« Electrochemical behavior of titanium in artificial saliva: influence of pH ». The journal of oral implantology 40, 2014. ,
Metallic wear in failed titanium-alloy total hip replacements. A histological and quantitative analysis., The Journal of Bone & Joint Surgery, vol.70, issue.3, pp.347-56, 1988. ,
DOI : 10.2106/00004623-198870030-00005
Peri-implantitis " : a complication of a foreign body or a man-made " disease " . facts and fiction ». Clinical implant dentistry and related research 18, pp.840-889, 2016. ,
« Oral implant surfaces. Part 1, Review focusing on topographic and chemical properties of different surfaces and in vivo responses to them ». The international journal of prosthodontics 17, pp.536-579, 2004. ,
« Microstructure and morphology of surface oxide films on ti, Journal of materials research, vol.5, pp.6-7, 1990. ,
« A three-year follow-up report of a comparative study of iti dental implants and Brånemark system implants in the treatment of the partially edentulous maxilla ». Clinical implant dentistry and related research 6, pp.130-171, 2004. ,
Nickel and vanadium metal ions induce apoptosis of T-lymphocyte Jurkat cells, Journal of biomedical materials research Part A 79A, pp.512-533, 2006. ,
DOI : 10.1002/jbm.a.30811
to Corroded Commercially Pure Titanium and Titanium-Aluminum-Vanadium Alloy, Journal of Periodontology, vol.9, issue.9, pp.1275-82, 2014. ,
DOI : 10.1111/j.1600-0501.2007.01378.x
Selective accumulation of aluminum in cerebral arteries in Alzheimer's disease (AD), Journal of Inorganic Biochemistry, vol.126, pp.35-37, 2013. ,
DOI : 10.1016/j.jinorgbio.2013.05.007
URL : http://europepmc.org/articles/pmc3720708?pdf=render
Metal wear particles: What we know, what we do not know, and why, SAS Journal, vol.3, issue.4, pp.133-175, 2009. ,
DOI : 10.1016/j.esas.2009.11.006
Aluminum Neurotoxicity in Preterm Infants Receiving Intravenous-Feeding Solutions, New England Journal of Medicine, vol.336, issue.22, pp.22-1557, 1997. ,
DOI : 10.1056/NEJM199705293362203
« Vanadium et ses composés ». Institut national de l'environnement industriel et des risques, 2012. ,
Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions, Periodontology 2000, vol.14, issue.Suppl 1, pp.22-40, 2000. ,
DOI : 10.1034/j.1600-0501.2003.140203.x
Peri-implant Inflammation Defined by the Implant-Abutment Interface, Journal of Dental Research, vol.85, issue.5, pp.473-78, 2006. ,
DOI : 10.1902/jop.1992.63.12.995
Effects of Neck Extension, Coverage, and Frequency on The Fretting Corrosion Of Modular THR Bore and Cone Interface, Modularity of orthopedic implants, 189-189? 10. West Conshohocken: American society for testing and materials, 1997. ,
DOI : 10.1520/STP12032S
Effect of mechanical surface pretreatment on metal ion release, Biomaterials, vol.21, issue.4, pp.385-92, 2000. ,
DOI : 10.1016/S0142-9612(99)00200-8
Metal release from dental biomaterials, Biomaterials, vol.7, issue.3, pp.163-750142, 1986. ,
DOI : 10.1016/0142-9612(86)90097-9
« In vitro evaluation of cytotoxicity and corrosion behavior of commercially pure titanium and ti-6al-4v alloy for dental implants », Journal of indian prosthodontic society, vol.17, issue.1, pp.35-400972, 2017. ,
Aluminum and bone: review of new clinical circumstances associated with al(3+) deposition in the calcified matrix of bone ». Morphologie: bulletin de l'association des anatomistes 100, 95? 105, p.329, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01392262
« An overview of the corrosion aspect of dental implants (titanium and its alloys) ». Indian journal of dental research 20, pp.91-98, 2009. ,
DOI : 10.4103/0970-9290.49068
URL : https://doi.org/10.4103/0970-9290.49068
« Is there scientific evidence favoring the substitution of commercially pure titanium with titanium alloys for the manufacture of dental implants ? » Materials science & engineering C 71 (2017): 1201? 15 ,
« Vanadium : a review of the reproductive and developmental toxicity ». Reproductive toxicology 10, pp.175-820890, 1996. ,
DOI : 10.1016/0890-6238(96)00019-6
Short-term toxicity studies of vanadium in rats, Journal of Applied Toxicology, vol.9, issue.6, pp.418-439, 1985. ,
DOI : 10.1042/bj0350837
Characterization of the fretting corrosion behavior, surface and debris from head-taper interface of two different modular hip prostheses, Journal of the Mechanical Behavior of Biomedical Materials, vol.62, pp.71-82, 2016. ,
DOI : 10.1016/j.jmbbm.2016.04.036
Salivary metal levels of orthodontic patients: a novel methodological and analytical approach ». The european journal of orthodontics 25, pp.103-109, 2003. ,
DOI : 10.1093/ejo/25.1.103
URL : https://academic.oup.com/ejo/article-pdf/25/1/103/1302728/250103.pdf
Oral Vanadyl Sulphate Does not Affect Blood Cells, Viscosity or Biochemistry in Humans, Pharmacology & Toxicology, vol.6, issue.Suppl. 7, pp.202-208, 1997. ,
DOI : 10.1123/ijsn.6.4.382
URL : http://onlinelibrary.wiley.com/doi/10.1111/j.1600-0773.1997.tb00397.x/pdf
Why do some titanium-alloy total hip arthroplasty modular necks fail?, Journal of the Mechanical Behavior of Biomedical Materials, vol.69, pp.107-121, 2017. ,
DOI : 10.1016/j.jmbbm.2016.12.012
Site-specific adhesion of Staphylococcus epidermidis (RP12) in Ti-Al-V metal systems, Biomaterials, vol.15, issue.8, pp.628-662, 1994. ,
DOI : 10.1016/0142-9612(94)90214-3
In vivo oxide-induced stress corrosion cracking of Ti-6Al-4V in a neck-stem modular taper: Emergent behavior in a new mechanism of in vivo corrosion, Journal of Biomedical Materials Research Part B: Applied Biomaterials, vol.93, issue.2, pp.584-94, 2012. ,
DOI : 10.1002/jbm.b.31171
« Titanium orthodontic brackets : structure, composition, hardness and ionic release ». Dental materials 20, pp.693-700, 2004. ,
Electrochemically induced anatase inhibits bacterial colonization on Titanium Grade 2 and Ti6Al4V alloy for dental and orthopedic devices, Colloids and Surfaces B: Biointerfaces, vol.88, issue.2, pp.648-55, 2011. ,
DOI : 10.1016/j.colsurfb.2011.07.054
« Serum metal ions with a titanium modular neck total hip replacement system ». The journal of arthroplasty 30, pp.1781-86, 2015. ,
DOI : 10.1016/j.arth.2015.04.040
Influence of fluoride content and pH on corrosion and tribocorrosion behaviour of Ti13Nb13Zr alloy in oral environment, Journal of the Mechanical Behavior of Biomedical Materials, vol.49, pp.186-96, 2015. ,
DOI : 10.1016/j.jmbbm.2015.05.008
« Measurement and evaluation of galvanic corrosion between titanium/ti6a14v implants and dental alloys by electrochemical techniques and auger spectrometry », Biomaterials, vol.20, pp.10-933, 1999. ,
DOI : 10.1016/s0142-9612(98)00248-8
A review of the biologic effects of spine implant debris: Fact from fiction, SAS Journal, vol.3, issue.4, pp.143-60, 2009. ,
DOI : 10.1016/j.esas.2009.11.005
Quantitative and qualitative investigations of surface enlarged titanium and titanium alloy implants, Clinical Oral Implants Research, vol.9, issue.1, pp.1-10, 1998. ,
DOI : 10.1034/j.1600-0501.1998.090101.x
Metal ion release from metal implants » Materials science and engineering: c 24, pp.745-52, 2004. ,
DOI : 10.1016/j.msec.2004.08.018
« Aluminium et vaccins, rapport », 2013 ,
Metal Release in Patients Who Have Had a Primary Total Hip Arthroplasty. A Prospective, Controlled, Longitudinal Study*, The Journal of Bone & Joint Surgery, vol.80, issue.10, pp.10-1447, 1998. ,
DOI : 10.2106/00004623-199810000-00006
« A quantitative comparison of machined commercially pure titanium and titanium-aluminum-vanadium implants in rabbit bone ». The international journal of oral & maxillofacial implants 13, pp.315-336, 1998. ,
Ultrastructural differences of the interface zone between bone and Ti 6Al 4V or commercially pure titanium, Journal of Biomedical Engineering, vol.11, issue.1, pp.3-8, 1989. ,
DOI : 10.1016/0141-5425(89)90158-1
« Link between aluminum and the pathogenesis of Alzheimer's disease : the integration of the aluminum and amyloid cascade hypotheses ». International journal of Alzheimer's disease 2011, p.276393, 2011. ,
Retrospective Clinical Study of Marginal Bone Level Changes with Two Different Screw-Implant Types: Comparison Between Tissue Level (TE) and Bone Level (BL) Implant, Journal of Maxillofacial and Oral Surgery, vol.4, issue.Suppl 1, pp.259-66, 2014. ,
DOI : 10.1034/j.1600-0501.1993.040307.x
URL : http://europepmc.org/articles/pmc4082557?pdf=render
« Electrochemical corrosion of titanium and titanium-based alloys ». The journal of prosthetic dentistry 85, pp.195-202, 2001. ,
« Aluminum induces osteoblast apoptosis through the oxidative stress-mediated jnk signaling pathway ». Biological trace element research 150, pp.12011-12023, 2012. ,
DOI : 10.1007/s12011-012-9523-5
Influence of the fabrication process and fluoride content on the tribocorrosion behaviour of Ti6Al4V biomedical alloy in artificial saliva, Journal of the Mechanical Behavior of Biomedical Materials, vol.20, pp.137-185, 2013. ,
DOI : 10.1016/j.jmbbm.2013.01.019
ASTM-F86 passivation increases trace element release from Ti6AI4V into culture medium, Journal of Materials Science: Materials in Medicine, vol.9, issue.A1, pp.467-72, 1994. ,
DOI : 10.1007/BF00058985
Comparative corrosion study of Ti???Ta alloys for dental applications, Acta Biomaterialia, vol.5, issue.9, pp.3625-3664, 2009. ,
DOI : 10.1016/j.actbio.2009.05.037
URL : https://hal.archives-ouvertes.fr/hal-00761551
Influence of pH on the tribocorrosion behavior of CpTi in the oral environment: synergistic interactions of wear and corrosion, Journal of Biomedical Materials Research Part B: Applied Biomaterials, vol.90, issue.6, pp.1662-71, 2012. ,
DOI : 10.1177/0022034510396880
What is the role of lipopolysaccharide on the tribocorrosive behavior of titanium?, Journal of the Mechanical Behavior of Biomedical Materials, vol.8, pp.71-85, 2012. ,
DOI : 10.1016/j.jmbbm.2011.11.004
« Tribocorrosion and oral and maxillofacial surgical devices ». The british journal of oral & maxillofacial surgery 52, pp.396-400, 2014. ,
DOI : 10.1016/j.bjoms.2014.02.010
Discrete calcium phosphate nanocrystalline deposition enhances osteoconduction on titanium-based implant surfaces, Journal of Biomedical Materials Research Part A, vol.27, issue.2, pp.577-85, 2009. ,
DOI : 10.1177/00220345860650080501
« The effect of fluoride ions on the corrosion behaviour of ti metal, and ti6-al-7nb and ti-6al-4v alloys in artificial saliva », Acta chimica slovenica, vol.60, issue.3, pp.543-55, 2013. ,
The epidemiology of peri-implantitis, Clinical Oral Implants Research, vol.28, issue.Suppl 2, pp.67-76, 2012. ,
DOI : 10.1034/j.1600-051x.2001.028006517.x
Titanium alloy mini-implants for orthodontic anchorage: Immediate loading and metal ion release???, Acta Biomaterialia, vol.3, issue.3, pp.331-370, 2007. ,
DOI : 10.1016/j.actbio.2006.10.010
état de surface du titane et de ses alliages en implantologie : comparaison des implants dentaires de marques différentes, Thèse d'exercice, 2012. ,
« Can degradation products released from dental implants affect peri-implant tissues ?, Journal of periodontal research, 2017. ,
Biomaterial and antibiotic strategies for peri-implantitis: A review, Journal of Biomedical Materials Research Part B: Applied Biomaterials, vol.42, issue.(Part 2), pp.530-573, 2009. ,
DOI : 10.1002/jbm.a.30789
URL : http://onlinelibrary.wiley.com/doi/10.1002/jbm.b.31152/pdf
Comparison of metal release from various metallic biomaterials in vitro, Biomaterials, vol.26, issue.1, pp.11-21, 2005. ,
DOI : 10.1016/j.biomaterials.2004.02.005
Morphological studies on machined implants of commercially pure titanium and titanium alloy (Ti6Al4V) in the rabbit, Journal of Biomedical Materials Research Part B: Applied Biomaterials, vol.79, issue.Pt 1, pp.309-328, 2009. ,
DOI : 10.1177/00220345920710020401
« Early functional loading of unsplinted roughened surface implants with mandibular overdentures 2 weeks after surgery ». Clinical implant dentistry and related research 5, pp.143-53, 2003. ,
DOI : 10.1111/j.1708-8208.2003.tb00196.x
Neurotoxic Effects of Aluminium Among Foundry Workers and Alzheimer???s Disease, NeuroToxicology, vol.23, issue.6, pp.761-74, 2002. ,
DOI : 10.1016/S0161-813X(02)00097-9
Effects of fluorides on titanium and other dental alloys in dentistry, Biomaterials, vol.19, issue.1-3, pp.1-3, 1998. ,
DOI : 10.1016/S0142-9612(97)00179-8
Rutger Persson. « Infection at titanium implants with or without a clinical diagnosis of inflammation ». Clinical oral implants research 18, pp.509-525, 2007. ,
Vanadium distribution in rats and DNA cleavage by vanadyl complex: implication for vanadium toxicity and biological effects, Environmental Health Perspectives, vol.102, issue.Suppl 3, pp.35-36, 1994. ,
DOI : 10.1289/ehp.94102s335
URL : http://europepmc.org/articles/pmc1567403?pdf=render
Bone apposition to a titanium-zirconium alloy implant, as compared to two other titanium-containing implants, European Cells and Materials, vol.23, pp.273-286, 2012. ,
DOI : 10.22203/eCM.v023a21
URL : http://doi.org/10.22203/ecm.v023a21
Bacterial Adherence to Tantalum Versus Commonly Used Orthopedic Metallic Implant Materials, Journal of Orthopaedic Trauma, vol.20, issue.7, pp.476-84, 2006. ,
DOI : 10.1097/00005131-200608000-00005
Aluminum hydroxide injections lead to motor deficits and motor neuron degeneration, Journal of Inorganic Biochemistry, vol.103, issue.11, pp.1555-62, 2009. ,
DOI : 10.1016/j.jinorgbio.2009.05.019
URL : http://europepmc.org/articles/pmc2819810?pdf=render
« Adherence ability of Staphylococcus epidermidis on prosthetic biomaterials : an in vitro study, International journal of nanomedicine, vol.8, pp.3955-61, 2013. ,
« The effect of oral topical fluorides on the surface of commercially pure titanium ». The international journal of oral & maxillofacial implants 6, pp.50-54, 1991. ,
Effect of vanadium on serum cholesterol, American Heart Journal, vol.64, issue.1, pp.54-56, 1962. ,
DOI : 10.1016/0002-8703(62)90091-1
Do oral biofilms influence the wear and corrosion behavior of titanium?, Biofouling, vol.86, issue.4, pp.471-78, 2010. ,
DOI : 10.1016/j.wear.2005.01.037
Effects of pH on the electrochemical behaviour of titanium alloys for implant applications, Journal of Materials Science: Materials in Medicine, vol.20, issue.2, pp.549-52, 2009. ,
DOI : 10.1007/s10856-008-3623-y
Etude du comportement viscoplastique en traction et en fluage de l'alliage TA6V de 20 à 600 degrés celsius, Thèse de doctorat : Science et Génie des matériaux, 2013. ,
Materials Science, Journal of Dental Research, vol.601, issue.5, pp.842-889, 1985. ,
DOI : 10.5006/0010-9312-29.1.18
« One-stage operative procedure using two different implant systems : a prospective study on implant overdentures in the edentulous mandible ». Clinical implant dentistry and related research 3, pp.185-93, 2001. ,
DOI : 10.1111/j.1708-8208.2001.tb00140.x
Effects of sublethal metal ion concentrations on osteogenic cells derived from bone marrow stromal cells, Journal of Applied Biomaterials, vol.28, issue.4, pp.249-58, 1995. ,
DOI : 10.1002/jab.770060406
The effects of low dose aluminum on hemorheological and hematological parameters in rats, Archives of Toxicology, vol.105, issue.1, pp.11-17, 2007. ,
DOI : 10.1016/0300-9629(93)90175-4
Initial versus subsequent release of elements from dental casting alloys, Journal of Oral Rehabilitation, vol.26, issue.10, pp.798-803, 1999. ,
DOI : 10.1046/j.1365-2842.1999.00455.x
« Bone level change at implantsupported fixed partial dentures with and without cantilever extension after 5 years in function », Journal of clinical periodontology, vol.31, issue.83, p.12, 2004. ,
Entry, Half-Life, and Desferrioxamine-Accelerated Clearance of Brain Aluminum after a Single 26Al Exposure, Toxicological Sciences, vol.47, issue.1-3, pp.77-82, 2001. ,
DOI : 10.1007/BF02790122
URL : https://academic.oup.com/toxsci/article-pdf/64/1/77/10891739/77.pdf
Aluminum citrate uptake by immortalized brain endothelial cells: implications for its blood???brain barrier transport, Brain Research, vol.930, issue.1-2, pp.1-2, 2002. ,
DOI : 10.1016/S0006-8993(02)02234-5
« Haematological results of vanadium intoxication in wistar rats ». Comparative biochemistry and physiology. C, Comparative pharmacology and toxicology 101, pp.57-61, 1992. ,
DOI : 10.1016/0742-8413(92)90199-h
Activation of monoamine oxidase type-B by aluminum in rat brain homogenate, NeuroReport, vol.10, issue.17, pp.17-3645, 1999. ,
DOI : 10.1097/00001756-199911260-00033
« Corrosion-fatigue life of commercially pure titanium and ti-6al-4v alloys in different storage environments ». The journal of prosthetic dentistry 84, pp.274-79, 2000. ,
DOI : 10.1067/mpr.2000.108758
Cellular responses of osteoblast-like cells to 17 elemental metals, Journal of Biomedical Materials Research Part A, vol.12, issue.1, pp.148-58, 2017. ,
DOI : 10.1023/A:1011237610299
URL : http://onlinelibrary.wiley.com/doi/10.1002/jbm.a.35895/pdf
Definition and prevalence of peri-implant diseases, Journal of Clinical Periodontology, vol.28, issue.(Suppl. 1), pp.286-91, 2008. ,
DOI : 10.1097/01.id.0000148564.88384.de
Vanadium carcinogenic, immunotoxic and neurotoxic effects : a review of in vitro studies ». Toxicology mechanisms and methods 24, pp.1-12, 2014. ,
DOI : 10.3109/15376516.2013.843110