J. Dejou and T. Giraud, Biomatériaux de restauration en implantologie : quelques critères de choix » in Patrick Tavitian ; Prothèses supra-implantaires : données et conception actuelles, Slovénie, pp.47-51, 2017.

F. Butz, G. Heydecke, M. Okutan, and J. R. Strub, Survival rate, fracture strength and failure mode of ceramic implant abutments after chewing simulation, Journal of Oral Rehabilitation, vol.32, issue.11, pp.838-881, 2005.

S. Yu, B. Song, K. Cheon, J. Kim, Y. Kim et al., Clinical reliability of zirconium abutment in implant restorations in the English and Korean literature. Maxillofacial Plastic & Reconstructive Surgery. 10 sept, vol.40, pp.1-1, 2018.

, Effect of titanium and zirconia dental implant abutments on a cultivable polymicrobial saliva community. The Journal of Prosthetic Dentistry, vol.118, pp.481-488, 2017.

A. Dahiya, N. Z. Baba, M. T. Kattadiyil, C. J. Goodacre, and A. Mann, Comparison of the effects of cement removal from zirconia and titanium abutments: An in vitro study, J Prosthet Dent. 1 déc, 2018.

R. E. Jung, I. Sailer, C. Hämmerle, T. Attin, and P. Schmidlin, In Vitro Color Changes of Soft Tissues Caused by Restorative Materials, International Journal of Periodontics & Restorative Dentistry. juin, vol.27, issue.3, pp.250-257, 2007.

L. Sala, A. Bascones-martínez, and A. Carrillo-de-albornoz, Impact of abutment material on peri-implant soft tissue color. An in vitro study, Clin Oral Investig. sept, vol.21, issue.7, pp.2221-2254, 2017.

C. Wang, H. Huang, D. Lin, Y. Shen, L. Fuh et al., Comparisons of maximum deformation and failure forces at the implant-abutment interface of titanium implants between titanium-alloy and zirconia abutments with two levels of marginal bone loss, Biomed Eng Online. 20 mai, vol.12, p.45, 2013.

I. Moris, Y. Chen, A. Faria, R. F. Ribeiro, A. Fok et al., Fracture loads and failure modes of customized and non-customized zirconia abutments, Dental Materials. 1 août, vol.34, issue.8, pp.197-204, 2018.

K. Yadav, Intricate Assessment and Evaluation of Effect of Bruxism on Long-term Survival and Failure of Dental Implants: A Comparative Study. The journal of contemporary dental practice, vol.8, pp.670-674, 2016.

, Bruxism and dental implant treatment complications: a retrospective comparative study of 98 bruxer patients and a matched group. -Clin Oral Implants Res, vol.28, pp.11-19, 2017.

, Factors influencing the fracture of dental implants. -Clin Implant Dent Relat Res, vol.20, pp.58-67, 2018.

I. Sailer, T. Sailer, B. Stawarczyk, R. E. Jung, and C. Hämmerle, In Vitro Study of the Influence of the Type of Connection on the Fracture Load of Zirconia Abutments with Internal and External ImplantAbutment Connections, International Journal of Oral & Maxillofacial Implants. oct, vol.24, issue.5, pp.850-858, 2009.

A. Naveau, C. Rignon-bret, and C. Wulfman, Zirconia abutments in the anterior region: A systematic review of mechanical and esthetic outcomes, J Prosthet Dent, 2019.

J. Abduo, Fit of CAD/CAM implant frameworks: a comprehensive review, J Oral Implantol. déc, vol.40, issue.6, pp.758-66, 2014.

D. Lops, R. Meneghello, L. Sbricoli, G. Savio, E. Bressan et al., Precision of the Connection Between Implant and Standard or Computer-Aided Design/Computer-Aided Manufacturing Abutments: A Novel Evaluation Method, Int J Oral Maxillofac Implants. févr, vol.33, issue.1, pp.23-30, 2018.

D. Lops, A. Parpaiola, G. Paniz, L. Sbricoli, V. R. Magaz et al., Interproximal Papilla Stability Around CAD/CAM and Stock Abutments in Anterior Regions: A 2-Year Prospective Multicenter Cohort Study, Int J Periodontics Restorative Dent, vol.37, issue.5, pp.657-65, 2017.

S. Saidin, A. Kadir, M. R. Sulaiman, E. , A. Kasim et al., Effects of different implant-abutment connections on micromotion and stress distribution: Prediction of microgap formation, Journal of Dentistry. juin, vol.40, issue.6, pp.467-74, 2012.

. Laurent-t--, Connexion implantaire interne ou externe -L'information dentaire, vol.25, pp.1467-1470, 2006.

A. R. Coppedê, E. Bersani, G. C. De-mattos-m-da, R. Rodrigues, M. De et al., Fracture Resistance of the Implant-Abutment Connection in Implants with Internal Hex and III Internal Conical Connections Under Oblique Compressive Loading: An In Vitro Study, International Journal of Prosthodontics. mai, vol.22, issue.3, pp.283-289, 2009.

D. Bozkaya, Efficiency Considerations for the Purely Tapered Interference Fit (TIF) Abutments Used in Dental Implants, Journal of Biomechanical Engineering. 27 sept, vol.126, issue.4, p.393, 2004.

L. F. Cooper, D. Tarnow, S. Froum, J. Moriarty, D. Kok et al., Comparison of Marginal Bone Changes with Internal Conus and External Hexagon Design Implant Systems: A Prospective

, Int J Periodontics Restorative Dent, vol.36, issue.5, pp.631-673, 2016.

D. Kim, H. J. Kim, S. Kim, K. Koo, T. Kim et al., Comparison of marginal bone loss between internal-and external-connection dental implants in posterior areas without periodontal or periimplant disease, J Periodontal Implant Sci. avr, vol.48, issue.2, pp.103-116, 2018.

, Sealing capability of implant-abutment junction under cyclic loading: a toluidine blue in vitro study, J Appl Biomater Funct Mater, vol.13, issue.3, pp.293-298, 2015.

, Microleakage at the Different Implant Abutment Interface: A Systematic Review -Journal of Clinical Diagn Research, vol.11, pp.10-15, 2017.

H. Zipprich, P. Weigl, C. Ratka, B. Lange, and H. Lauer, The micromechanical behavior of implantabutment connections under a dynamic load protocol. Clinical Implant Dentistry and Related Research, vol.20, pp.814-837, 2018.

C. M. Schmitt, G. Nogueira-filho, H. C. Tenenbaum, J. Y. Lai, C. Brito et al., Performance of conical abutment (Morse Taper) connection implants: a systematic review, J Biomed Mater Res A. févr, vol.102, issue.2, pp.552-74, 2014.

C. Mangano, F. Iaculli, A. Piattelli, and F. Mangano, Fixed restorations supported by Morse-taper connection implants: a retrospective clinical study with 10-20 years of follow-up, Clin Oral Implants Res, vol.26, issue.10, pp.1229-1265, 2015.

B. E. Pjetursson, C. Zarauz, M. Strasding, I. Sailer, M. Zwahlen et al., A systematic review of the influence of the implant-abutment connection on the clinical outcomes of ceramic and metal implant abutments supporting fixed implant reconstructions, Clinical Oral Implants Research, vol.29, issue.S18, pp.160-83

C. Mangano, F. Mangano, A. Piattelli, G. Iezzi, A. Mangano et al., Prospective clinical evaluation of 1920 Morse taper connection implants: results after 4 years of functional loading, Clin Oral Implants Res. mars, vol.20, issue.3, pp.254-61, 2009.

S. Gracis, K. Michalakis, P. Vigolo, P. Vult-von-steyern, M. Zwahlen et al., Internal vs. external connections for abutments/reconstructions: a systematic review, Clin Oral Implants Res, vol.23, issue.6, pp.202-218, 2012.

N. Palacios-garzón, E. Mauri-obradors, X. Roselló-llabrés, A. Estrugo-devesa, E. Jané-salas et al., Comparison of Marginal Bone Loss Between Implants with Internal and External Connections: A Systematic Review, International Journal of Oral & Maxillofacial Implants. 5 juin, vol.33, issue.3, pp.580-589, 2018.

K. Tsuruta, Y. Ayukawa, T. Matsuzaki, M. Kihara, and K. Koyano, The influence of implant-abutment connection on the screw loosening and microleakage, International Journal of Implant Dentistry. 9 avr, vol.4, p.11, 2018.

Y. Liu and J. Wang, Influences of microgap and micromotion of implant-abutment interface on marginal bone loss around implant neck. Archives of Oral Biology, vol.83, pp.153-60, 2017.

Y. Maeda, T. Satoh, and M. Sogo, In vitro differences of stress concentrations for internal and external hex implant-abutment connections: a short communication, J Oral Rehabil. janv, vol.33, issue.1, pp.75-83, 2006.

M. Esposito, H. Maghaireh, R. Pistilli, M. G. Grusovin, S. T. Lee et al., Dental implants with internal versus external connections: 5-year post-loading results from a pragmatic multicenter randomised controlled trial, European Journal of Oral Implantology. juin, vol.9, issue.2, pp.129-170, 2016.

M. C. Goiato, E. P. Pellizzer, E. Da-silva, R. Bonatto-l-da, and D. M. Santos, Is the internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? A systematic review, Oral and Maxillofacial Surgery. sept, vol.19, issue.3, pp.229-271, 2015.

L. Canullo, P. Pesce, M. Tronchi, J. Fiorellini, Y. Amari et al., Marginal soft tissue stability around conical abutments inserted with the one abutment-one time protocol after 5 years of prosthetic loading, Clin Implant Dent Relat Res. déc, vol.20, issue.6, pp.976-82, 2018.

Q. Wang, R. Dai, C. Y. Cao, H. Fang, M. Han et al., One-time versus repeated abutment connection for platform-switched implant: A systematic review and meta-analysis, PLoS ONE, vol.12, issue.10, p.186385, 2017.

P. P. Binon, Implants and components: entering the new millennium, Int J Oral Maxillofac Implants. févr, vol.15, issue.1, pp.76-94, 2000.

B. Dailey, L. Jordan, O. Blind, and B. Tavernier, Axial displacement of abutments into implants and implant replicas, with the tapered cone-screw internal connection, as a function of tightening torque, Int J Oral Maxillofac Implants. avr, vol.24, issue.2, pp.251-257, 2009.

B. Yilmaz, J. D. Seidt, E. A. Mcglumphy, and N. L. Clelland, Displacement of screw-retained single crowns into implants with conical internal connections, Int J Oral Maxillofac Implants. juin, vol.28, issue.3, pp.803-809, 2013.

T. De-murat, P. Rajzbaum, S. Szmukler-moncler, and M. Davarpanah, Connectique implantaire » in M

S. Davarpanah, P. Szmukler-moncler, K. Rajzbaum, T. Daparvanah, G. Murat et al.,

, Manuel d'implantologie Clinique 4e édition, pp.104-106, 2018.

R. J. Lazzara and S. S. Porter, Platform Switching: A New Concept in Implant Dentistry for Controlling Postrestorative Crestal Bone Levels, International Journal of Periodontics & Restorative Dentistry. janv, vol.26, issue.1, pp.8-17, 2006.

A. Aslam and B. Ahmed, Platform-Switching to Preserve Peri-Implant Bone: A Meta-Analysis, J Coll Physicians Surg Pak. avr, vol.26, issue.4, pp.315-324, 2016.

F. Guerra, W. Wagner, J. Wiltfang, S. Rocha, M. Moergel et al., Platform switch versus platform match in the posterior mandible -1-year results of a multicentre randomized clinical trial, J Clin Periodontol. mai, vol.41, issue.5, pp.521-530, 2014.

C. Valles, X. Rodríguez-ciurana, M. Clementini, M. Baglivo, B. Paniagua et al., Influence of subcrestal implant placement compared with equicrestal position on the peri-implant hard and soft tissues around platform-switched implants: a systematic review and meta-analysis, Clin Oral Investig. mars, vol.22, issue.2, pp.555-70, 2018.

S. Sivolella, R. Guazzo, E. Bressan, M. Berengo, and E. Stellini, Platform switching on wide-diameter external hex implants: a finite element analysis, J Clin Exp Dent. 1 avr, vol.5, issue.2, pp.77-82, 2013.

Á. Álvarez-arenal, L. Segura-mori, I. Gonzalez-gonzalez, H. Dellanos-lanchares, F. Sanchez-lasheras et al., Stress distribution in the transitional peri-implant bone in a single implantsupported prosthesis with platform-switching under different angulated loads, Odontology. janv, vol.105, issue.1, pp.68-75, 2017.

A. C. Freitas-júnior, E. P. Rocha, E. A. Bonfante, E. O. Almeida, R. B. Anchieta et al., Biomechanical evaluation of internal and external hexagon platform switched implant-abutment connections: An in vitro laboratory and three-dimensional finite element analysis. Dent Mater, vol.28, pp.218-228, 2012.

J. P. Macedo, J. Pereira, B. R. Vahey, B. Henriques, C. Benfatti et al., Morse taper dental implants and platform switching: The new paradigm in oral implantology, Eur J Dent. mars, vol.10, issue.1, pp.148-54, 2016.

X. Rodríguez-ciurana, X. Vela-nebot, M. Segalà-torres, J. L. Calvo-guirado, J. Cambra et al., The effect of interimplant distance on the height of the interimplant bone crest when using platform-switched implants, Int J Periodontics Restorative Dent. avr, vol.29, issue.2, pp.141-51, 2009.

M. Cassetta, D. Mambro, A. Giansanti, M. Brandetti, and G. , The Survival of Morse Cone-Connection Implants with Platform Switch, International Journal of Oral & Maxillofacial Implants. sept, vol.31, issue.5, pp.1031-1040, 2016.

Y. Nagasawa, Y. Hibino, and H. Nakajima, Retention of crowns cemented on implant abutments with temporary cements, Dent Mater J, vol.33, issue.6, pp.835-879, 2014.

H. O. Gumus, I. L. Kurtulus, and E. Kuru, Evaluation and comparison of the film thicknesses of six temporary cements before and after thermal cycling, Niger J Clin Pract. déc, vol.21, issue.12, pp.1656-61, 2018.

A. Saboury, M. Mahshid, F. Tabatabaian, and L. Moghadam, Effect of screw access hole design on the fracture resistance of implant-supported zirconia-based restorations, J Esthet Restor Dent, vol.30, issue.6, pp.545-50, 2018.

T. Jr, The Positive Relationship Between Excess Cement and Peri-Implant Disease: A Prospective Clinical Endoscopic Study, Journal of Periodontology. 1 sept, vol.80, issue.9, pp.1388-92, 2009.

A. Mazel, S. Belkacemi, P. Tavitian, G. Stéphan, D. Tardivo et al., Peri-implantitis risk factors: A prospective evaluation, J Investig Clin Dent. 7 févr, 2019.
URL : https://hal.archives-ouvertes.fr/hal-02262496

A. Quaranta, Z. W. Lim, J. Tang, V. Perrotti, and J. Leichter, The Impact of Residual Subgingival Cement on Biological Complications Around Dental Implants: A Systematic Review, Implant Dent. juin, vol.26, issue.3, pp.465-74, 2017.

, Angled Screw Channel: An Alternative to Cemented Single-Implant Restoration-three clinical example, Int J Prosthodont, vol.29, issue.1, pp.74-80, 2016.

S. Sherif, S. M. Susarla, J. Hwang, H. Weber, and R. F. Wright, Clinician-and patient-reported long-term evaluation of screw-and cement-retained implant restorations: a 5-year prospective study, Clinical Oral Investigations. déc, vol.15, issue.6, pp.993-1002, 2011.

M. Tallarico, M. Caneva, N. Baldini, F. Gatti, M. Duvina et al., Patient-centered rehabilitation of single, partial, and complete edentulism with cemented-or screw-retained fixed dental prosthesis: The First Osstem Advanced Dental Implant Research, Eur J Dent, vol.12, issue.4, pp.617-643, 2017.

M. Karl and A. Irastorza-landa, In Vitro Characterization of Original and Nonoriginal Implant Abutments, Int J Oral Maxillofac Implants. déc, vol.33, issue.6, pp.1229-1268, 2018.

X. Li and N. Mattheos,

, Shanghai Kou Qiang Yi Xue. août, vol.27, issue.4, pp.360-364, 2018.

M. Daparvanah, S. Szmukler-moncler, K. Daparvanah, and P. M. Khoury, Protocoles chirurgicaux en implantologie, pp.279-282, 2018.

M. Degidi, D. Nardi, and A. Piattelli, One abutment at one time: non-removal of an immediate abutment and its effect on bone healing around subcrestal tapered implants, Clin Oral Implants Res, vol.22, issue.11, pp.1303-1310, 2011.

X. Rodríguez, X. Vela, V. Méndez, M. Segalà, J. L. Calvo-guirado et al., The effect of abutment dis/reconnections on peri-implant bone resorption: a radiologic study of platform-switched and non-platform-switched implants placed in animals, Clin Oral Implants Res. mars, vol.24, issue.3, pp.305-316, 2013.

E. Rompen, G. Fabbri, T. Staas, V. Valantiejiene, and T. Linkevicius, Clinical investigation of the On1 twopiece abutment concept-preliminary results, Clinical Oral Implants Research, vol.29, issue.S17, pp.319-319, 2018.

, IADR Abstract Archives -Fatigue Performance of the On1 Restorative, Février, vol.24, issue.3, pp.305-316, 2019.

N. Alsabeeha, A. Payne, and M. V. Swain, Attachment systems for mandibular two-implant overdentures: a review of in vitro investigations on retention and wear features, Int J Prosthodont, vol.22, issue.5, pp.429-469, 2009.

L. Fernandez-estevan, J. Montero, S. Otaolaurruchi, E. J. , S. Ruiz et al., Interventions to Maintain Locator-Retained Mandibular Overdentures on Both External Hex and Internal Connection Implants: A Retrospective Study, Int J Oral Maxillofac Implants. août, vol.33, issue.16, pp.838-884, 2018.

, Effect of abutment angulation in the retention and durability of three overdenture attachment systems : an in vitro study, J Adv Prosthodont, vol.8, issue.1, pp.21-30, 2016.

, Fabrication of a Mandibular Implant-Supported Overdenture with a New Attachments systems : a review of current attachment, Int J Prosthodont, vol.30, issue.3, pp.245-247, 2017.