M. Davarpanah, S. Szmukler-moncler, . Ph, K. Rajzbaum, and G. Davarpanah, Manuel d'implantologie clinique 3e édition Concepts

M. Davarpanah, S. Szmukler-moncler, P. Rajzbaum, B. Jacubowicz-kohen, M. Caraman et al., Les implants en odontologie: l'essentiel de la pratique [Internet]. Rueil-Malmaison, France: Éditions CdP, DL 2015; 2015. xii+169 Available from: http://www.sudoc.abes.fr/DB=2.1/SRCH?IKT=12&TRM=188942483 3 Les implants en odontologie [Internet] Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels Available from, Int J Periodontics Restorative Dent [Internet], vol.26, issue.1, pp.9-1716515092, 2004.

H. Nickenig, M. Wichmann, K. Schlegel, E. Nkenke, and S. Eitner, Radiographic evaluation of marginal bone levels adjacent to parallel-screw cylinder machined-neck implants and rough-surfaced microthreaded implants using digitized panoramic radiographs Available from, Clin Oral Implants Res Feb, vol.20, issue.6, pp.550-554, 2009.

T. Laurent, La connexion implantaire interne ou externe? L'information Dent, pp.1467-70, 2006.

W. Nicolas and P. , Les Différents types de connexions implantaires : Description, avantages, inconvénients et critères de choix, 2013.

R. Pessoa, L. Muraru, E. Júnior, L. Vaz, J. Sloten et al., Influence of Implant Connection Type on the Biomechanical Environment of Immediately Placed Implants - CT-Based Nonlinear, Three-Dimensional Finite Element Analysis, Clinical Implant Dentistry and Related Research, vol.13, 2009.
DOI : 10.1111/j.1708-8208.2009.00155.x

C. Nicolas, Critères de choix d'un pilier implantaire en prothèse fixée [Internet] Université de Lorraine, 2016.

J. Guillaume, La connexion implant-prothèse Available from, Actual Odontostomatol (Paris), issue.264, pp.9-13, 2013.
DOI : 10.1051/aos/2013403

B. Herpe, Connexion Implant-Pilier : analyse des choix stratégiques des grands systèmes implantaires, 2014.

S. Szmukler-moncler, M. Davarpanah, P. Khoury, B. Jacubowicz-kohen, and H. M. , Manuel d'implantologie clinique, 2e édition, 2008.

A. Berberi, G. Tehini, K. Rifai, F. Bou-nasser-eddine, B. Badran et al., Leakage evaluation of original and compatible implant-abutment connections: In vitro study using Rhodamine B, Journal of Dental Biomechanics, vol.5, issue.0, 2014.
DOI : 10.1177/1758736014547143

R. Faria, G. May, L. , K. De-vasconcellos, D. et al., Evaluation of the bacterial leakage along the implant-abutment interface, Journal of Dental Implants, vol.1, issue.2
DOI : 10.4103/0974-6781.91280

S. Dibart, D. Warbington, M. Ming, F. Su, D. Ms et al., In Vitro Evaluation of the Implant-Abutment Bacterial Seal : The Locking Taper System, 2005.

B. Jakubowicz-kohen, T. Rouach, and C. Rignon-bret, Esthétique et préservation tissulaire péri-implantaire. L'information Dent, pp.1268-73, 2008.

C. Do-nascimento, P. Miani, V. Pedrazzi, R. Gonçalves, R. Ribeiro et al., Leakage of saliva through the implant-abutment interface: in vitro evaluation of three different implant connections under unloaded and loaded conditions Available from, Int J Oral Maxillofac Implants [Internet], vol.27, issue.3, pp.551-60, 2012.

L. Steinebrunner, S. Wolfart, K. Bössmann, and M. Kern, In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems Available from, Int J Oral Maxillofac Implants [Internet], vol.20, issue.6, pp.875-81, 2005.

L. Canullo, D. Penarrocha-oltra, C. Soldini, F. Mazzocco, M. Penarrocha et al., Microbiological assessment of the implant-abutment interface in different connections: cross-sectional study after 5??years of functional loading, Clinical Oral Implants Research, vol.21, issue.Suppl 2, pp.426-460, 2015.
DOI : 10.1111/clr.12383

L. Persson, U. Lekholm, A. Leonhardt, G. Dahlen, and J. Lindhe, Bacterial colonization on internal surfaces of Branemark systemR implant components, Clinical Oral Implants Research, vol.7, issue.2, pp.90-95, 1996.
DOI : 10.1034/j.1600-0501.1996.070201.x

I. Ericsson, K. Nilner, B. Klinge, and P. Glantz, Radiographical and histological characteristics of ssubmerged and nonsubmerged titanium implants. An experimental study in the Labrador dog., Clinical Oral Implants Research, vol.7, issue.1, pp.20-26, 1996.
DOI : 10.1034/j.1600-0501.1996.070103.x

M. Fauroux, B. Levallois, J. Yachouh, and J. Torres, Assessment of leakage at the implant-abutment connection using a new gas flow method Available from, Int J Oral Maxillofac Implants [Internet], vol.27, issue.6, pp.1409-1421, 2012.

M. Quirynen and S. Van, Bacterial colonization of the internal part of two-stage implants An in vivo study Clin Oral Implants Res [Internet] Available from, pp.158-61, 1993.

D. Callan, C. Cobb, and K. Williams, DNA Probe Identification of Bacteria Colonizing Internal Surfaces of the Implant-Abutment Interface: A Preliminary Study, Journal of Periodontology, vol.76, issue.1, pp.115-135, 2005.
DOI : 10.1902/jop.2005.76.1.115

W. Teixeira, R. Ribeiro, S. Sato, and V. Pedrazzi, Microleakage into and from two-stage implants: an in vitro comparative study Available from, Int J Oral Maxillofac Implants [Internet], vol.26, issue.1, pp.56-62, 2011.

V. Jansen, G. Conrads, and E. Richter, Microbial leakage and marginal fit of the implantabutment interface Available from, Int J Oral Maxillofac Implants, vol.12, issue.4, pp.527-567, 1997.

S. Harder, B. Dimaczek, Y. Açil, H. Terheyden, S. Freitag-wolf et al., Molecular leakage at implant-abutment connection???in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration, Clinical Oral Investigations, vol.60, issue.4, pp.427-459, 2010.
DOI : 10.1007/s00784-009-0317-x

M. Gross, I. Abramovich, and E. Weiss, Microleakage at the abutment-implant interface of osseointegrated implants: a comparative study Available from, Int J Oral Maxillofac Implants [Internet], vol.14, issue.1, pp.94-100, 2016.

P. Coelho, P. Sudack, M. Suzuki, K. Kurtz, G. Romanos et al., evaluation of the implant abutment connection sealing capability of different implant systems, Journal of Oral Rehabilitation, vol.12, issue.12, pp.917-941, 2008.
DOI : 10.1111/j.1365-2842.2008.01886.x

A. Berberi, G. Tehini, K. Rifai, F. Bou-nasser-eddine, E. Zein et al., In Vitro Evaluation of Leakage at Implant-Abutment Connection of Three Implant Systems Having the Same Prosthetic Interface Using Rhodamine B, International Journal of Dentistry, vol.14, issue.1, 2014.
DOI : 10.1111/j.1600-0501.2009.01837.x

J. Hermann and J. Schoolfield, Influence of the Size of the Microgap on Crestal Bone Changes Around Titanium Implants. A Histometric Evaluation of Unloaded Non-Submerged Implants in the Canine Mandible, Journal of Periodontology, vol.72, issue.10, 2001.
DOI : 10.1902/jop.2001.72.10.1372

M. Tesmer, S. Wallet, T. Koutouzis, and T. Lundgren, Bacterial Colonization of the Dental Implant Fixture???Abutment Interface: An In Vitro Study, Journal of Periodontology, vol.80, issue.12, pp.1991-1998, 2009.
DOI : 10.1902/jop.2009.090178

M. Jaworski, A. Melo, C. Picheth, and I. Sartori, Analysis of the Bacterial Seal at the Implant-Abutment Interface in External-Hexagon and Morse Taper ? Connection Implants : An In Vitro Study Using a New Methodology, Int J Oral Maxillofac Implants, vol.27, pp.1091-1096, 2012.

D. Tripodi, G. Vantaggiato, A. Scarano, V. Perrotti, A. Piattelli et al., An In Vitro Investigation Concerning the Bacterial Leakage at Implants With Internal Hexagon and Morse Taper Implant-Abutment Connections, Implant Dentistry, vol.21, issue.4, pp.335-344, 2012.
DOI : 10.1097/ID.0b013e31825cd472

M. Schwarz, Mechanical complications of dental implants, Clinical Oral Implants Research, vol.11, 2000.
DOI : 10.1034/j.1600-0501.2000.011S1156.x

T. Koutouzis, S. Wallet, N. Calderon, and T. Lundgren, Bacterial Colonization of the Implant???Abutment Interface Using an In Vitro Dynamic Loading Model, Journal of Periodontology, vol.82, issue.4, pp.613-621, 2011.
DOI : 10.1902/jop.2010.100415

E. Cláudio, L. Chaves, . De, E. Décio, C. Bisognin et al., Evaluation of Implant-Abutment Microgap and Bacterial Leakage in Five External-Hex Implant Systems: An In Vitro Study, 2012.

T. Morneburg and P. Pröschel, Measurement of masticatory forces and implant loads: a methodologic clinical study Available from, Int J Prosthodont [Internet], vol.15, issue.1, pp.20-27, 1989.

T. Morneburg, In vivo forces on implants influenced by occlusal scheme and food consistency, Int J Prosthodont, vol.16, issue.5, pp.481-487, 2003.

C. Tang, S. Liu, G. Zhou, J. Yu, G. Zhang et al., Nonlinear finite element analysis of three implant???abutment interface designs, International Journal of Oral Science, vol.12, issue.2, pp.101-109, 2012.
DOI : 10.1016/j.joms.2010.12.006

E. Almeida, A. Jr, E. Bonfante, L. Marotta, N. Silva et al., Mechanical Testing of Implant-Supported Anterior Crowns with Different Implant/Abutment Connections, The International Journal of Oral & Maxillofacial Implants, vol.28, issue.1, pp.103-111, 2013.
DOI : 10.11607/jomi.2443

A. Balik, M. Karatas, and H. Keskin, Effects of different abutment connecion designs on the stress distribution around five different implants: a 3-dimentional finite element analysis, J Oral Implantol, vol.XXXIX, issue.1, pp.491-497, 2012.

S. Saidin, A. Kadir, M. Sulaiman, E. , A. Kasim et al., Effects of different implant???abutment connections on micromotion and stress distribution: Prediction of microgap formation, Journal of Dentistry, vol.40, issue.6, pp.467-74, 2012.
DOI : 10.1016/j.jdent.2012.02.009

P. Asvanund and S. Morgano, Photoelastic stress analysis of external versus internal implant-abutment connections, The Journal of Prosthetic Dentistry, vol.106, issue.4, pp.266-71, 2011.
DOI : 10.1016/S0022-3913(11)60128-5

P. W. Zipprich and B. L. , Micromovements at the Implant-Abutment Interface: Measurement, Causes, and Consequences, Implantologie, 2007.

G. Greenstein, J. Cavallaro, and D. Tarnow, Assessing bone's adaptive capacity around dental implants, The Journal of the American Dental Association, vol.144, issue.4, 2013.
DOI : 10.14219/jada.archive.2013.0129

A. Freitas-júnior, E. Rocha, E. Bonfante, E. Almeida, R. Anchieta et al., Biomechanical evaluation of internal and external hexagon platform switched implant-abutment connections: An in vitro laboratory and three-dimensional finite element analysis, Dental Materials, vol.28, issue.10, pp.218-246, 2012.
DOI : 10.1016/j.dental.2012.05.004

L. Machado, E. Bonfante, R. Anchieta, S. Yamaguchi, and P. Coelho, Implant-Abutment Connection Designs for Anterior Crowns, Implant Dentistry, vol.22, issue.5, pp.540-545, 2013.
DOI : 10.1097/ID.0b013e31829f1f2d

B. Merz, S. Hunenbart, and U. Belser, Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection Available from, Int J Oral Maxillofac Implants [Internet], vol.15, issue.4, pp.519-545, 2000.

Y. Maeda, T. Satoh, and M. Sogo, In vitro differences of stress concentrations for internal and external hex implant-abutment connections: a short communication, Journal of Oral Rehabilitation, vol.13, issue.1, pp.75-83, 2006.
DOI : 10.1067/mpr.2001.116230

A. Coppedê, E. Bersani, M. De-mattos, R. Rodrigues, I. Sartori et al., Fracture resistance of the implant-abutment connection in implants with internal hex and internal conical connections under oblique compressive loading: an in vitro study, Int J Prosthodont, vol.22, issue.3, pp.283-289, 2009.

R. Segundo, H. Oshima, I. Da-silva, B. Jr, . Lh et al., Stress distribution of an internal connection implant prostheses set: a 3D finite element analysis, Stomatol Balt Dent Maxillofac J, vol.11, issue.2, pp.55-64, 2009.

M. Goiato, A. Pesqueira, R. Falcón-antenucci, D. Santos, M. Haddad et al., Stress distribution in implant-supported prosthesis with external and internal implant-abutment connections, Acta Odontologica Scandinavica, vol.30, issue.2, pp.283-291, 2012.
DOI : 10.3109/00016357.2012.672823

A. Freitas-júnior, E. Almeida, E. Bonfante, N. Silva, and P. Coelho, Reliability and failure modes of internal conical dental implant connections, Clinical Oral Implants Research, vol.37, issue.2, pp.197-202, 2013.
DOI : 10.1111/j.1600-0501.2012.02443.x

L. Steinebrunner, S. Wolfart, K. Ludwig, and M. Kern, Implant-abutment interface design affects fatigue and fracture strength of implants, Clinical Oral Implants Research, vol.20, issue.12, pp.1276-84, 2008.
DOI : 10.1111/j.1600-0501.2008.01581.x

A. Khraisat, R. Stegaroiu, S. Nomura, and O. Miyakawa, Fatigue resistance of two implant/abutment joint designs, The Journal of Prosthetic Dentistry, vol.88, issue.6, pp.604-614, 2002.
DOI : 10.1067/mpr.2002.129384