T. Et, . Biomecaniques, . Peek, C. De-ses, and .. De-young, 35 III-2.5.5. Traitement de surface par immersion de plasma et implantation d'ion (PIII) : 36 III-3 37 III-3.1. Comportement élastique sous contrainte de traction, compression et flexion 37 III-3.1.1. Le module d'élasticité ou module, III-2.5.4. Traitement de surface par plasma à faisceau d'électrons, p.41

P. Synthèse-sur-les-propriétés-mécaniques-du, 43 III-4 DIFFUSION 45 III-4.1. Analyse par éléments finis 45 III-4.2. Résultats des différentes études par analyse d'éléments finis, p.50

B. Dahlgren, S. Teiwik, A. Gröndahl, and K. , Long-term evaluation of Astra Tech and Brånemark implants in patients treated with full-arch bridges. Results after 12-15 years, Clin Oral Implants Res, vol.24, issue.10, pp.1144-51, 2013.

N. Lang, B. Pjetursson, K. Tan, U. Brägger, M. Egger et al., A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. II. Combined tooth-implant-supported FPDs, Clinical Oral Implants Research, vol.21, issue.3, pp.643-53, 2004.
DOI : 10.1034/j.1600-0501.1995.060207.x

T. Albrektsson, G. Zarb, P. Worthington, and A. Eriksson, The long-term efficacy of currently used dental implants: a review and proposed criteria of success

A. Natali, P. Pavan, and A. Ruggero, Analysis of bone-implant interaction phenomena by using a numerical approach, Clinical Oral Implants Research, vol.37, issue.1, pp.67-74, 2006.
DOI : 10.1111/j.1600-0501.2005.01162.x

B. Sotto-maior, C. Lima, A. De, P. Senna, G. Camargos et al., Biomechanical evaluation of subcrestal dental implants with different bone anchorages, Brazilian Oral Research, vol.28, issue.1, 2014.
DOI : 10.1590/1807-3107BOR-2014.vol28.0023

N. Clelland, J. Lee, O. Bimbenet, and A. Gilat, Use of an Axisymmetric Finite Element Method to Compare Maxillary Bone Variables for a Loaded Implant, Journal of Prosthodontics, vol.13, issue.3, pp.183-192, 1993.
DOI : 10.1111/j.1532-849X.1993.tb00405.x

C. Huang, T. Lan, H. Lee, and C. Wang, The Biomechanical Analysis of Relative Position Between Implant and Alveolar Bone: Finite Element Method, Journal of Periodontology, vol.82, issue.3, pp.489-96, 2010.
DOI : 10.1902/jop.2010.100388

P. Brånemark, G. Zarb, and T. Albrektsson, Tissue-integrated prostheses : Osseointegration in clinical dentistry, 1985.

M. Listgarten, N. Lang, H. Schroeder, and A. Schroeder, Periodontal tissues and their counterparts around endosseous implants, Clin Oral Implants Res, 1991.
DOI : 10.1034/j.1600-0501.1991.020101.x

S. Szmukler-moncler, A. Piattelli, G. Favero, and J. Dubruille, Considerations preliminary to the application of early and immediate loading protocols in dental implantology, Clinical Oral Implants Research, vol.11, issue.1, pp.12-25, 2000.
DOI : 10.1034/j.1600-0501.2000.011001012.x

G. Watzek, . Endosseous, V. Choquet, M. Hermans, P. Adriaenssens et al., Scientific and clinical aspects 407 p. 14 Clinical and radiographic evaluation of the papilla level adjacent to single-tooth dental implants. A retrospective study in the maxillary anterior region, J Periodontol, vol.72, issue.10, pp.1364-71, 1996.

S. Szmukler-moncler, H. Salama, Y. Reingewirtz, and J. Dubruille, Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literature, Journal of Biomedical Materials Research, vol.4, issue.2, pp.192-203, 1998.
DOI : 10.1002/(SICI)1097-4636(199822)43:2<192::AID-JBM14>3.0.CO;2-K

R. Nedir, M. Bischof, S. Szmukler-moncler, J. Bernard, and J. Samson, Predicting osseointegration by means of implant primary stability. A resonance-frequency analysis study with delayed and immediately loaded ITI SLA implants, Clinical Oral Implants Research, vol.10, issue.5, pp.520-528, 2004.
DOI : 10.1034/j.1600-0501.2002.130205.x

M. Bischof, R. Nedir, S. Szmukler-moncler, J. Bernard, and J. Samson, Implant stability measurement of delayed and immediately loaded implants during healing

O. Dilek, E. Tezulas, and M. Dincel, Required minimum primary stability and torque values for immediate loading of mini dental implants: an experimental study in nonviable bovine femoral bone, Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology, vol.105, issue.2, pp.20-27, 2008.
DOI : 10.1016/j.tripleo.2007.10.003

M. Cehreli, D. Karasoy, K. Akca, and S. Eckert, Meta-analysis of methods used to assess implant stability, Int J Oral Maxillofac Implants, vol.24, issue.6, pp.1015-1047, 2009.

R. Barewal, T. Oates, N. Meredith, and D. Cochran, Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acidetched surface, Int J Oral Maxillofac Implants, vol.18, issue.5, pp.641-51, 2003.

N. Davarpanah, S. Szmuckler-moncler, P. Khoury, B. Jakubowicz-kohen, and H. Martinez, Manuel d'implantologie clinique 3e édition Concepts, intégration des protocoles et esquisse de nouveaux paradigmes. 3e édition. Rueil-Malmaison: CdP; 2012

S. Nandi, S. Biswas, A. A2-bose, and . Bandyopadhyaysusmita, Chapter 6 -In Vivo Characterization of Biomaterials, Characterization of Biomaterials, pp.255-97, 2013.

T. Albrektsson and C. Johansson, Osteoinduction, osteoconduction and osseointegration, Eur Spine J, vol.10, issue.2, pp.96-101, 2001.
DOI : 10.1007/978-3-642-56071-2_3

O. Ogle, Implant Surface Material, Design, and Osseointegration, Dental Clinics of North America, vol.59, issue.2, pp.505-525
DOI : 10.1016/j.cden.2014.12.003

R. Smeets, B. Stadlinger, F. Schwarz, B. Beck-broichsitter, O. Jung et al., Impact of Dental Implant Surface Modifications on Osseointegration On implant surfaces: a review of current knowledge and opinions, BioMed Res Int. Int J Oral Maxillofac Implants Feb, vol.25, issue.1, pp.63-74, 2010.

R. Schenk and D. Buser, Osseointegration: a reality, Periodontology 2000, vol.9, issue.1, 1998.
DOI : 10.1002/jbm.820291213

S. Khan, M. Ramachandran, S. Kumar, S. Krishnan, V. Sundaram et al., Osseointegration and more???A review of literature, Indian Journal of Dentistry, vol.3, issue.2, pp.72-78
DOI : 10.1016/j.ijd.2012.03.012

G. Giavaresi, M. Fini, A. Cigada, R. Chiesa, G. Rondelli et al., Mechanical and histomorphometric evaluations of titanium implants with different surface treatments inserted in sheep cortical bone, Biomaterials, vol.24, issue.9, 2003.
DOI : 10.1016/S0142-9612(02)00548-3

G. Leventhal, TITANIUM, A METAL FOR SURGERY, The Journal of Bone & Joint Surgery, vol.33, issue.2, 1951.
DOI : 10.2106/00004623-195133020-00021

E. Lautenschlager and P. Monaghan, Titanium and titanium alloys as dental materials, Int Dent J, vol.43, issue.3, pp.245-53, 1993.

M. Andreiotelli, H. Wenz, and R. Kohal, Are ceramic implants a viable alternative to titanium implants? A systematic literature review, Clinical Oral Implants Research, vol.6, issue.(Suppl. 1), pp.32-47, 2009.
DOI : 10.1111/j.1600-0501.2009.01785.x

G. Maccauro, P. Iommetti, F. Muratori, L. Raffaelli, P. Manicone et al., An Overview about Biomedical Applications of Micron and Nano Size Tantalum, Recent Patents on Biotechnology, vol.3, issue.3, pp.157-65, 2009.
DOI : 10.2174/187220809789389153

H. Skinner, Composite Technology for Total Hip Arthroplasty, Clinical Orthopaedics and Related Research, vol.&NA;, issue.235, pp.224-260, 1988.
DOI : 10.1097/00003086-198810000-00022

R. Osman and M. Swain, A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia, Materials, vol.8, issue.3, pp.932-58, 2015.
DOI : 10.3390/ma8030932

M. Mccracken, Dental Implant Materials: Commercially Pure Titanium and Titanium Alloys, Journal of Prosthodontics, vol.11, issue.1, pp.40-43, 1999.
DOI : 10.1016/0021-9290(88)90008-5

H. Emneus, U. Stenram, and J. Baecklund, An X-Ray Spectrographic Investigation of the Soft Tissue Around Titanium and Cobalt Alloy Implants, Acta Orthopaedica Scandinavica, vol.68, issue.1-4, pp.226-262, 1960.
DOI : 10.3109/17453676109149543

H. Wenz, J. Bartsch, S. Wolfart, and M. Kern, Osseointegration and clinical success of zirconia dental implants : a systematic review, Int J Prosthodont, 2008.

Z. Özkurt and E. Kazazo?lu, Zirconia Dental Implants: A Literature Review, Journal of Oral Implantology, vol.37, issue.3, pp.367-76, 2011.
DOI : 10.1563/AAID-JOI-D-09-00079

S. Cowin, Chapter 8 -The mechanical properties of cortical bone, Bone Mechanics. Boca Raton, pp.97-127, 1989.

A. Natali, R. Hart, P. Pavan, and I. Knets, Chapter 1 -Mechanics of bone tissue, In: Dental Biomechanics, pp.1-19, 2003.

J. Brunski, D. Puleo, and N. A. , Biomaterials and biomechanics of oral and maxillofacial implants: current status and future developments, Int J Oral Maxillofac Implants. Feb, vol.15, issue.1, pp.15-46, 2000.

C. Sheets and J. Earthmann, Natural tooth intrusion and reversal in implant-assisted prosthesis: Evidence of and a hypothesis for the occurrence, The Journal of Prosthetic Dentistry, vol.70, issue.6, pp.513-533, 1993.
DOI : 10.1016/0022-3913(93)90265-P

D. Enlow and R. Moyers, 1 Growth and Architecture of the Face, The Journal of the American Dental Association, vol.82, issue.4, pp.763-74, 1939.
DOI : 10.14219/jada.archive.1971.0144

F. Pauwels, Importance of marrow-cavity with respect to the mechanical stress of tubular bones, Zeitschrift f???r Anatomie und Entwicklungsgeschichte, vol.111, issue.1, pp.81-86, 1974.
DOI : 10.1007/BF00519128

H. Frost, Wolff's Law and bone's structural adaptations to mechanical usage: an overview for clinicians, Angle Orthod, vol.64, issue.3, pp.175-88, 1994.

A. Goodship, The Law of Bone Remodelling, J Anat, vol.155, p.217, 1987.

Y. Shibata, Y. Tanimoto, N. Maruyama, and M. Nagakura, A review of improved fixation methods for dental implants. Part II: Biomechanical integrity at bone???implant interface, Journal of Prosthodontic Research, vol.59, issue.2, pp.84-95
DOI : 10.1016/j.jpor.2015.01.003

M. Cehreli, S. Sahin, and K. Akça, Role of mechanical environment and implant design on bone tissue differentiation: current knowledge and future contexts, Journal of Dentistry, vol.32, issue.2, pp.123-155, 2004.
DOI : 10.1016/j.jdent.2003.09.003

S. Sahin, M. Cehreli, and E. Yalçin, The influence of functional forces on the biomechanics of implant-supported prostheses--a review, J Dent, vol.30, pp.7-8271, 2002.

J. Brunski, In vivo bone response to biomechanical loading at the bone/dental-implant interface Adv Dent Res, pp.99-119, 1999.

W. Mihalko, T. May, J. Kay, and W. Krause, FINITE ELEMENT ANALYSIS OF INTERFACE GEOMETRY EFFECTS ON THE CRESTAL BONE SURROUNDING A DENTAL IMPLANT, Implant Dentistry, vol.1, issue.3, pp.212-219, 1992.
DOI : 10.1097/00008505-199200130-00008

C. Rungsiyakull, J. Chen, P. Rungsiyakull, W. Li, M. Swain et al., Bone???s responses to different designs of implant-supported fixed partial dentures, Biomechanics and Modeling in Mechanobiology, vol.6, issue.4, pp.403-414
DOI : 10.1007/s10237-014-0612-6

G. Haïat, H. Wang, and J. Brunski, Effects of Biomechanical Properties of the Bone???Implant Interface on Dental Implant Stability: From In Silico Approaches to the Patient's Mouth, Annual Review of Biomedical Engineering, vol.16, issue.1, pp.187-213, 2014.
DOI : 10.1146/annurev-bioeng-071813-104854

S. Clift, J. Fisher, and C. Watson, Finite element stress and strain analysis of the bone surrounding a dental implant: effect of variations in bone modulus, ARCHIVE: Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 1989-1996 (vols 203-210), vol.206, issue.48, pp.233-274, 1992.
DOI : 10.1243/PIME_PROC_1992_206_295_02

M. Cehreli and K. Akca, Mechanobiology of Bone and Mechanocoupling of Endosseous Titanium Oral Implants, Journal of Long-Term Effects of Medical Implants, vol.15, issue.2, pp.139-52, 2005.
DOI : 10.1615/JLongTermEffMedImplants.v15.i2.30

S. Kurtz and J. Devine, PEEK biomaterials in trauma, orthopedic, and spinal implants, Biomaterials, vol.28, issue.32, pp.4845-69, 2007.
DOI : 10.1016/j.biomaterials.2007.07.013

J. Cougoulic, C. Sedarat, and M. Harmand, Un nouveau matériau " metal-free " en implantologie : le Biopik. Implantologie, pp.95-100, 2010.

A. Schwitalla and W. Müller, PEEK Dental Implants: A Review of the Literature, Journal of Oral Implantology, vol.39, issue.6, pp.743-752, 2013.
DOI : 10.1563/AAID-JOI-D-11-00002

C. Morrison, R. Macnair, C. Macdonald, A. Wykman, I. Goldie et al., In vitro biocompatibility testing of polymers for orthopaedic implants using cultured fibroblasts and osteoblasts, Biomaterials, vol.16, issue.13, pp.987-92, 1995.
DOI : 10.1016/0142-9612(95)94906-2

D. Williams, A. Mcnamara, and R. Turner, Potential of polyetheretherketone (PEEK) and carbon-fibre-reinforced PEEK in medical applications, Journal of Materials Science Letters, vol.2, issue.2, pp.188-90, 1987.
DOI : 10.1007/BF01728981

S. Najeeb, M. Zafar, Z. Khurshid, and F. Siddiqui, Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics, Journal of Prosthodontic Research, vol.60, issue.1, pp.12-21, 2016.
DOI : 10.1016/j.jpor.2015.10.001

M. Wiesli and M. Özcan, High-Performance Polymers and Their Potential Application as Medical and Oral Implant Materials, Implant Dentistry, 2015.
DOI : 10.1097/ID.0000000000000285

C. Li, C. Vannabouathong, S. Sprague, and M. Bhandari, The Use of Carbon-Fiber-Reinforced (CFR) PEEK Material in Orthopedic Implants: A Systematic Review, Clinical Medicine Insights: Arthritis and Musculoskeletal Disorders
DOI : 10.4137/CMAMD.S20354

S. Ferguson, J. Visser, and A. Polikeit, The long-term mechanical integrity of non-reinforced PEEK-OPTIMA polymer for demanding spinal applications: experimental and finite-element analysis. Eur Spine J Off Publ Eur Spine Soc Eur Spinal Deform Soc Eur Sect Cerv Spine Res Soc, Feb, vol.15, issue.2, pp.149-56, 2006.

J. Sarot, C. Contar, A. Cruz, . Da, and R. De-souza-magini, Evaluation of the stress distribution in CFR-PEEK dental implants by the three-dimensional finite element method, Journal of Materials Science: Materials in Medicine, vol.19, issue.7, pp.2079-85, 2010.
DOI : 10.1007/s10856-010-4084-7

A. Schwitalla, M. Abou-emara, T. Spintig, J. Lackmann, and W. Müller, Finite element analysis of the biomechanical effects of PEEK dental implants on the peri-implant bone, Journal of Biomechanics, vol.48, issue.1, pp.1-7, 2015.
DOI : 10.1016/j.jbiomech.2014.11.017

W. Lee, J. Koak, Y. Lim, S. Kim, H. Kwon et al., Stress shielding and fatigue limits of poly-ether-ether-ketone dental implants, Journal of Biomedical Materials Research Part B: Applied Biomaterials, vol.18, issue.4
DOI : 10.1002/jbm.b.32669

A. Schwitalla, T. Spintig, I. Kallage, and W. Müller, Flexural behavior of PEEK materials for dental application, Dental Materials, vol.31, issue.11, 2015.
DOI : 10.1016/j.dental.2015.08.151

A. Schwitalla, T. Spintig, I. Kallage, and W. Müller, Pressure behavior of different PEEK materials for dental implants, Journal of the Mechanical Behavior of Biomedical Materials, vol.54, 2016.
DOI : 10.1016/j.jmbbm.2015.10.003

G. Zhang, R. Latour, J. Kennedy, D. Schutte, H. Friedman et al., Long-term compressive property durability of carbon fibre-reinforced polyetheretherketone composite in physiological saline, Biomaterials, vol.17, issue.8, pp.781-790, 1996.
DOI : 10.1016/0142-9612(96)81415-3

K. Kwarteng and C. Stark, Carbon fiber reinforced PEEK (APC-2/AS-4) composites for orthopaedic implants, SAMPE Q, vol.22, issue.1, pp.10-14, 1990.

S. Brown, R. Hastings, J. Mason, and A. Moet, Characterization of short-fibre reinforced thermoplastics for fracture fixation devices, Biomaterials, vol.11, issue.8, 1990.
DOI : 10.1016/0142-9612(90)90075-2

A. Richard, K. Merritt, S. Brown, A. Moet, and A. Steffee, Evaluation du Polyetherethercetone (PEEK) en implantologie orale : intérêts, limites et perspectives. [Revue de littérature] In vitro biocompatibility of polyetheretherketone and polysulfone composites, J Biomed Mater Res, 1990.

D. Blundell and B. Osborn, The morphology of poly(aryl-ether-ether-ketone), Polymer, vol.24, issue.8
DOI : 10.1016/0032-3861(83)90144-1

F. Suska, O. Omar, L. Emanuelsson, M. Taylor, P. Gruner et al., Enhancement of CRF-PEEK osseointegration by plasma-sprayed hydroxyapatite: A rabbit model, Journal of Biomaterials Applications, vol.235, issue.2, pp.234-276
DOI : 10.1016/j.biomaterials.2007.07.013

S. Wheeler, Eight-year clinical retrospective study of titanium plasma-sprayed and hydroxyapatite-coated cylinder implants, Implant Dentistry, vol.6, issue.1, 1996.
DOI : 10.1097/00008505-199700610-00042

I. Nakahara, M. Takao, S. Bandoh, N. Bertollo, W. Walsh et al., In vivo implant fixation of carbon fiber-reinforced PEEK hip prostheses in an ovine model, Journal of Orthopaedic Research, vol.31, issue.3, pp.485-92, 2013.
DOI : 10.1002/jor.22251

I. Nakahara, M. Takao, T. Goto, C. Ohtsuki, S. Hibino et al., Interfacial shear strength of bioactive-coated carbon fiber reinforced polyetheretherketone after in vivo implantation, Journal of Orthopaedic Research, vol.27, issue.10, pp.1618-1643, 2012.
DOI : 10.1002/jor.22115

S. Cook and A. Rust-dawicki, Preliminary evaluation of titanium-coated PEEK dental implants, J Oral Implantol, vol.21, issue.3, pp.176-81, 1995.

S. Barkarmo, M. Andersson, F. Currie, P. Kjellin, J. R. Johansson et al., Enhanced bone healing around nanohydroxyapatite-coated polyetheretherketone implants: An experimental study in rabbit bone, Journal of Biomaterials Applications, vol.29, issue.5, pp.737-784, 2014.
DOI : 10.1177/0885328214542854

P. Johansson, J. R. Kjellin, P. Currie, F. Chrcanovic, B. Wennerberg et al., Biomechanical evaluation and surface characterization of a nano-modified surface on PEEK implants: a study in the rabbit tibia, International Journal of Nanomedicine, vol.9, pp.3903-3914, 2014.
DOI : 10.2147/IJN.S60387

J. Waser-althaus, A. Salamon, M. Waser, C. Padeste, M. Kreutzer et al., Differentiation of human mesenchymal stem cells on plasma-treated polyetheretherketone, Journal of Materials Science: Materials in Medicine, vol.281, issue.34, pp.515-540, 2014.
DOI : 10.1007/s10856-013-5072-5

S. Randolph, J. Fowlkes, and P. Rack, Focused, Nanoscale Electron-Beam-Induced Deposition and Etching, Critical Reviews in Solid State and Materials Sciences, vol.7, issue.3, pp.55-89, 2006.
DOI : 10.1063/1.111912

C. Han, E. Lee, H. Kim, Y. Koh, K. Kim et al., The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties, Biomaterials, vol.31, issue.13, pp.3465-70, 2010.
DOI : 10.1016/j.biomaterials.2009.12.030

J. Mantese, I. Brown, N. Cheung, and G. Collins, Plasma-Immersion Ion Implantation, MRS Bulletin, vol.84, issue.69, pp.52-58, 1996.
DOI : 10.1557/S0883769400035727

J. Duyck, H. Rønold, V. Oosterwyck, H. Naert, I. et al., The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study, Clinical Oral Implants Research, vol.1, issue.3, pp.207-225, 2001.
DOI : 10.1016/0142-9612(96)80750-2

T. Brown, D. Pedersen, M. Gray, R. Brand, and C. Rubin, Toward an identification of mechanical parameters initiating periosteal remodeling: A combined experimental and analytic approach, Journal of Biomechanics, vol.23, issue.9, pp.893-905, 1990.
DOI : 10.1016/0021-9290(90)90354-6

. Vu, Le Directeur de l'UFR des Sciences Odontologiques