G. Buchonnet, Hématopoïèse-Définition et méthodes d'exploration-cours DES Biologie médicale

A. Plonquet, Differenciation lymphocytaire B normale. REVUE FRANCOPHONE DES LABORATOIRES-MAI 2013-N°452

C. G. Vinuesa, S. G. Tangye, B. Moser, and C. R. Mackay, follicular B helper T cells in antibody responses and autoimmunity, Nature reviews | immunology, vol.5, 2005.

, Counting of highly fluorescent lymphocytes (HFLC) as antibodyproducing plasma cells on XE-5000. Sysmex Xtra Online, 2011.

J. Linssen, V. Jennissen, J. Hildmann, E. Reisinger, J. Schindler et al., Wielckens-Identification and Quantification of High Fluorescence-Stained Lymphocytes as Antibody Synthesizing/Secreting Cells Using the Automated Routine Hematology Analyzer XE-2100, Cytometry Part B (Clinical Cytometry), vol.72, pp.157-166, 2007.

, Lymphocyte differentiation update-helpful or dispensable, Sysmex educational enhancement and development, 2016.

A. Steiger, R. Fried, and . Lymphocytes, , pp.2014-2017

, Laboratoire d'Hématologie-CHU d'Angers. les cellules du sang normal

F. Valensi, Morphologie des cellules sanguines normales, EMC-Hématologie, vol.2, pp.1-13, 2005.

L. Baseggioa and P. Felman, Diagnostic des lymphocytoses hors LLC-typique. Hématologie : Hémopathies lymphoïdes b matures. Revue francophone des laboratoires-mai, 2013452.

, Laboratoire d'Hématologie-CHU d'Angers. Syndromes mononucléosiques

. Laboratoire-d'hématologie-chu-d'angers, Plasmocytes, morphologie et synthèse des immunoglobulines

. Laboratoire-d'hématologie-chu-d'angers, Lymphocytes activés et syndromes mononucléosiques

N. Valin, Conduite à tenir devant un syndrome mononucléosique. EMC-Maladies infectieuses 1 Volume 11 > n?2 > mai, 2014.

. Laboratoire-d'hématologie-chu-d, Angers. Observation, vol.46

J. F. Lesesve and . Troussard, Apoptotic Cells in a Peripheral Blood Smear in the Context of EBV Infection, American Journal of Hematology, vol.67, pp.147-149, 2001.

V. T. Nguyena, P. Vanclesb, L. Rozena, D. Noubouossiea, and A. Demulder, Évaluation de l'automate d'hématologie Sysmex XN-2000® pour une utilisation en routine : comparaison avec l'Advia 2120i®. Immuno-analyse et biologie spécialisée, vol.28, pp.125-132, 2013.

F. Geneviève, A. C. Galoisy, D. Mercier-bataille, O. Wagner-ballon, O. Trimoreau et al., , vol.LVI, p.317, 2014.

J. Hornain, XN Alarmes CBC-DIFF-RET-PLT-F / Version-02 / Septembre, 2013.

. Sysmex-academy, . Micror, and . Macror, Sysmex academy. Le paramètre plaquettaire IPF

N. Sysmex-academy.-le-paramètre,

, Novel haematological parameters for rapidly monitoring the immune system response. Sysmex white paper Infection/inflammation, 2017.

. Sysmex-academy and H. Le-parametre,

J. M. Pekelharing, O. Hauss, R. De-jonge, J. Lokhoff, J. Sodikromo et al., Haematology reference intervals for established and novel parameters in healthy adults. Diagnostic Perspectives|Volume 1, 2010.

A. Oehadian, M. Michels, Q. D. Mast, D. Prihatni, M. Puspita et al., New parameters available on Sysmex XE-5000

, hematology analyzers contribute to differentiating dengue from leptospirosis and enteric fever, Int. Jnl. Lab. Hem, p.37, 2015.

G. J. Edwin-van-mirre, N. Vrielink, H. Tjon-a-tsoi, and . Hendriks, Wim de Kieviet and Edwin ten Boekel. Sensitivity and specificity of the high fluorescent lymphocyte count-gate on the Sysmex XE-5000 hematology analyzer for detection of peripheral plasma cells, Clin Chem Lab Med, vol.49, issue.4, 2011.

Y. L. Luo, P. G. Xu, S. G. Peng, J. P. Li, and M. H. Kuang, Value of percentage of highly fluorescent lymphocytic cells for rapidly assessing septicemia in tumor patients, Zhonghua Yi Xue Za Zhi, vol.25, issue.24, pp.1894-1900, 2013.

M. Gelle and S. Daliphard, Cytologie du quotidien : règles de vérification technique aux postes des formules (CN) et d'Hématologie (SJ). Réf GEDI n° 12738, 2018.

M. Gelle and G. Buchonnet, Cytologie du quotidien : règles de vérification technique au poste des numérations, Réf GEDI, p.1757, 2018.

M. Gelle and S. Daliphard, Cytologie du quotidien : revues de lames au microscope. Réf GEDI n° 1574, 2018.

, Proposition de gestion des résultats pour sil externes. Pour automates de la classe XN

L. Igout and G. Buchonnet, Cytologie du quotidien: Valeurs de référence et bornes de la validation biologique en Hématologie cytologique. Réf GEDI n° 4921, 2017.

W. Van-der-meer, W. Van-gelder, R. De-keijzer, and H. Willems, The divergent morphological classification of variant lymphocytes in bood smears, 2005.

F. Trimoreau, A. Galoisy, F. Geneviève, V. Bardet, E. Cornet et al., Harmonisation of full blood count reports, recommendations of the French-speaking cellular haematology group (GFHC), J Clin Pathol, 2016.

U. Hippocrate,

, Au moment d'être admis à exercer la médecine, je promets et je jure d'être fidèle aux lois de l'honneur et de la probité

, Mon premier souci sera de rétablir, de préserver ou de promouvoir la santé dans tous ses éléments, physiques et mentaux

, Je respecterai toutes les personnes, leur autonomie et leur volonté, sans aucune discrimination selon leur état ou leurs convictions

, J'interviendrai pour les protéger si elles sont affaiblies, vulnérables ou menacées dans leur intégrité ou leur dignité

, Même sous la contrainte, je ne ferai pas usage de mes connaissances contre les lois de l'humanité

, Je ne tromperai jamais leur confiance et n'exploiterai pas le pouvoir hérité des circonstances pour forcer les consciences

, Je donnerai mes soins à l'indigent et à quiconque me les demandera

, Je ne me laisserai pas influencer par la soif du gain ou la recherche de la gloire

, Admis dans l'intimité des personnes, je tairai les secrets qui me seront confiés

, Reçu à l'intérieur des maisons, je respecterai les secrets des foyers et ma conduite ne servira pas à corrompre les moeurs

, Je préserverai l'indépendance nécessaire à l'accomplissement de ma mission

, Je les entretiendrai et les perfectionnerai pour assurer au mieux les services qui me seront demandés. J'apporterai mon aide à mes confrères ainsi qu

, Que les hommes et mes confrères m'accordent leur estime si je suis fidèle à mes promesses ; que je sois déshonoré et méprisé si j'y manque