F. Weine, Endodontic Therapy, 6e. 6 edition, 2003.

F. Vertucci, A. Seelig, and R. Gillis, Root canal morphology of the human maxillary second premolar. Oral Surg Oral Med Oral Pathol, pp.456-64, 1974.

M. Cali?kan, Y. Pehlivan, F. Sepetçio?lu, M. Türkün, and S. Tuncer, Root canal morphology of human permanent teeth in a Turkish population, Journal of Endodontics, vol.21, issue.4, pp.200-204, 1995.
DOI : 10.1016/S0099-2399(06)80566-2

M. Trope, L. Elfenbein, and L. Tronstad, Mandibular premolars with more than one root canal in different race groups, Journal of Endodontics, vol.12, issue.8, pp.343-348, 1986.
DOI : 10.1016/S0099-2399(86)80035-8

H. Peiris, T. Pitakotuwage, M. Takahashi, K. Sasaki, and E. Kanazawa, Root canal morphology of mandibular permanent molars at different ages, International Endodontic Journal, vol.14, issue.10, 2008.
DOI : 10.2330/joralbiosci1965.14.156

Y. Kuttler, Microscopic investigation of root apexes, The Journal of the American Dental Association, vol.50, issue.5, 1939.
DOI : 10.14219/jada.archive.1955.0099

M. Hulsmann and E. Schafer, Problems in Endodontics: Etiology, Diagnosis, and Treatment

P. Dummer, J. Mcginn, and D. Rees, The position and topography of the apical canal constriction and apical foramen, International Endodontic Journal, vol.11, issue.4, pp.192-200, 1984.
DOI : 10.14219/jada.archive.1955.0099

D. Green, Stereomicroscopic study of 700 root apices of maxillary and mandibular posterior teeth. Oral Surg Oral Med Oral Pathol, pp.728-761, 1960.

J. Gutierrez and P. Aguayo, Apical foraminal openings in human teeth. Number and location

M. Versiani, H. Ahmed, M. Sousa-neto, . De, G. De-deus et al., Unusual Deviation of the Main Foramen from the Root Apex, Brazilian Dental Journal, vol.40, issue.5, pp.589-91, 2016.
DOI : 10.1016/j.joen.2014.07.034

M. Pons, S. Seltzer, W. Soltanoff, I. Sinai, A. Goldenberg et al., Préparation en rotation continue associée a une localisation électronique de l'apex : étude in vitro de deux appareils Biologic Aspects of Endodontics Part III. Periapical Tissue Reactions to Root Canal Instrumentation, J Endod, vol.17, 1999.

E. Ponce, V. Fernández, and J. , The Cemento-Dentino-Canal Junction, the Apical Foramen, and the Apical Constriction: Evaluation by Optical Microscopy, Journal of Endodontics, vol.29, issue.3, pp.214-223, 2003.
DOI : 10.1097/00004770-200303000-00013

J. Forsberg, Estimation of the root filling length with the paralleling and bisecting-angle techniques performed by undergraduate students, International Endodontic Journal, vol.14, issue.6, pp.282-288, 1987.
DOI : 10.14219/jada.archive.1963.0349

T. Gound, L. Dubois, S. Biggs, A. Farida, E. Maryam et al., Factors that affect the rate of retakes for endodontic treatment radiographs Oral Surg Oral Med Oral Pathol A comparison between conventional and digital radiography in root canal working length determination, Indian J Dent Res, vol.7724, issue.52, pp.514-522, 1994.

A. Elayouti, R. Weiger, and C. Löst, Frequency of Overinstrumentation with an Acceptable Radiographic Working Length, Journal of Endodontics, vol.27, issue.1, pp.49-52, 2001.
DOI : 10.1097/00004770-200101000-00018

M. Nekoofar, M. Ghandi, S. Hayes, and P. Dummer, The fundamental operating principles of electronic root canal length measurement devices, International Endodontic Journal, vol.1, issue.8, 2006.
DOI : 10.1097/00004770-200308000-00002

S. Simon, W. Pertot, and O. Laboux, Endodontie : Tome 1, Traitements

J. Ushiyama, New principle and method for measuring the root canal length, Journal of Endodontics, vol.9, issue.3
DOI : 10.1016/S0099-2399(83)80105-8

L. Huang, An experimental study of the principle of electronic root canal measurement, Journal of Endodontics, vol.13, issue.2
DOI : 10.1016/S0099-2399(87)80156-5

C. Kobayashi and H. Suda, New electronic canal measuring device based on the ratio method, Journal of Endodontics, vol.20, issue.3
DOI : 10.1016/S0099-2399(06)80053-1

K. Wrbas, A. Ziegler, M. Altenburger, and J. Schirrmeister, In vivo comparison of working length determination with two electronic apex locators, International Endodontic Journal, vol.22, issue.2, pp.133-141, 2007.
DOI : 10.1097/00004770-200308000-00002

A. Tinaz, M. Maden, C. Aydin, and E. Türköz, The accuracy of three different electronic root canal measuring devices: An in vitro evaluation., Journal of Oral Science, vol.44, issue.2, pp.91-96, 2002.
DOI : 10.2334/josnusd.44.91

A. Welk, J. Baumgartner, and J. Marshall, An In Vivo Comparison of Two Frequency-based Electronic Apex Locators, Journal of Endodontics, vol.29, issue.8, pp.497-500, 2003.
DOI : 10.1097/00004770-200308000-00002

N. Gomes and R. Bernardes, An ex vivo comparison of root canal length determination by three electronic apex locators at positions short of the apical foramen, pp.57-61, 2010.

B. Vasconcelos, . De, L. Frota, T. Souza, A. De et al., Evaluation of the Maintenance of the Apical Limit during??Instrumentation with Hybrid Equipment in??Rotary??and??Reciprocating Modes, Journal of Endodontics, vol.41, issue.5, pp.682-687
DOI : 10.1016/j.joen.2014.11.029

A. Elayouti, I. Kimionis, A. Chu, and C. Löst, Determining the apical terminus of root-end resected teeth using three modern apex locators: a comparative ex vivo study, International Endodontic Journal, vol.25, issue.11, 2005.
DOI : 10.1067/moe.2000.106344

E. Akisue, S. Gratieri, F. Barletta, C. Caldeira, R. Grazziotin-soares et al., Not All Electronic Foramen Locators Are Accurate in Teeth with Enlarged Apical Foramina: An In??Vitro Comparison of 5 Brands, Journal of Endodontics, vol.40, issue.1, pp.109-121
DOI : 10.1016/j.joen.2013.09.032

C. Dunlap, N. Remeikis, E. Begole, and C. Rauschenberger, An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals, Journal of Endodontics, vol.24, issue.1, 1998.
DOI : 10.1016/S0099-2399(98)80214-8

E. Akisue, G. Gavini, and J. De-figueiredo, Influence of pulp vitality on length determination by using the Elements Diagnostic Unit and Apex Locator. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, pp.129-161, 2007.

D. Assunção, F. De-albuquerque, D. De-queiroz, and L. Ferreira, The Ability of Two Apex Locators to Locate the Apical Foramen: An In Vitro Study, Journal of Endodontics, vol.32, issue.6, pp.560-562, 2006.
DOI : 10.1016/j.joen.2005.11.011

D. Altunbas, A. Kustarci, D. Arslan, and K. Er, In vitro comparison of four different electronic apex locators to determine the major foramen using the clearing technique, Niger J Clin Pract

J. Barthelemy, L. Gregor, I. Krejci, J. Wataha, and S. Bouillaguet, Accuracy of electronic apex locater-controlled handpieces, Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology, vol.107, issue.3, pp.437-478, 2009.
DOI : 10.1016/j.tripleo.2008.11.010

A. Ku?tarci, D. Arslan, and D. Altunba?, In vitro comparison of working length determination using three different electronic apex locators, Dent Res J, vol.11, issue.5, pp.568-73, 2014.

A. Elayouti, R. Weiger, C. Löst, E. De-camargo, R. Zapata et al., The ability of root ZX apex locator to reduce the frequency of overestimated radiographic working length Influence of preflaring on the accuracy of length determination with four electronic apex locators, J Endod. Feb J Endod, vol.2835, issue.29, pp.116-125, 2002.

W. Meares and H. Steiman, The Influence of Sodium Hypochlorite Irrigation on the Accuracy of the Root ZX Electronic Apex Locator, Journal of Endodontics, vol.28, issue.8, pp.595-603, 2002.
DOI : 10.1097/00004770-200208000-00008

A. Waszkiewicz, The Effect of File Size and Type and Irrigation Solutions on the Accuracy of Electronic Apex Locators: An In Vitro Study on Canine Teeth Critical diameter of apical foramen and of file size using the Root ZX apex locator: an in vitro study, BioMed Res Int. J Endod, vol.2016, pp.8594087-8594136, 2011.

A. Ebrahim, R. Wadachi, and H. Suda, Ex vivo evaluation of the ability of four different electronic apex locators to determine the working length in teeth with various foramen diameters

Z. Bahrololoomi, A. Soleymani, J. Modaresi, M. Imanian, and M. Lotfian, Accuracy of an Electronic Apex Locator for Working Length Determination in Primary Anterior Teeth, J Dent Tehran Iran. 2015, vol.12, issue.4, pp.243-251

L. Kumar, N. Sreelakshmi, E. Reddy, M. Manjula, S. Rani et al., Clinical Evaluation of Conventional Radiography, Radiovisiography, and an Electronic Apex Locator in Determining the Working Length in Primary Teeth. Pediatr Dent, Feb, vol.38, issue.1, pp.37-41, 2016.

F. Oznurhan, M. Ünal, A. Kapdan, C. Ozturk, and S. Aksoy, Clinical evaluation of apex locator and radiography in primary teeth, International Journal of Paediatric Dentistry, vol.2, issue.3, pp.199-203
DOI : 10.1007/s40368-013-0011-1

. Vu, Le Directeur de l'UFR des Sciences Odontologiques