TRANSFORM (Multicenter Experience With Rapid Deployment Edwards INTUITY Valve System for Aortic Valve Replacement) US clinical trial: Performance of a rapid deployment aortic valve, J Thorac Cardiovasc Surg, vol.153, issue.2, pp.241-51, 2017. ,
Long-term outcomes of a rapid deployment aortic valve: data up to 5 years ?, Eur J Cardiothorac Surg, vol.52, issue.2, pp.281-288, 2017. ,
A Meta-Analysis of Sutureless or Rapid-Deployment Aortic Valve Replacement, Thorac cardiovasc Surg, vol.64, issue.05, pp.400-409, 2016. ,
Conventional versus rapiddeployment aortic valve replacement: a single-centre comparison between the Edwards Magna valve and its rapid-deployment successor, Interact CardioVasc Thorac Surg, vol.22, issue.6, pp.799-805, 2016. ,
Conduction Disorders After Sutureless Aortic Valve Replacement, Ann Thorac Surg, vol.103, issue.4, pp.1254-60, 2017. ,
AHA/ACCF/HRS recommendations for the standardization and interpretation of the electrocardiogram: part III: intraventricular conduction disturbances: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society. Endorsed by the International Society for Computerized Electrocardiology, J Am Coll Cardiol, vol.53, issue.11, pp.976-81, 2009. ,
Rapid-deployment aortic valve replacement versus standard bioprosthesis implantation, J Card Surg, vol.32, issue.6, pp.322-329, 2017. ,
Rapid Deployment Versus Conventional Bioprosthetic Valve Replacement for Aortic Stenosis, J Am Coll Cardiol, vol.71, issue.13, pp.1417-1445, 2018. ,
Early and Mid-Term Results of Rapid Deployment Valves: The Intuity Italian Registry (INTU-ITA), Ann Thorac Surg, vol.106, issue.6, pp.1742-1751, 2018. ,
Permanent Pacemaker Implantation After Rapid Deployment Aortic Valve Replacement, Ann Thorac Surg, vol.106, issue.3, pp.685-90, 2018. ,
Early Outcomes with Rapiddeployment vs Stented Biological Valves: A Propensity-match Analysis, Semin Thorac Cardiovasc Surg, vol.30, issue.1, pp.16-23, 2017. ,
Inverse Relationship Between Membranous Septal Length and the Risk of Atrioventricular Block in Patients Undergoing Transcatheter Aortic Valve Implantation, J Am Coll Cardiol Intv, vol.8, issue.9, pp.1218-1246, 2015. ,
Sutureless aortic valve replacement with Perceval bioprosthesis: are there predicting factors for postoperative pacemaker implantation?, Interact Cardiovasc Thorac Surg, vol.22, issue.3, pp.253-261, 2016. ,
Early Predictors of Permanent Pacemaker Implantation in Sutureless Aortic Valve Replacement with Perceval Bioprosthesis: A Conduction Disorders Analysis, J Heart Health Cir, vol.1, issue.1, 2017. ,
New postoperative conduction abnormalities after the implantation of a rapid-deployment aortic valve prosthesis, Interact Cardiovasc Thorac Surg, vol.28, issue.4, pp.581-587, 2019. ,
Prognostic significance of newly acquired bundle branch block after aortic valve replacement, Am J Cardiol, vol.94, issue.8, pp.1008-1019, 2004. ,
ESC Guidelines on cardiac pacing and cardiac resynchronization therapyThe Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC), Eur Heart J, vol.34, issue.29, pp.2281-329, 2013. ,
Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons, J Am Coll Cardiol, vol.51, issue.21, pp.1-62, 2008. ,
ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay: Executive Summary: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines, and the Heart Rhythm Society, Circulation, vol.140, issue.8, pp.333-81, 2018. ,
A simple modification to lower incidence of heart block with sutureless valve implantation, J Thorac Cardiovasc Surg, vol.152, issue.2, pp.630-632, 2016. ,
Incidence and predictors of new-onset atrioventricular block requiring pacemaker implantation after sutureless aortic valve replacement, Interact CardioVasc Thorac Surg, vol.23, issue.6, pp.861-869, 2016. ,
Edwards Intuity Aortic Bioprosthesis in Patient with Bicuspid Aortic Valve, Curr Health Sci J, vol.42, issue.3, pp.289-92, 2016. ,
Sutureless aortic valve replacement in patients who have bicuspid aortic valve, J Thorac Cardiovasc Surg, vol.150, issue.4, pp.851-858, 2015. ,
, Références des images
, 1-2) Grades de Médecin Général inspecteur / Médecin chef des services (classe normale et hors classe)
, Grades et galons du Service de santé des armées. www.defense.gouv.fr ? (Page 1) Insigne de l'Ecole du Val de Grâce
, Cellule communication HIA Sainte Anne ? (Page 6) La "Phrase du Baron Percy" : Gravée dans le marbre dans le grand hall de l'École, la "Phrase du Baron Percy" est la définition, encore actuelle, du médecin militaire ; elle est la devise des médecins militaires et est connue de tous les Santards