J. Voigt, G. Pedrizzetti, P. Lysyansky, T. H. Marwick, H. Houle et al., Definitions for a common standard for 2D speckle tracking echocardiography: consensus document of the EACVI/ASE/Industry Task Force to standardize deformation imaging

, European Heart Journal -Cardiovascular Imaging, vol.16, issue.1, pp.1-11, 2015.

J. S. Woo, W. Kim, Y. Ha, S. J. Kim, S. Y. Bae et al., Prognostic Value of Serial Global Longitudinal Strain Measured by Two-Dimensional Speckle Tracking Echocardiography in Patients With ST-Segment Elevation Myocardial Infarction, The American Journal of Cardiology, vol.108, issue.3, pp.340-347, 2011.

V. E. Oleynikov, V. A. Galimskaya, S. N. Kupriyanova, and N. V. Burko, Use of the Speckle tracking method for determining global parameters of heart contractility in healthy individuals, MethodsX, vol.5, pp.125-160, 2018.

V. Mor-avi, R. M. Lang, L. P. Badano, M. Belohlavek, N. M. Cardim et al., Current and Evolving Echocardiographic Techniques for the Quantitative Evaluation of Cardiac Mechanics: ASE/EAE Consensus Statement on Methodology and Indications Endorsed by the, European Journal of Echocardiography, vol.12, issue.3, pp.167-205, 2011.

M. S. Amzulscu, M. De-craene, H. Langet, A. Pasquet, D. Vancraeynest et al., Myocardial strain imaging: review of general principles, validation, and sources of discrepancies, European Heart Journal -Cardiovascular Imaging, vol.0, pp.1-15, 2009.

M. Dandel, H. Lehmkuhl, C. Knosalla, N. Suramelashvili, and R. Hetzer, Strain and strain rate imaging by echocardiography: basic concepts and clinical applicability, Current cardiology reviews, vol.5, issue.2, pp.133-148, 2009.

J. P. Sun, A. Lee, C. Wu, Y. Lam, M. Hung et al., Quantification of left ventricular regional myocardial function using two-dimensional speckle tracking echocardiography in healthy volunteers -A multi-center study, International Journal of Cardiology, vol.167, issue.2, pp.495-501, 2013.

K. Negishi, S. Lucas, T. Negishi, J. Hamilton, and T. H. Marwick, What is the Primary Source of Discordance in Strain Measurement Between Vendors: Imaging or Analysis?, Ultrasound in Medicine & Biology, vol.39, issue.4, pp.714-734, 2013.

K. E. Farsalinos, A. M. Daraban, S. Ünlü, J. D. Thomas, L. P. Badano et al., Head-to-Head Comparison of Global Longitudinal Strain Measurements among Nine Different Vendors: The EACVI/ASE Inter-Vendor Comparison Study, J Am Soc Echocardiogr, 2015.

K. Shiino, A. Yamada, M. Ischenko, B. K. Khandheria, M. Hudaverdi et al., Intervendor consistency and reproducibility of left ventricular 2D global and regional strain with two different high-end ultrasound systems, Eur Heart J Cardiovasc Imaging, vol.18, issue.6, pp.707-716, 2016.

Y. Nagata, M. Takeuchi, K. Mizukoshi, V. Wu, F. Lin et al., Intervendor variability of two-dimensional strain using vendor-specific and vendor-independent software, J Am Soc Echocardiogr, vol.28, issue.6, pp.630-671, 2015.

K. Takigiku, M. Takeuchi, C. Izumi, S. Yuda, K. Sakata et al., Normal Range of Left Ventricular 2-Dimensional Strain, Circulation Journal, vol.76, issue.11, pp.2623-2655, 2012.

A. Castel, C. Szymanski, F. Delelis, F. Levy, A. Menet et al., Prospective comparison of speckle tracking longitudinal bidimensional strain between two vendors. Archives of Cardiovascular Diseases, vol.107, pp.96-104, 2014.

N. Risum, S. Ali, N. T. Olsen, C. Jons, M. G. Khouri et al., Variability of Global Left Ventricular Deformation Analysis Using Vendor Dependent and Independent Two-Dimensional Speckle-Tracking Software in Adults, Journal of the American Society of Echocardiography, vol.25, issue.11, pp.1195-203, 2012.

S. P. Costa, T. A. Beaver, J. L. Rollor, P. Vanichakarn, P. C. Magnus et al., Quantification of the Variability Associated with Repeat Measurements of Left Ventricular Two-Dimensional Global Longitudinal Strain in a Real-World Setting, Journal of the American Society of Echocardiography, vol.27, issue.1, pp.50-54, 2014.

J. D. Thomas and L. P. Badano, EACVI-ASE-industry initiative to standardize deformation imaging: a brief update from the co-chairs, European Heart Journal -Cardiovascular Imaging, vol.14, issue.11, pp.1039-1079, 2013.

Y. J. Shimada, T. Shiota, and . Meta, Analysis and Investigation for the Source of Bias of Left Ventricular Volumes and Function by Three-Dimensional Echocardiography in Comparison With Magnetic Resonance Imaging. The American Journal of Cardiology, vol.107, pp.126-164, 2011.

L. P. Badano, F. Boccalini, D. Muraru, L. D. Bianco, D. Peluso et al., Current Clinical Applications of Transthoracic Three-Dimensional Echocardiography, J Cardiovasc Ultrasound, vol.20, issue.1, pp.1-22, 2012.

R. M. Lang, L. P. Badano, V. Mor-avi, J. Afilalo, A. Armstrong et al., Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging, European Heart Journal -Cardiovascular Imaging, vol.16, issue.3, pp.233-71, 2015.

L. P. Badano, U. Cucchini, D. Muraru, A. Nono, O. Sarais et al., Use of threedimensional speckle tracking to assess left ventricular myocardial mechanics: inter-vendor consistency and reproducibility of strain measurements, European Heart Journal -Cardiovascular Imaging, vol.14, issue.3, pp.285-93, 2013.

S. Buccheri, L. Costanzo, C. Tamburino, and M. I. , Reference Values for Real Time Three-Dimensional Echocardiography-Derived Left Ventricular Volumes and Ejection Fraction: Review and Meta-Analysis of Currently Available Studies, Echocardiography, 2015.

S. Yuda, Y. Sato, K. Abe, M. Kawamukai, H. Kouzu et al., Inter-Vendor Variability of Left Ventricular Volumes and Strains Determined by Three-Dimensional Speckle Tracking Echocardiography, Echocardiography, vol.31, issue.5, pp.597-604, 2014.

A. Heimdal, 4D strain: advenced research application for quantitative echography. GE White paper, 2011.

D. G. Altman, Some common problems in medical research, Practical Statistics for Medical Research Chapman & Hall, London, pp.396-439, 1991.

C. B. Terwee, S. D. Bot, M. R. De-boer, D. A. Van-der-windt, D. L. Knol et al., Quality criteria were proposed for measurement properties of health status questionnaires, J Clin Epidemiol, vol.60, issue.1, pp.34-42, 2007.

D. A. Kass, W. L. Maughan, K. Sunagawa, Z. M. Guo, A. Kono et al., Comparative influence of load versus ionotropic states on indexes of ventricular contractility: experimenatl and theorical analysis based on pressure-volume relationships, Circulation, vol.76, pp.1422-1458, 1987.

T. H. Marwik, Will standardization make strain a standard measurement, vol.25, pp.1318-1343, 2008.

T. H. Marwick, Measurment of strain en strain rate by echography: ready for prime time?, J Am Soc Echocardiogr, vol.25, pp.1195-203, 2012.

R. O. Mada, P. Lysyansky, A. M. Daraban, J. Duchenne, and J. U. Voigt, How to define enddiastole and end-systole? Impact of timing on strain measurements, J A Coll Cardiol Img, vol.8, issue.2, pp.148-57, 2015.

M. R. Nelson, R. T. Hurst, S. F. Raslan, S. Cha, S. Wilansky et al., Echocardiographic Measures of Myocardial Deformation by Speckle-Tracking Technologies: The Need for Standardization?, Journal of the American Society of Echocardiography, 2012.

A. Manovel, D. Dawson, B. Smith, and P. Nihoyannopoulos, Assessment of left ventricular function by different speckle-tracking software, Eur J Echocardiogr, vol.5, pp.417-438, 2010.

H. Yang, T. H. Marwick, N. Fukuda, H. Oe, M. Saito et al., Improvement in Strain Concordance between Two Major Vendors after the Strain Standardization Initiative, Journal of the American Society of Echocardiography, vol.28, issue.6, pp.642-648, 2015.

P. Biaggi, S. Carasso, P. Garceau, M. Greutmann, C. Gruner et al., Comparison of Two Different Speckle Tracking Software Systems: Does the Method Matter?: Differences between Speckle Tracking Software Systems. Echocardiography, 2011.

J. Hung, R. Lang, and F. Flachskampf, 3D echocardiography: A review of the current status and futur directions, J Am Soc Echocardiogr, vol.20, pp.213-246, 2007.

R. Lang, L. P. Badano, and W. Tsang, EAA/ASE recommendations for image acquisition and display using three-dimensional echocardiography, J Am Soc Echocardiogr, vol.25, pp.3-46, 2012.

J. L. Dorosz, D. C. Lezotte, and D. A. Weitzenkamp, Performance of 3D-dimensional echocardiography in measuring left ventricular volumes and ejection fraction: A systematic review and meta-analysis, J A Coll Cardiol, vol.59, pp.1799-808, 2012.

T. H. Marwik, Application of 3D echocardiography to everyday practice: Development of normal ranges is strep 1, JACC Cardiovasc Imaging, vol.5, pp.1198-200, 2012.

I. Annexe,

, Mesure de l'épaisseur du septum interventriculaire (SIV) et de la paroi postérieure (PP) en diastole et en systole

. ?-mesure-du-diamètre-de-la-chambre-de-chasse-du and . Vg,

?. Étude-morphologique-bidimensionnelle, 2D) de la valve mitrale et aortique : recherche d'un prolapsus, d'une restriction

. ?-Étude-en, Doppler couleur de la valve mitrale et aortique : recherche d'une insuffisance valvulaire modérée à sévère

, Étude de la cinétique myocardique ventriculaire gauche : recherche de troubles de la cinétique segmentaire

P. Petit-axe,

, Étude de la cinétique myocardique ventriculaire gauche et droite : recherche de troubles de la cinétique segmentaire

, Étude morphologique 2D de la valve mitrale et aortique : recherche d'un prolapsus, d'une restriction, d'une dystrophie ou d'une calcification

. ?-Étude-en, Doppler couleur de la valve mitrale et aortique : recherche d'une insuffisance valvulaire modérée à sévère

, Acquisition des images échographiques cardiaques pour mesure du strain et calcul de la FEVG en 3D sur les deux échographes, GE Vivid E9 et Philips Epiq 7, sur quatre cycles cardiaques en apnée en fin d'inspiration en : ? Parasternale grand axe en 2D

, ? Parasternale petit axe en 2D

, ? Apicale 4cavités en 2D

, ? Apicale 3 cavités en 2D

, ? Apical 2 cavités en 2D

. ?-apicale-en-3d,

. Serment-d'hippocrate,

, En présence des Maîtres de cette faculté et de mes chers condisciples, je promets et je jure d'être fidèle aux lois de l'honneur et de la probité dans l'exercice de la médecine

, Admise dans l'intérieur des maisons, mes yeux ne verront pas ce qui s'y passe, ma langue taira les secrets qui me seront confiés et mon état ne servira pas à corrompre les moeurs ni à favoriser le crime

, Respectueuse et reconnaissante envers mes maîtres, je rendrai à leurs enfants l'instruction que j'ai reçue de leurs pères

, Que les hommes m'accordent leur estime si je suis fidèle à mes promesses. Que je sois couverte d'opprobre et méprisée de mes confrères si j'y manque

, Conseil de l'ordre des médecins Serment d'Hippocrate

, Au moment d'être admise à exercer la médecine, je promets et je jure d'être fidèle aux lois de l'honneur et de la probité

, Mon premier souci sera de rétablir, de préserver ou de promouvoir la santé dans tous ses éléments, physiques et mentaux, individuels et sociaux

, Je respecterai toutes les personnes, leur autonomie et leur volonté, sans aucune discrimination selon leur état ou leurs convictions. J'interviendrai pour les protéger si elles sont affaiblies, vulnérables ou menacées dans leur intégrité ou leur dignité. Même sous la contrainte

, Je ne tromperai jamais leur confiance et n'exploiterai pas le pouvoir hérité? des circonstances pour forcer les consciences

, Je ne me laisserai pas influencer par la soif du gain ou la recherche de la gloire

, Admise dans l'intimité des personnes, je tairai les secrets qui me seront confiés. Reçue à l'intérieur des maisons, je respecterai les secrets des foyers et ma conduite ne servira pas à corrompre les moeurs

, Je ne prolongerai pas abusivement les agonies. Je ne provoquerai jamais la mort délibérément

, Je n'entreprendrai rien qui dépasse mes compétences. Je les entretiendrai et les perfectionnerai pour assurer au mieux les services qui me seront demandés

, J'apporterai mon aide à mes confrères ainsi qu'à leurs familles dans l'adversité

, Que les hommes et mes confrères m'accordent leur estime si je suis fidèle à mes promesses

, que je sois déshonorée et méprisée si j'y manque