H. Schilder, Cleaning and shaping the root canal, Dent Clin North Am. avr, vol.18, issue.2, pp.269-96, 1974.

L. Lupi-pegurier, M. Bertrand, M. Muller-bolla, J. Rocca, and M. Bolla, Periapical status, prevalence and quality of endodontic treatment in an adult French population, International Endodontic Journal, vol.13, issue.8, pp.690-697, 2002.
DOI : 10.1111/j.1600-9657.1997.tb00013.x

Y. Boucher, L. Matossian, F. Rilliard, and P. Machtou, Radiographic evaluation of the prevalence and technical quality of root canal treatment in a French subpopulation, International Endodontic Journal, vol.4, issue.3, pp.229-267, 2002.
DOI : 10.1111/j.1600-9657.1997.tb00013.x

P. Tavares, E. Bonte, T. Boukpessi, J. Siqueira, and J. Lasfargues, Prevalence of Apical Periodontitis in Root Canal???Treated Teeth From an Urban French Population: Influence of the Quality of Root Canal Fillings and Coronal Restorations, Journal of Endodontics, vol.35, issue.6, pp.810-813, 2009.
DOI : 10.1016/j.joen.2009.03.048

H. Traitement-endodontique, Rapport d'évaluation technologique Disponible sur: http://www.has-sante, 2008.

H. Kim, S. Kwak, G. Cheung, D. Ko, S. Chung et al., Cyclic Fatigue and Torsional Resistance of Two New Nickel-Titanium Instruments Used in Reciprocation Motion: Reciproc Versus WaveOne, Journal of Endodontics, vol.38, issue.4, pp.541-545, 2012.
DOI : 10.1016/j.joen.2011.11.014

H. Walia, W. Brantley, and H. Gerstein, An initial investigation of the bending and torsional properties of nitinol root canal files, Journal of Endodontics, vol.14, issue.7, pp.346-51, 1988.
DOI : 10.1016/S0099-2399(88)80196-1

G. Yared, Canal preparation using only one Ni-Ti rotary instrument: preliminary observations, International Endodontic Journal, vol.18, issue.4, pp.339-383, 2008.
DOI : 10.1016/S0099-2399(88)80137-7

G. De-deus, E. Moreira, H. Lopes, and C. Elias, Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement, International Endodontic Journal, vol.28, issue.12, pp.1063-1071, 2010.
DOI : 10.1111/j.1365-2591.2010.01756.x

P. Parashos and H. Messer, Rotary NiTi Instrument Fracture and its Consequences, Journal of Endodontics, vol.32, issue.11, pp.1031-1074, 2006.
DOI : 10.1016/j.joen.2006.06.008

G. Gavini, C. Caldeira, E. Akisue, C. Gt-de, M. Kawakami et al., Resistance to Flexural Fatigue of Reciproc R25 Files under Continuous Rotation and Reciprocating Movement, Journal of Endodontics, vol.38, issue.5, pp.684-691, 2012.
DOI : 10.1016/j.joen.2011.12.033

B. Sattapan, G. Nervo, J. Palamara, and H. Messer, Defects in Rotary Nickel-Titanium Files After Clinical Use, Journal of Endodontics, vol.26, issue.3, pp.161-165, 2000.
DOI : 10.1097/00004770-200003000-00008

W. Pertot, L. Pommel, S. Simon, and P. Machtou, Mise en forme et nettoyage du système canalaire.Chapitre10, CDP; 2012. p. 187?217. (JPIO)

B. Martín, G. Zelada, P. Varela, J. Bahillo, F. Magán et al., Factors influencing the fracture of nickel-titanium rotary instruments, International Endodontic Journal, vol.23, issue.4, pp.262-268, 2003.
DOI : 10.1046/j.1365-2591.1999.00201.x

M. Bahia, V. Buono, M. Dickson, J. Aitken, and J. Bagg, Decrease in the fatigue resistance of nickel-titanium rotary instruments after clinical use in curved root canals Oral Surg Oral Med Oral Pathol Oral Radiol Endodontology Contaminated dental instruments, 249?55. 16. Smith A, pp.233-238, 2002.

D. Sonntag and O. Peters, Effect of Prion Decontamination Protocols on Nickel-Titanium Rotary Surfaces, Journal of Endodontics, vol.33, issue.4, pp.442-448, 2007.
DOI : 10.1016/j.joen.2006.12.012

Y. Shen, A. Riyahi, L. Campbell, H. Zhou, T. Du et al., Effect of a Combination of Torsional and Cyclic Fatigue Preloading on the Fracture Behavior of K3 and K3XF Instruments, Journal of Endodontics, vol.41, issue.4, pp.526-556, 2015.
DOI : 10.1016/j.joen.2014.10.008

I. Benkiran, K. Lahlou, M. Jabri, E. Ouazzani, A. Hireche et al., Introduction du Nickel- Titane en endodontie | Dossiers du mois Courr Dent Portail Form Dent Contin Francoph, Disponible sur, 1999.

D. Martin, J. Amor, and P. Machtou, Mechanized endodontics: the protaper ® system. Principes and clinical protocol, Rev Odontostomatol-PARIS, vol.31, issue.1, pp.33-44, 2002.

S. Simon, P. Machtou, P. Tomson, N. Adams, and P. Lumley, Influence of Fractured Instruments on the Success Rate of Endodontic Treatment, Dental Update, vol.35, issue.3, p.172, 2008.
DOI : 10.12968/denu.2008.35.3.172

M. Mcguigan, C. Louca, and H. Duncan, Clinical decision-making after endodontic instrument fracture, 395?400. 23. Code de la santé publique -Article L1111-2. Code de la santé publique, 2013.
DOI : 10.1016/S0099-2399(06)80062-2

D. Fiore and P. , A dozen ways to prevent nickel-titanium rotary instrument fracture, The Journal of the American Dental Association, vol.138, issue.2, pp.196-201, 1939.
DOI : 10.14219/jada.archive.2007.0136

A. Eble, Pr??venir et traiter la fracture des instruments endodontiques en NiTi (Nickel-Titane), Actualit??s Odonto-Stomatologiques, vol.28, issue.7, pp.151-60, 2012.
DOI : 10.1097/00004770-200207000-00014

URL : https://aos.edp-dentaire.fr/articles/aos/pdf/2012/02/aos2012258p151.pdf

J. Peli, Bases fondamentales de la préparation en Rotation Continue [Internet]. Dentisfuturis Disponible sur: https://www.dentisfuturis.com/bases- fondamentales-de-la-prparation-en-rotation-continue, 1999.

F. Marshall and J. Pappin, A crown-down pressureless preparation root canal enlargement technique, Tech Man Portland, 1980.

C. Ruddle, Endodontic canal preparation: breakthrough cleaning and shaping strategies, Dent Today. févr, vol.13, issue.46, pp.44-48, 1994.

. Mtwo, The efficient NiTi system Disponible sur: http://www.vdwdental.com/fileadmin/redaktion/downloads/produkte/en/en- mtwo_anwender_rev11.pdf 30. Viteaux A. L'instrumentation unique en rotation continue | Dental Tribune International

G. Gastaldo, R. Beltrami, M. Chiesa, and C. Poggio, F360 and F6 Skytaper: SEM evaluation of cleaning efficiency, Ann Stomatol, vol.6, issue.3?4, p.69, 2015.

M. Gundogar and T. Ozyurek, Cyclic Fatigue Resistance of OneShape, HyFlex EDM, WaveOne Gold, and Reciproc Blue Nickel-titanium Instruments, Journal of Endodontics, vol.43, issue.7, pp.1192-1198, 2017.
DOI : 10.1016/j.joen.2017.03.009

N. Grande, H. Ahmed, S. Cohen, F. Bukiet, and G. Plotino, Current Assessment of Reciprocation in Endodontic Preparation: A Comprehensive Review???Part I: Historic Perspectives and Current Applications, Journal of Endodontics, vol.41, issue.11, pp.1778-83, 2015.
DOI : 10.1016/j.joen.2015.06.014

-. Wilhelm and . Pertot, Mise en forme canalaire monoinstrumentale en mouvement réciproque

C. Keskin, U. Inan, and M. Demiral, Effect of interrupted motion on the cyclic fatigue resistance of reciprocating nickel-titanium instruments, International Endodontic Journal, vol.38, issue.5, 2017.
DOI : 10.1016/S0020-7683(00)00283-3

C. Keskin, U. Inan, M. Demiral, and A. Keles, Cyclic Fatigue Resistance of Reciproc Blue, Reciproc, and WaveOne Gold Reciprocating Instruments, Journal of Endodontics, vol.43, issue.8, 2017.
DOI : 10.1016/j.joen.2017.03.036

G. De-deus, E. Silva, V. Vieira, F. Belladonna, C. Elias et al., Blue Thermomechanical Treatment Optimizes Fatigue Resistance and Flexibility of the Reciproc Files, Journal of Endodontics, vol.43, issue.3, pp.462-468, 2017.
DOI : 10.1016/j.joen.2016.10.039

G. Deus, Bending Resistance and Cyclic Fatigue Life of Reciproc, Unicone, and WaveOne Reciprocating Instruments Twisted Files and Adaptive Motion Technology: A Winning Combination for Safe and Predictable Root Canal Shaping - Oral Health Group, 1789?93. IV 40. Gary Glassman, 2016.

S. Elsaka, A. Elnaghy, and A. Badr, Torsional and bending resistance of WaveOne Gold, Reciproc and Twisted File Adaptive instruments, International Endodontic Journal, vol.36, issue.11, pp.1077-83, 2017.
DOI : 10.1016/j.joen.2010.04.017

A. Arias, J. Perez-higueras, and J. De-la-macorra, Differences in Cyclic Fatigue Resistance at Apical and Coronal Levels of Reciproc and WaveOne New Files, Journal of Endodontics, vol.38, issue.9, pp.1244-1252, 2012.
DOI : 10.1016/j.joen.2012.05.022

G. Plotino, N. Grande, L. Testarelli, and G. Gambarini, Cyclic fatigue of Reciproc and WaveOne reciprocating instruments, International Endodontic Journal, vol.37, issue.7, pp.614-622, 2012.
DOI : 10.1016/j.joen.2011.05.021

G. De-deus, L. Vieira, V. , N. Da-silva, E. Lopes et al., Bending Resistance and Dynamic and Static Cyclic Fatigue Life of Reciproc and WaveOne Large Instruments, Journal of Endodontics, vol.40, issue.4, pp.575-584, 2014.
DOI : 10.1016/j.joen.2013.10.013

N. Varghese, R. Pillai, U. Sujathen, S. Sainudeen, A. A. Paul et al., Resistance to torsional failure and cyclic fatigue resistance of ProTaper Next, WaveOne, and Mtwo files in continuous and reciprocating motion: An in vitro study, J Conserv Dent, vol.19, issue.3, p.225, 2016.

P. Scelza, D. Harry, L. Silva, . Da, I. Barbosa et al., A comparison of two reciprocating instruments using bending stress and cyclic fatigue tests, 1?7. 47. Elnaghy AM, Elsaka SE. Torsion and Bending Properties of OneShape and WaveOne Instruments, pp.544-551, 2015.
DOI : 10.1111/iej.12025

V. Llácer, In Vitro Comparison of Cyclic Fatigue Resistance of ProTaper, WaveOne, and Twisted Files, J Endod. nov, vol.38, issue.11, pp.1521-1525, 2012.

E. Pedullà, N. Grande, G. Plotino, G. Gambarini, E. F. Rapisarda et al., Influence of Continuous or Reciprocating Motion on Cyclic Fatigue Resistance of 4 Different Nickel-Titanium Rotary Instruments Comparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems, J Endod. févr J Oral Sci, vol.3956, issue.24, pp.269-75, 2013.

C. Poggio, R. Beltrami, M. Colombo, M. Chiesa, S. Bianchi et al., Cyclic fatigue resistance of OneShape, Reciproc, and WaveOne: An in vitro comparative study, Journal of Conservative Dentistry, vol.17, issue.3, p.250, 2014.
DOI : 10.4103/0972-0707.131788

O. Higuera, G. Plotino, L. Tocci, G. Carrillo, G. Gambarini et al., Cyclic Fatigue Resistance of 3 Different Nickel-Titanium Reciprocating Instruments in Artificial Canals, Journal of Endodontics, vol.41, issue.6, pp.913-918, 2015.
DOI : 10.1016/j.joen.2015.01.023

V. Sekar, R. Kumar, S. Nandini, S. Ballal, and N. Velmurugan, Assessment of the role of cross section on fatigue resistance of rotary files when used in reciprocation, Eur J Dent, vol.10, issue.4, p.541, 2016.

E. Pedullà, N. Grande, G. Plotino, F. Palermo, G. Gambarini et al., Cyclic fatigue resistance of two reciprocating nickel-titanium instruments after immersion in sodium hypochlorite, International Endodontic Journal, vol.32, issue.2, pp.155-164, 2013.
DOI : 10.1016/j.joen.2005.09.014

J. Kim, J. Ha, G. Cheung, A. Versluis, S. Kwak et al., Safety of the Factory Preset Rotation Angle of Reciprocating Instruments, Journal of Endodontics, vol.40, issue.10, pp.1671-1676, 2014.
DOI : 10.1016/j.joen.2014.06.002

A. Elnaghy and S. Elsaka, Effect of sodium hypochlorite and saline on cyclic fatigue resistance of WaveOne Gold and Reciproc reciprocating instruments, International Endodontic Journal, vol.128, issue.10, 2016.
DOI : 10.1016/j.joen.2016.01.025

T. Özyürek, Cyclic Fatigue Resistance of Reciproc, WaveOne, and WaveOne Gold Nickel-Titanium Instruments, Journal of Endodontics, vol.42, issue.10, pp.1536-1545, 2016.
DOI : 10.1016/j.joen.2016.06.019

H. Topçuo?lu, S. Düzgün, A. Akt?, and G. Topçuo?lu, Laboratory comparison of cyclic fatigue resistance of WaveOne Gold, Reciproc and WaveOne files in canals with a double curvature, International Endodontic Journal, vol.30, issue.7, pp.713-720, 2017.
DOI : 10.1097/00004770-200406000-00008

S. Elsaka, A. Elnaghy, and A. Badr, Torsional and bending resistance of WaveOne Gold, Reciproc and Twisted File Adaptive instruments, International Endodontic Journal, vol.36, issue.11, pp.1077-83, 2017.
DOI : 10.1016/j.joen.2010.04.017

P. Varela-patiño, A. Ibañez-párraga, B. Rivas-mundiña, G. Cantatore, X. Otero et al., Alternating versus Continuous Rotation: A Comparative Study of the Effect on Instrument Life, Journal of Endodontics, vol.36, issue.1, pp.157-166, 2010.
DOI : 10.1016/j.joen.2009.09.023

R. Cunha, A. Junaid, P. Ensinas, W. Nudera, . Da-silveira et al., Assessment of the Separation Incidence of Reciprocating WaveOne Files: A Prospective Clinical Study, Journal of Endodontics, vol.40, issue.7
DOI : 10.1016/j.joen.2014.03.016

G. Plotino, N. Grande, and P. Porciani, Deformation and fracture incidence of Reciproc instruments: a clinical evaluation, International Endodontic Journal, vol.46, issue.2, pp.199-205, 2015.
DOI : 10.1111/iej.12085

M. Zuolo, M. Carvalho, and G. De-deus, Negotiability of Second Mesiobuccal Canals in Maxillary Molars Using a Reciprocating System, 1913?7. 65. Bueno CSP, 2015.
DOI : 10.1016/j.joen.2015.08.004

G. Plotino, G. Rubini, A. Grande, N. Testarelli, L. Gambarini et al., Cutting Efficiency of Reciproc and WaveOne Reciprocating Instruments, Journal of Endodontics, vol.40, issue.8, pp.1228-1258, 2014.
DOI : 10.1016/j.joen.2014.01.041

L. Generali, E. Righi, M. Todesca, and U. Consolo, Canal shaping with WaveOne reciprocating files: influence of operator experience on instrument breakage and canal preparation time, Odontology, vol.38, issue.2, pp.217-239, 2014.
DOI : 10.1016/j.joen.2011.12.040

E. Berutti, G. Chiandussi, D. Paolino, N. Scotti, G. Cantatore et al., Canal Shaping with WaveOne Primary Reciprocating Files and ProTaper System: A Comparative Study Cleanability of dental instruments ? implications of residual protein and risks from Creutzfeldt-Jakob disease, 505?9. 69, pp.395-401, 2007.

J. Popovic, J. Gasic, S. Zivkovic, A. Petrovic, and G. Radicevic, Evaluation of biological debris on endodontic instruments after cleaning and sterilization procedures, International Endodontic Journal, vol.203, issue.4, pp.336-377, 2010.
DOI : 10.1099/0022-1317-80-11-3043