A. Miller, J. W. Sleigh, J. Barnard, and D. A. Steyn-ross, Does bispectral analysis of the electroencephalogram add anything but complexity???, British Journal of Anaesthesia, vol.92, issue.1, pp.8-13, 2004.
DOI : 10.1093/bja/aeh003

G. Schneider, S. Schöniger, and E. Kochs, Does bispectral analysis add anything but complexity? BIS sub-components may be superior to BIS for detection of awareness, British Journal of Anaesthesia, vol.93, issue.4, pp.596-597, 2004.
DOI : 10.1093/bja/aeh612

M. S. Avidan, Anesthesia Awareness and the Bispectral Index, New England Journal of Medicine, vol.358, issue.11, pp.1097-1108, 2008.
DOI : 10.1056/NEJMoa0707361

L. A. Kearse, P. Manberg, N. Chamoun, F. Debros, and A. Zaslavsky, Bispectral Analysis of the Electroencephalogram Correlates with Patient Movement to Skin Incision during Propofol/Nitrous Oxide Anesthesia, Anesthesiology, vol.81, issue.6, pp.1365-1370, 1994.
DOI : 10.1097/00000542-199412000-00010

L. A. Kearse, Bispectral Analysis of the Electroencephalogram Predicts Conscious Processing of Information during Propofol Sedation and Hypnosis, Anesthesiology, vol.88, issue.1, pp.25-34, 1998.
DOI : 10.1097/00000542-199801000-00007

K. Leslie, Prediction of Movement during Propofol/Nitrous Oxide Anesthesia, Anesthesiology, vol.84, issue.1, pp.52-63, 1996.
DOI : 10.1097/00000542-199601000-00006

T. Katoh, A. Suzuki, and K. Ikeda, Electroencephalographic Derivatives as a Tool for Predicting the Depth of Sedation and Anesthesia Induced by Sevoflurane, Anesthesiology, vol.88, issue.3, pp.642-650, 1998.
DOI : 10.1097/00000542-199803000-00014

S. C. Hoymork, J. Raeder, B. Grimsmo, and P. A. Steen, Bispectral index, serum drug concentrations and emergence associated with individually adjusted target???controlled infusions of remifentanil and propofol for laparoscopic surgery???, BJA: British Journal of Anaesthesia, vol.91, issue.6, pp.773-780, 2003.
DOI : 10.1093/bja/aeg258

T. Sakai, H. Singh, W. D. Mi, T. Kudo, and A. Matsuki, The effect of ketamine on clinical endpoints of hypnosis and EEG variables during propofol infusion, Acta Anaesthesiologica Scandinavica, vol.43, issue.2, pp.212-216, 1999.
DOI : 10.1034/j.1399-6576.1999.430216.x

M. Suzuki, H. L. Edmonds, K. Tsueda, A. L. Malkani, and C. S. Roberts, Effect of ketamine on bispectral index and levels of sedation, The Journal of Clinical Monitoring and Computing, vol.14, issue.5, p.373, 1998.
DOI : 10.1023/A:1009975701184

S. Ahmad, M. Yilmaz, R. Marcus, S. Glisson, and A. Kinsella, Impact of Bispectral Index Monitoring on Fast Tracking of Gynecologic Patients Undergoing Laparoscopic Surgery, Anesthesiology, vol.98, issue.4, pp.849-852, 2003.
DOI : 10.1097/00000542-200304000-00010

J. Wong, D. Song, H. Blanshard, D. Grady, and F. Chung, Le titrage de l???isoflurane ?? l???aide du BIS peut h??ter la r??cup??ration des patients ??g??s en chirurgie orthop??dique, Canadian Journal of Anesthesia/Journal canadien d'anesth??sie, vol.86, issue.1, pp.13-18, 2002.
DOI : 10.1093/bja/82.6.867

H. Ba?ar, S. Ozcan, U. Buyukkocak, S. Akpinar, and A. Apan, Effect of bispectral index monitoring on sevoflurane consumption, European Journal of Anaesthesiology, vol.20, issue.5, pp.396-400, 2003.
DOI : 10.1097/00003643-200305000-00008

A. Hachero, Influence of bispectral index monitoring on fentanyl requirements during total intravenous anesthesia for major gynecological surgery], Rev. Esp. Anestesiol. Reanim, vol.48, pp.364-369, 2001.

P. S. Myles, K. Leslie, J. Mcneil, A. Forbes, and M. T. Chan, Bispectral index monitoring to prevent awareness during anaesthesia: the B-Aware randomised controlled trial, The Lancet, vol.363, issue.9423, pp.1757-1763, 2004.
DOI : 10.1016/S0140-6736(04)16300-9

P. S. Myles, K. Leslie, and A. Forbes, Anesthesia awareness and the bispectral index, N. Engl. J. Med, vol.359, pp.428-429, 2008.

E. Gürses, H. Sungurtekin, E. Tomatir, and H. Dogan, Assessing propofol induction of anesthesia dose using bispectral index analysis, Anesth. Analg, vol.98, pp.128-131, 2004.

S. S. Liu, Effects of Bispectral Index Monitoring on Ambulatory Anesthesia, Anesthesiology, vol.101, issue.2, pp.311-315, 2004.
DOI : 10.1097/00000542-200408000-00010

Y. Punjasawadwong, A. Phongchiewboon, and N. Bunchungmongkol, Bispectral index for improving anaesthetic delivery and postoperative recovery, Cochrane Database Syst. Rev, p.3843, 2014.
DOI : 10.1002/14651858.cd003843

Y. Morimoto, Efficacy of bispectral index monitoring in improving anesthetic management, economics, and use of the operating theater], Masui, vol.51, pp.862-868, 2002.

Z. S. Messieha, R. C. Ananda, W. E. Hoffman, I. C. Punwani, and H. M. Koenig, Bispectral Index System (BIS) monitoring reduces time to discharge in children requiring intramuscular sedation and general anesthesia for outpatient dental rehabilitation, Pediatr. Dent, vol.26, pp.256-260, 2004.

J. Mayer, J. Boldt, A. Schellhaass, B. Hiller, and S. W. Suttner, Bispectral Index-Guided General Anesthesia in Combination with Thoracic Epidural Analgesia Reduces Recovery Time in Fast-Track Colon Surgery, Anesthesia & Analgesia, vol.104, issue.5, pp.1145-1149, 2007.
DOI : 10.1213/01.ane.0000260566.39244.bd

C. Zhang, Bispectral index monitoring prevent awareness during total intravenous anesthesia: a prospective, randomized, double-blinded, multicenter controlled trial, Chin. Med. J. (Engl.), vol.124, pp.3664-3669, 2011.

O. Connor and M. F. , BIS monitoring to prevent awareness during general anesthesia, Anesthesiology, vol.94, pp.520-522, 2001.

T. G. Monk, V. Saini, B. C. Weldon, and J. C. Sigl, Anesthetic Management and One-Year Mortality After Noncardiac Surgery, Anesthesia & Analgesia, vol.100, issue.1, pp.4-10, 2005.
DOI : 10.1213/01.ANE.0000147519.82841.5E

M. Lindholm, Mortality Within 2 Years After Surgery in Relation to Low Intraoperative Bispectral Index Values and Preexisting Malignant Disease, Anesthesia & Analgesia, vol.108, issue.2, pp.508-512, 2009.
DOI : 10.1213/ane.0b013e31818f603c

URL : http://pdfs.journals.lww.com/anesthesia-analgesia/2009/02000/Mortality_Within_2_Years_After_Surgery_in_Relation.19.pdf?token=method|ExpireAbsolute;source|Journals;ttl|1505599788557;payload|mY8D3u1TCCsNvP5E421JYK6N6XICDamxByyYpaNzk7FKjTaa1Yz22MivkHZqjGP4kdS2v0J76WGAnHACH69s21Csk0OpQi3YbjEMdSoz2UhVybFqQxA7lKwSUlA502zQZr96TQRwhVlocEp/sJ586aVbcBFlltKNKo+tbuMfL73hiPqJliudqs17cHeLcLbV/CqjlP3IO0jGHlHQtJWcICDdAyGJMnpi6RlbEJaRheGeh5z5uvqz3FLHgPKVXJzdOHIHwDOSay4QvwGGy628k/2/MiBUOOH99oHXMHNiTQc/rQr4Edt+WzppAdsOY+z8;hash|mD5BTHpgmYWC0zcYlqoMbQ==

K. Leslie and T. G. Short, Low Bispectral Index Values and Death, Anesthesia & Analgesia, vol.113, issue.3, pp.660-663, 2011.
DOI : 10.1213/ANE.0b013e31822401cc

URL : http://pdfs.journals.lww.com/anesthesia-analgesia/2011/09000/Low_Bispectral_Index_Values_and_Death___The.35.pdf?token=method|ExpireAbsolute;source|Journals;ttl|1504251041675;payload|mY8D3u1TCCsNvP5E421JYK6N6XICDamxByyYpaNzk7FKjTaa1Yz22MivkHZqjGP4kdS2v0J76WGAnHACH69s21Csk0OpQi3YbjEMdSoz2UhVybFqQxA7lKwSUlA502zQZr96TQRwhVlocEp/sJ586aVbcBFlltKNKo+tbuMfL73hiPqJliudqs17cHeLcLbV/CqjlP3IO0jGHlHQtJWcICDdAyGJMnpi6RlbEJaRheGeh5z5uvqz3FLHgPKVXJzdOHIHwDOSay4QvwGGy628k8mZmI/xAt9dx5SpYsptEMqzbckvX9e+S93SN9kMGnoo;hash|+3LNmv0dwYswQvu76c0B6Q==

M. D. Kertai, Bispectral Index Monitoring, Duration of Bispectral Index Below 45, Patient Risk Factors, and Intermediate-term Mortality after Noncardiac Surgery in the B-Unaware Trial, Anesthesiology, vol.114, issue.3, pp.545-556, 2011.
DOI : 10.1097/ALN.0b013e31820c2b57

M. T. Chan, BIS-guided Anesthesia Decreases Postoperative Delirium and Cognitive Decline, Journal of Neurosurgical Anesthesiology, vol.25, issue.1, pp.33-42, 2013.
DOI : 10.1097/ANA.0b013e3182712fba

URL : http://pdfs.journals.lww.com/jnsa/2013/01000/BIS_guided_Anesthesia_Decreases_Postoperative.5.pdf?token=method|ExpireAbsolute;source|Journals;ttl|1503046390970;payload|mY8D3u1TCCsNvP5E421JYK6N6XICDamxByyYpaNzk7FKjTaa1Yz22MivkHZqjGP4kdS2v0J76WGAnHACH69s21Csk0OpQi3YbjEMdSoz2UhVybFqQxA7lKwSUlA502zQZr96TQRwhVlocEp/sJ586aVbcBFlltKNKo+tbuMfL73hiPqJliudqs17cHeLcLbV/CqjlP3IO0jGHlHQtJWcICDdAyGJMnpi6RlbEJaRheGeh5z5uvqz3FLHgPKVXJzd/sQcFjxTET4VEr6B2TitIEZL+n2YwB39DkSHZ8ohWFA=;hash|4/w9Z20V5r18PmoVHB8snA==

F. M. Radtke, Monitoring depth of anaesthesia in a randomized trial decreases the rate of postoperative delirium but not postoperative cognitive dysfunction, British Journal of Anaesthesia, vol.110, issue.suppl 1, pp.98-105, 2013.
DOI : 10.1093/bja/aet055

F. Lagneau, M. Tod, and J. Marty, Applications cliniques de la pharmacologie des agents anesth??siques intraveineux (hypnotiques et morphiniques), Annales Fran??aises d'Anesth??sie et de R??animation, vol.23, issue.10, pp.986-997, 2004.
DOI : 10.1016/j.annfar.2004.07.015

B. Marsh, M. White, N. Morton, and G. N. Kenny, PHARMACOKINETIC MODEL DRIVEN INFUSION OF PROPOFOL IN CHILDREN, BJA: British Journal of Anaesthesia, vol.67, issue.1, pp.41-48, 1991.
DOI : 10.1093/bja/67.1.41

T. W. Schnider, The Influence of Method of Administration and Covariates on the Pharmacokinetics of Propofol in Adult Volunteers, Anesthesiology, vol.88, issue.5, pp.1170-1182, 1998.
DOI : 10.1097/00000542-199805000-00006

C. F. Minto, T. W. Schnider, and S. L. Shafer, Pharmacokinetics and Pharmacodynamics of Remifentanil, Anesthesiology, vol.86, issue.1, pp.24-33, 1997.
DOI : 10.1097/00000542-199701000-00005

S. Passot, Target-Controlled Versus Manually-Controlled Infusion of Propofol for Direct Laryngoscopy and Bronchoscopy, Anesthesia & Analgesia, vol.94, issue.5, pp.1212-1216, 2002.
DOI : 10.1097/00000539-200205000-00030

S. Passot, A Comparison of Target- and Manually Controlled Infusion Propofol and Etomidate/Desflurane Anesthesia in Elderly Patients Undergoing Hip Fracture Surgery, Anesthesia & Analgesia, vol.100, issue.5, pp.1338-1342, 2005.
DOI : 10.1213/01.ANE.0000149542.04833.55

C. Dussaussoy, Automated titration of propofol and remifentanil decreases the anesthesiologist???s workload during vascular or thoracic surgery: a randomized prospective study, Journal of Clinical Monitoring and Computing, vol.53, issue.1, pp.35-40, 2014.
DOI : 10.1007/s00134-012-2762-2

N. Liu, Administration automatique du propofol et du r??mifentanil selon l???indice bispectral pendant des bronchoscopes rigides: une ??tude randomis??e, Canadian Journal of Anesthesia/Journal canadien d'anesth??sie, vol.89, issue.9, pp.881-887, 2013.
DOI : 10.1097/00000542-199810000-00023

N. Liu, Closed-Loop Coadministration of Propofol and Remifentanil Guided by Bispectral Index, Anesthesia & Analgesia, vol.112, issue.3, pp.546-557, 2011.
DOI : 10.1213/ANE.0b013e318205680b

J. B. Bijker, Intraoperative Hypotension and Perioperative Ischemic Stroke after General Surgery, Anesthesiology, vol.116, issue.3, pp.658-664, 2012.
DOI : 10.1097/ALN.0b013e3182472320

L. Y. Sun, D. N. Wijeysundera, G. A. Tait, and W. S. Beattie, Association of Intraoperative Hypotension with Acute Kidney Injury after Elective Noncardiac Surgery, Anesthesiology, vol.123, issue.3, pp.515-523, 2015.
DOI : 10.1097/ALN.0000000000000765

T. G. Monk, Association between Intraoperative Hypotension and Hypertension and 30-day Postoperative Mortality in Noncardiac Surgery, Anesthesiology, vol.123, issue.2, pp.307-319, 2015.
DOI : 10.1097/ALN.0000000000000756

M. Walsh, Relationship between Intraoperative Mean Arterial Pressure and Clinical Outcomes after Noncardiac Surgery, Anesthesiology, vol.119, issue.3, pp.507-515, 2013.
DOI : 10.1097/ALN.0b013e3182a10e26

S. D. Kristensen, ESA Guidelines on non-cardiac surgery: cardiovascular assessment and management: The Joint Task Force on noncardiac surgery: cardiovascular assessment and management of the European Society of, ESC Cardiology, 2014.

K. Yoshitani, M. Kawaguchi, M. Takahashi, K. Kitaguchi, and H. Furuya, Plasma propofol concentration and EEG burst suppression ratio during normothermic cardiopulmonary bypass, British Journal of Anaesthesia, vol.90, issue.2, pp.122-126, 2003.
DOI : 10.1093/bja/aeg010

URL : https://academic.oup.com/bja/article-pdf/90/2/122/682313/aeg010.pdf

M. Hayashida, Effects of Deep Hypothermic Circulatory Arrest With Retrograde Cerebral Perfusion on Electroencephalographic Bispectral Index and Suppression Ratio, Journal of Cardiothoracic and Vascular Anesthesia, vol.21, issue.1, pp.61-67, 2007.
DOI : 10.1053/j.jvca.2006.02.029

N. Liu, T. Chazot, C. Mutter, and M. Fischler, Elevated Burst Suppression Ratio: The Possible Role of Hypoxemia, Anesthesia & Analgesia, vol.103, issue.6, pp.1609-1610, 2006.
DOI : 10.1213/01.ane.0000246268.58067.99

A. Declerck, N. Liu, T. Chazot, and M. Fischler, BIS values during resuscitation: the role of the suppression ratio (case report), Journal of Clinical Monitoring and Computing, vol.36, issue.5, pp.307-309, 2009.
DOI : 10.1007/s10877-009-9197-5

N. Umegaki, A marked decrease in bispectral index with elevation of suppression ratio by cervical haematoma reducing cerebral perfusion pressure, Journal of Clinical Neuroscience, vol.10, issue.6, pp.694-696, 2003.
DOI : 10.1016/j.jocn.2002.11.001

M. Misis, J. G. Raxach, H. P. Molto, S. M. Vega, and P. S. Rico, Bispectral Index Monitoring for Early Detection of Brain Death, Transplantation Proceedings, vol.40, issue.5, pp.1279-1281, 2008.
DOI : 10.1016/j.transproceed.2008.03.145

E. N. Brown, R. Lydic, and N. Schiff, General Anesthesia, Sleep, and Coma, New England Journal of Medicine, vol.363, issue.27, pp.2638-2650, 2010.
DOI : 10.1056/NEJMra0808281

URL : https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3162622/pdf

M. Hayashida, Detection of cerebral hypoperfusion with bispectral index during paediatric cardiac surgery, British Journal of Anaesthesia, vol.90, issue.5, pp.694-698, 2003.
DOI : 10.1093/bja/aeg107

P. S. Myles, Bispectral index monitoring in ischemic-hypoxic brain injury, J. Extra. Corpor. Technol, vol.41, pp.15-19, 2009.

J. Villacorta, Perioperative cerebral ischaemia in cardiac surgery and BIS, Anaesth. Intensive Care, vol.33, pp.514-517, 2005.

P. G. Goodman, A. R. Mehta, and M. R. Castresana, Predicting ischemic brain injury after intraoperative cardiac arrest during cardiac surgery using the BIS monitor, Journal of Clinical Anesthesia, vol.21, issue.8, pp.609-612, 2009.
DOI : 10.1016/j.jclinane.2009.01.014

S. Nebout, Int??r??t du monitorage de l???index bispectral (BIS) pour la d??tection pr??coce des hypoperfusions c??r??brales, Annales Fran??aises d'Anesth??sie et de R??animation, vol.32, issue.10, pp.653-658, 2013.
DOI : 10.1016/j.annfar.2013.07.802

E. Cavus, Effects of cerebral hypoperfusion on bispectral index: A randomised, controlled animal experiment during haemorrhagic shock, Resuscitation, vol.81, issue.9, pp.1183-1189, 2010.
DOI : 10.1016/j.resuscitation.2010.05.018

G. Besch, Occurrence of and risk factors for electroencephalogram burst suppression during propofol-remifentanil anaesthesia, British Journal of Anaesthesia, vol.107, issue.5, pp.749-756, 2011.
DOI : 10.1093/bja/aer235

URL : https://hal.archives-ouvertes.fr/hal-00687540

M. Willingham, Association between intraoperative electroencephalographic suppression and postoperative mortality, British Journal of Anaesthesia, vol.113, issue.6, pp.1001-1008, 2014.
DOI : 10.1093/bja/aeu105

URL : https://academic.oup.com/bja/article-pdf/113/6/1001/692557/aeu105.pdf