, 2011.
DOI : 10.1182/blood-2011-07-364141

I. Jaffer, J. Fredenburgh, J. Hirsh, and J. Weitz, Medical device-induced thrombosis: what causes it and how can we prevent it? Journal of thrombosis and haemostasis, JTH, vol.13, issue.1, pp.72-81, 2015.

C. Walker and D. Royston, Thrombin generation and its inhibition: a review of the scientific basis and mechanism of action of anticoagulant therapies, British Journal of Anaesthesia, vol.88, issue.6, pp.848-863, 2002.
DOI : 10.1093/bja/88.6.848

J. Hirsh, W. Van-aken, A. Gallus, C. Dollery, and J. Cade, Heparin kinetics in venous thrombosis and pulmonary embolism, Circulation, vol.53, issue.4, p.598, 1975.
DOI : 10.1161/01.CIR.53.4.691

T. Bjornsson, K. Wolfram, and B. Kitchell, Heparin kinetics determined by three assay methods, Clinical Pharmacology and Therapeutics, vol.31, issue.1, pp.104-113, 1982.
DOI : 10.1038/clpt.1982.16

R. Cipolle, R. Seifert, B. Neilan, D. Zaske, and E. Haus, Heparin kinetics: Variables related to disposition and dosage, Clinical Pharmacology and Therapeutics, vol.29, issue.3, pp.387-393, 1981.
DOI : 10.1038/clpt.1981.53

T. Bjornsson and G. Levy, Pharmacokinetics of heparin. I. Studies of dose dependence in rats. The Journal of pharmacology and experimental therapeutics, pp.237-242, 1979.

T. Bjornsson and G. Levy, Pharmacokinetics of heparin. II. Studies of time dependence in rats. The Journal of pharmacology and experimental therapeutics, pp.243-246, 1979.

C. De-swart, B. Nijmeyer, J. Roelofs, and J. Sixma, Kinetics of intravenously administered heparin in normal humans, Blood, vol.60, issue.6, pp.1251-1258, 1982.

P. Olsson, H. Lagergren, and S. Ek, The Elimination from Plasma of Intravenous Heparin An Experimental Study on Dogs and Humans, Acta Medica Scandinavica, vol.3, issue.Suppl. 15, pp.619-630, 1963.
DOI : 10.1111/j.0954-6820.1963.tb17446.x

M. Wachsman, C. Mielke, J. Hayes, J. Baker, and D. , The use of time step simulations and difference equations (TSSADEQ) in modeling heparin pharmacokinetics, J Clin Pharmacol, vol.40, issue.10, pp.1121-1128, 2000.

A. Jacob, R. Steingart, and M. Schweger, Heparin elimination following continuous infusion during intra-aortic balloon counterpulsation, Catheterization and Cardiovascular Diagnosis, vol.29, issue.4, pp.389-392, 1985.
DOI : 10.1002/ccd.1810110406

Y. Cai, L. Spelle, and H. Wang, Endovascular Treatment of Intracranial Aneurysms in the Elderly: Single-Center Experience in 63 Consecutive Patients, Neurosurgery, vol.57, issue.6, pp.1096-1102, 2005.
DOI : 10.1227/01.NEU.0000185583.25420.DF

K. Jo, J. Yeon, K. Kim, P. Jeon, J. Kim et al., Predictors of thromboembolism during coil embolization in patients with unruptured intracranial aneurysm, Acta Neurochirurgica, vol.28, issue.6, pp.1101-1106, 2013.
DOI : 10.1007/s00701-013-1706-0

E. Ft, G. Forbes, and B. Sandok, Complications of cerebral angiography: prospective assessment of risk, AJR. American journal of roentgenology, vol.142, issue.2, pp.247-253, 1984.

A. Soeda, N. Sakai, and H. Sakai, Thromboembolic events associated with Guglielmi detachable coil embolization of asymptomatic cerebral aneurysms: evaluation of 66 consecutive cases with use of diffusionweighted MR imaging, AJNR. American journal of neuroradiology, vol.24, issue.1, pp.127-132, 2003.

L. Pierot, C. Cognard, R. Anxionnat, F. Ricolfi, and C. Investigators, Remodeling Technique for Endovascular Treatment of Ruptured Intracranial Aneurysms Had a Higher Rate of Adequate Postoperative Occlusion than Did Conventional Coil Embolization with Comparable Safety, Radiology, vol.258, issue.2, pp.546-553, 2011.
DOI : 10.1148/radiol.10100894

N. Brooks, A. Turk, D. Niemann, B. Aagaard-kienitz, K. Pulfer et al., Frequency of thromboembolic events associated with endovascular aneurysm treatment: retrospective case series, Journal of Neurosurgery, vol.108, issue.6, pp.1095-1100, 2008.
DOI : 10.3171/JNS/2008/108/6/1095

A. Santillan, Y. Gobin, and J. Mazura, Balloon-assisted coil embolization of intracranial aneurysms is not associated with increased periprocedural complications, Journal of NeuroInterventional Surgery, vol.5, issue.Suppl 3, pp.56-61, 2013.
DOI : 10.1136/neurintsurg-2012-010351

C. Fisher, J. Kistler, and J. Davis, Relation of Cerebral Vasospasm to Subarachnoid Hemorrhage Visualized by Computerized Tomographic Scanning, Neurosurgery, vol.6, issue.1, pp.1-9, 1980.
DOI : 10.1227/00006123-198001000-00001

G. Teasdale, C. Drake, and W. Hunt, A universal subarachnoid hemorrhage scale: report of a committee of the World Federation of Neurosurgical Societies., Journal of Neurology, Neurosurgery & Psychiatry, vol.51, issue.11, p.1457, 1988.
DOI : 10.1136/jnnp.51.11.1457