Accuracy and dynamic response of disposable pressure transducertubing systems, Canadian Journal of Anaesthesia, vol.12, issue.4, pp.409-423, 1987. ,
DOI : 10.1007/BF03010146
Quantification and simulation of fluid-filled catheter/transducer systems, Med Instrum, vol.20, issue.3, pp.123-132, 1986. ,
Accuracy of invasive arterial pressure monitoring in cardiovascular patients: an observational study, Critical Care, vol.39, issue.6, p.644, 2014. ,
DOI : 10.1007/s00134-013-2861-8
Direct Blood Pressure Measurement ???Dynamic Response Requirements, Anesthesiology, vol.54, issue.3, pp.227-263, 1981. ,
DOI : 10.1097/00000542-198103000-00010
A Simple Non-physiological Artifact Filter for Invasive Arterial Blood Pressure Monitoring: a Study of 1852 Trauma ICU Patients, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society, pp.1417-1437, 2006. ,
DOI : 10.1109/IEMBS.2006.260684
Time-dependent Pressure Distortion in a Catheter???Transducer System, Anesthesiology, vol.92, issue.1, pp.208-226, 2000. ,
DOI : 10.1097/00000542-200001000-00033
Arterial Waveform Analysis for the Anesthesiologist, Anesthesia & Analgesia, vol.113, issue.4, 2001. ,
DOI : 10.1213/ANE.0b013e31822773ec
The dynamic responses of liquid-filled catheter systems for direct measurements of blood pressure, Anesthesiology, vol.53, issue.6, 1980. ,
The Fast Flush Test Measures the Dynamic Response of the Entire Blood Pressure Monitoring System, Anesthesiology, vol.77, issue.6, pp.1215-1235, 1992. ,
DOI : 10.1097/00000542-199212000-00024
Minimally Invasive Cardiac Output Monitoring in the Perioperative Setting, Anesthesia & Analgesia, vol.108, issue.3, pp.887-97, 2009. ,
DOI : 10.1213/ane.0b013e31818ffd99
Cardiac Output Determination From the Arterial Pressure Wave: Clinical Testing of a Novel Algorithm That Does Not Require Calibration, Journal of Cardiothoracic and Vascular Anesthesia, vol.21, issue.1, 2007. ,
DOI : 10.1053/j.jvca.2006.08.004
A pilot assessment of the FloTrac cardiac output monitoring system comparing with pulmonary artery catheter method by three versions, Masui, vol.58, issue.11, pp.1418-1441, 2009. ,
Intensive care unit alarms???How many do we need?*, Critical Care Medicine, vol.38, issue.2, pp.451-457, 2010. ,
DOI : 10.1097/CCM.0b013e3181cb0888
Hemodynamic parameters to guide fluid 39 therapy, Ann Intensive Care, vol.1, issue.1, 2011. ,
Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature*, Critical Care Medicine, vol.37, issue.9, pp.2642-2649, 2009. ,
DOI : 10.1097/CCM.0b013e3181a590da
The ability of PiCCO versus LiDCO variables to detect changes in cardiac index: a prospective clinical study, Minerva Anestesiol, vol.74, pp.7-8367, 2008. ,
The Pressure Recording Analytical Method (PRAM): Technical Concepts and Literature Review, Journal of Cardiothoracic and Vascular Anesthesia, vol.31, issue.4, 2016. ,
DOI : 10.1053/j.jvca.2016.09.004
Reliability of cardiac output measurements using LiDCOrapid??? and FloTrac/Vigileo??? across broad ranges of cardiac output values, Journal of Clinical Monitoring and Computing, vol.29, issue.1, 2016. ,
DOI : 10.1007/s10877-014-9619-x
Respiratory variation of systolic and diastolic time intervals within radial arterial waveform: a comparison with dynamic preload index, Journal of Clinical Anesthesia, vol.32, pp.75-81 ,
DOI : 10.1016/j.jclinane.2015.12.022
Effect of stroke volume variation-directed fluid management on blood loss during living-donor right hepatectomy: a randomised controlled study, Anaesthesia, vol.39, issue.11, 2015. ,
DOI : 10.1007/s00595-008-3917-1
An application of arterial pressure-based cardiac output measurements in fluid management strategies of critically ill patients, 2014. ,
Dynamic response of liquid-filled catheter systems for measurement of blood pressure: precision of measurements and reliability of the Pressure Recording Analytical Method with different disposable systems, Journal of Critical Care, vol.26, issue.4, 2011. ,
DOI : 10.1016/j.jcrc.2010.08.010
Performance of a minimally invasive uncalibrated cardiac output monitoring system (Flotrac???/Vigileo???) in haemodynamically unstable patients ???, British Journal of Anaesthesia, vol.100, issue.4, 2008. ,
DOI : 10.1093/bja/aem409
Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients, British Journal of Anaesthesia, vol.108, issue.4, pp.615-637 ,
DOI : 10.1093/bja/aer491
Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients, Intensive Care Medicine, vol.21, issue.2, pp.233-273, 2011. ,
DOI : 10.1007/s10877-007-9093-9