. Sotto-maior, « Influence of high insertion torque on implant placement : an anisotropic bone stress analysis

. Sotto-maior,

, Influence of forces on peri-implant bone

. Degidi, « Is insertion torque correlated to bone-implant contact percentage in the early healing period ? A histological and histomorphometrical evaluation of 17 human-retrieved dental implants

J. , « The impact of a modified cutting flute implant design on osseointegration

. Cha, « Multiscale analyses of the bone-implant interface

D. Bashutski and W. Silva, « Implant compression necrosis : current understanding and case report

. Cha, « Multiscale analyses of the bone-implant interface

. Cha,

. Trisi, « Primary stability, insertion torque and bone density of cylindric implant ad modum branemark : is there a relationship ? An in vitro study

. Cha, « Multiscale analyses of the bone-implant interface

. Duyck, « Effect of insertion torque on titanium implant osseointegration : an animal experimental study

. Eom, « Effects of different implant osteotomy preparation sizes on implant stability and bone response in the minipig mandible

. Degidi, « Is insertion torque correlated to bone-implant contact percentage in the early healing period ? A histological and histomorphometrical evaluation of 17 human-retrieved dental implants

. Duyck, « Effect of insertion torque on titanium implant osseointegration : an animal experimental study

F. Rizkallah and . Kraut, « Correlation between insertion torque and survival rates in immediately loaded implants in the maxilla: a retrospective study

. Ottoni, « Correlation between placement torque and survival of single-tooth implants

D. Santis, « Relationship between primary stability and crestal bone loss of implants placed with high insertion torque : a 3-year prospective study

. Grandi, « Clinical outcome and bone healing of implants placed with high insertion torque: 12-month results from a multicenter controlled cohort study

. Hof, « Impact of insertion torque and implant neck design on peri-implant bone level : a randomized split-mouth trial

. Khayat, « Clinical outcome of dental implants placed with high insertion torques (up to 176 ncm)

M. Walker and . Novotny,

. Cannizzaro, « Immediate versus early loading of 6.5 mm-long flapless-placed single implants : a 4-year after loading report of a split-mouth randomised controlled trial

. Ottoni, « Correlation between placement torque and survival of single-tooth implants

F. Rizkallah and . Kraut, « Correlation between insertion torque and survival rates in immediately loaded implants in the maxilla: a retrospective study

D. Santis, « Relationship between primary stability and crestal bone loss of implants placed with high insertion torque : a 3-year prospective study

. Hof, « Impact of insertion torque and implant neck design on peri-implant bone level : a randomized split-mouth trial

. Khayat, « Clinical outcome of dental implants placed with high insertion torques (up to 176 ncm)

. Grandi, « Clinical outcome and bone healing of implants placed with high insertion torque: 12-month results from a multicenter controlled cohort study

. Freitas, « The effect of implant design on insertion torque and immediate micromotion

. Berardini, « The effects of high insertion torque versus low insertion torque on marginal bone resorption and implant failure rates : a systematic review with meta-analyses

L. Li, . Zheng, and . Meta,

R. Adell, U. Lekholm, B. Rockler, and P. I. Brånemark, « A 15-year study of osseointegrated implants in the treatment of the edentulous jaw ». International journal of oral surgery 10, pp.387-416, 1981.

S. Aldahlawi, A. Demeter, T. Irinakis-;-alfonsi, F. , V. Borgia et al., « The effect of implant placement torque on crestal bone remodeling after 1 year of loading, Clinical, cosmetic and investigational dentistry, vol.10, pp.62-73, 2016.

H. Alghamdi, P. S. Anand, S. Anil-;-alsaadi, G. , M. Quirynen et al., « Undersized implant site preparation to enhance primary implant stability in poor bone density: a prospective clinical study », Journal of oral and maxillofacial surgery, vol.69, issue.4, pp.359-66, 2007.

,

A. Barone, F. Alfonsi, G. Derchi, P. Tonelli, P. Toti et al., « The effect of insertion torque on the clinical outcome of single implants : a randomized clinical trial, Clinical oral implants research, vol.18, issue.5, pp.610-625, 2003.

J. Bashutski, N. Silva, and H. L. Wang, « Implant compression necrosis : current understanding and case report, Journal of periodontology, vol.80, issue.4, pp.700-704, 2009.

G. Benic, J. Mir-mari, E. C. Hämmerle, ;. Berardini, M. et al., « The effects of high insertion torque versus low insertion torque on marginal bone resorption and implant failure rates : a systematic review with meta-analyses ». Implant dentistry 25, Loading protocols for single-implant crowns : a systematic review and meta-analysis, vol.29, pp.1-8, 1979.

F. E. Campos, J. B. Gomes, C. Marin, H. S. Teixeira, M. Suzuki et al.,

G. Cannizzaro, P. Felice, M. Leone, P. Ferri, P. Viola et al., Effect of drilling dimension on implant placement torque and early osseointegration stages : an experimental study in dogs, vol.70, pp.111-132, 2012.

J. Y. Cha, M. D. Pereira, A. A. Smith, K. S. Houschyar, X. Yin et al.,

B. R. «-multiscale-;-chrcanovic, T. Albrektsson, and A. Wennerberg, « Bone quality and quantity and dental implant failure : a systematic review and meta-analysis ». The international journal of prosthodontics 30, Journal of dental research, vol.94, issue.3, pp.69-75, 2013.

O. Cohen, Z. Ormianer, H. Tal, D. Rothamel, M. Weinreb et al., Differences in crestal boneinvestigations 20, pp.2475-80, 2016.

U. Consolo, D. Travaglini, M. Todisco, P. Trisi, S. Galli et al., Cooper, L. F. « Factors influencing primary dental implant stability remain unclear ». The journal of evidence-based dental practice 12, Histologic and biomechanical evaluation, vol.3, pp.932-981, 2003.

D. De-santis, A. Cucchi, G. Rigoni, C. Longhi, P. F. Nocini-;-degidi et al., « Implants inserted with low insertion torque values for intraoral welded full-arch prosthesis : 1-year follow-up, Relationship between primary stability, vol.5, pp.778-81, 2009.

C. R. Dhore, S. J. Snel, S. V. Jacques, I. E. Naert, X. F. Walboomers et al., « The effects of superficial roughness and design on the primary stability of dental implants, Clinical implant dentistry and related research, vol.6, pp.215-238, 2008.

J. Duyck, L. Corpas, S. Vermeiren, T. Ogawa, M. Quirynen et al.,

«. Histological, histomorphometrical, and radiological evaluation of an experimental implant design with a high insertion torque, Clinical oral implants research, vol.21, pp.877-84, 2010.

J. Duyck, R. Roesems, M. V. Cardoso, T. Ogawa, G. D. Villa-camargos et al., Effect of insertion torque on titanium implant osseointegration : an animal experimental study », Journal of oral and maxillofacial surgery, vol.26, issue.2, pp.2487-91, 2007.

M. Franchi, M. Fini, D. Martini, E. Orsini, L. Leonardi et al.,

A. C. Freitas, E. A. Bonfante, G. Giro, M. N. Janal, P. G. Coelho et al., « The effect of implant design on insertion torque and immediate micromotion », Brånemark implants and osteoporosis : a clinical exploratory study, vol.36, pp.50-56, 2001.

T. Grandi, G. Garuti, R. Samarani, P. Guazzi, and A. Forabosco, « Immediate loading of single postextractive implants in the anterior maxilla: 12-month results from a multicenter clinical study ». The journal of oral implantology, vol.38, pp.477-84, 2012.

T. Grandi, P. Guazzi, R. Samarani, and G. Grandi, « Clinical outcome and bone healing of implants placed with high insertion torque : 12-month results from a multicenter controlled cohort study ». International journal of oral and maxillofacial surgery 42, pp.516-536, 2013.

G. Greenstein, J. Et, and . Cavallaro, « Implant insertion torque : its role in achieving primary stability of restorable dental implants ». Compendium of continuing education in dentistry 38, pp.88-95, 2017.

A. Halldin, R. Jimbo, C. B. Johansson, A. Wennerberg, M. Jacobsson et al., , vol.4, pp.783-89, 2011.

C. H. Hämmerle, D. Van-steenberghe-;-pfäffikon, ». , B. Pommer, G. D. Strbac et al., « Initial torque stability of a new bone condensing dental implant. a cohort study of 140 consecutively placed implants ». The journal of oral implantology 35, The first eao consensus conference 16, vol.17, pp.120-147, 1996.

R. A. Jaffin and C. L. Berman, « The excessive loss of Branemark fixtures in type IV bone : a 5-Year Analysis », Journal of Periodontology, vol.62, issue.1, pp.2-4, 1991.

F. Javed, K. Almas, R. Crespi, G. E. Javed, F. Et et al., « Clinical outcome of dental implants placed with high insertion torques (up to 176 ncm) ». Clinical implant dentistry and related research 15, International journal of oral and maxillofacial surgery, vol.20, issue.1, pp.73-83, 1996.

H. Li, Y. Liang, Q. Zheng-;-lindh, T. , J. Gunne et al., « Meta-analysis of correlations between marginal bone resorption and high insertion torque of dental implants ». The international journal of oral & maxillofacial implants 30, Clinical oral implants research, vol.9, issue.4, pp.80-90, 1998.

C. Makary, A. Rebaudi, N. Mokbel, N. Naaman-;-marconcini, S. et al., « Longitudinal analysis on the effect of insertion torque on delayed single implants : a 3-year randomized clinical study ». Clinical implant dentistry and related research 20, Journal of international oral health, vol.20, issue.2, pp.595-602, 2002.

M. R. Norton, M. R. Norton, M. R. Norton, and C. Gamble, The influence of low insertion torque on primary stability, implant survival, and maintenance of marginal bone levels : a closed-cohort prospective study ». The international journal of oral & maxillofacial implants 32, The influence of insertion torque on the survival of immediately placed and restored single-tooth implants, vol.26, pp.79-84, 2001.

K. Okuyama, E. Abe, T. Suzuki, Y. Tamura, M. Chiba et al., « Can insertional torque predict screw loosening and related failures ? An in vivo study of pedicle screw fixation augmenting posterior lumbar interbody fusion, Spine, vol.25, issue.7, pp.858-64, 2000.

D. O'sullivan, L. Sennerby, and N. Meredith, « Measurements comparing the initial stability of five designs of dental implants : a human cadaver study, Clinical implant dentistry and related research, vol.2, pp.85-92, 2000.

J. M. Ottoni, Z. F. Oliveira, R. Mansini, A. M. Cabral-;-pantani, F. et al., « Correlation between placement torque and survival of single-tooth implants ». The international journal of oral & maxillofacial implants 20, Evolution of the internal fixation of long bone fractures. the scientific basis of biological internal fixation : choosing a new balance between stability and biology, vol.5, pp.1093-1110, 2002.

A. Rabel, S. G. Köhler, and A. Schmidt-westhausen, Clinical study on the primary stability of two, vol.3, pp.257-65, 2007.

M. Rea, D. Botticelli, S. Ricci, C. Soldini, G. G. González et al., « Correlation between insertion torque and survival rates in immediately loaded implants in the maxilla: a retrospective study, « Influence of immediate, vol.1, pp.848-58, 2001.

M. M. Shalabi, J. G. Wolke, A. J. De-ruijter, J. A. Jansen, J. Y. Shi et al., « Survival of implants using the osteotome technique with or without grafting in the posterior maxilla : a systematic review ». The international journal of oral & maxillofacial implants 31, vol.4, pp.1077-88, 2007.

S. Sivolella, E. Bressan, L. A. Salata, Z. A. Urrutia, N. P. Lang et al., « Influence of high insertion torque on implant placement : an anisotropic bone stress analysis, Hydroxyapatite coating modifies, vol.5, pp.508-522, 1992.

M. Stocchero, M. Toia, D. Cecchinato, J. P. Becktor, P. G. Coelho et al., « Biomechanical, biologic, and clinical outcomes of undersized implant surgical preparation : a systematic review ». The international journal of oral & maxillofacial implants 31, Journal of biomedical materials research, vol.15, issue.6, pp.192-203, 1994.

A. Tabassum, G. J. Meijer, J. G. Wolke, J. A. Jansen-;-tabassum, A. et al., « Primary stability, insertion torque and bone density of cylindric implant ad modum branemark : is there a relationship ? An in vitro study, High versus low implant insertion torque : a histologic, histomorphometric, and biomechanical study in the sheep mandible, vol.4, pp.837-886, 2009.

I. Turkyilmaz, U. Aksoy, E. A. Mcglumphy, ;. , L. Sennerby et al., « A retrospective study of 1925 consecutively placed immediate implants from 1988 to, Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla : a clinical study including bone density, insertion torque, and resonance frequency analysis data, vol.10, pp.134-175, 2004.