R. Adell, U. Lekholm, B. Rockler, and P. I. Brånemark, A 15-year study of osseointegrated implants in the treatment of the edentulous jaw, International Journal of Oral Surgery, vol.10, issue.6, pp.387-416, 1981.
DOI : 10.1016/S0300-9785(81)80077-4

K. Akça, M. C. Et, and . Cehreli, « A photoelastic and strain-gauge analysis of interface force transmission of internal-cone implants ». The international journal of periodontics & restorative dentistry 28, pp.391-99, 2008.

C. Arnhart, A. M. Kielbassa, R. Martinez-de-fuentes, M. Goldstein, J. Jackowski et al., Comparison of variable-thread tapered implant designs to a standard tapered implant design after immediate loading. a 3-year multicentre randomised controlled trial, European journal of oral implantology, vol.5, issue.2, pp.123-159, 2012.

B. Assenza, D. Tripodi, A. Scarano, V. Perrotti, A. Piattelli et al., Bacterial Leakage in Implants With Different Implant???Abutment Connections: An In Vitro Study, Journal of Periodontology, vol.83, issue.4, pp.491-9710, 1902.
DOI : 10.1902/jop.2011.110320

M. A. Atieh, H. M. Ibrahim, and A. H. Atieh, Platform Switching for Marginal Bone Preservation Around Dental Implants: A Systematic Review and Meta-Analysis, Journal of Periodontology, vol.81, issue.10, 2010.
DOI : 10.1902/jop.2010.100232

S. Baixe, G. Fauxpoint, Y. Arntz, and E. O. Etienne, « Microgap between zirconia abutments and titanium implants ». The international journal of oral & maxillofacial implants 25, pp.455-60, 2010.

S. R. Bernardes, C. A. De-araujo, A. J. Neto, P. Simamoto-junior, and F. D. Das-neves, « Photoelastic analysis of stress patterns from different implant-abutment interfaces ». The international journal of oral & maxillofacial implants 24, pp.781-89, 2009.

H. Bilhan, O. Kutay, S. Arat, A. Cekici, and M. C. Cehreli, « Astra tech, Brånemark, and ITI implants in the rehabilitation of partial edentulism: two-year results ». Implant dentistry 19, pp.437-483, 2010.

L. Canullo, D. Penarrocha-oltra, C. Soldini, F. Mazzocco, M. Penarrocha et al., Microbiological assessment of the implant-abutment interface in different connections: cross-sectional study after 5??years of functional loading, Clinical Oral Implants Research, vol.21, issue.Suppl 2, pp.426-460, 2015.
DOI : 10.1097/ID.0b013e31825cd472

L. Canullo, J. C. Rosa, V. S. Pinto, C. E. Francischone, and E. W. Götz, « Inward-inclined implant platform for the amplified platform-switching concept: 18-month follow-up report of a prospective randomized matched-pair controlled trial ». The international journal of oral & maxillofacial implants 27, pp.927-961, 2012.

M. Cehreli, J. Duyck, M. De-cooman, R. Puers, and E. I. Naert, « Implant design and interface force transfer. A photoelastic and strain-gauge analysis ». Clinical oral implants research 15, pp.249-57, 2004.

C. Goiato, M. , A. A. Pesqueira, R. M. Falcón-antenucci, D. M. Santos et al., « Stress distribution in implant-supported prosthesis with external and internal implant-abutment connections ». Acta odontologica scandinavica 71, 2013.

L. F. Cooper, G. Reside, C. Stanford, C. Barwacz, J. Feine et al., « A multicenter randomized comparative trial of implants with different abutment interfaces to replace anterior maxillary single teeth ». The international journal of oral & maxillofacial implants 30, pp.622-654, 2015.

R. Crespi, P. Capparè, and E. E. Gherlone, « Radiographic evaluation of marginal bone levels around platform-switched and non-platform-switched implants used in an immediate loading protocol ». The international journal of oral & maxillofacial implants 24, pp.920-946, 2009.

C. Dagorne, J. Malet, G. Bizouard, F. Mora, H. Rangé et al., Clinical evaluation of two dental implant macrostructures on peri-implant bone loss: a comparative, retrospective study, Clinical Oral Implants Research, vol.75, issue.Suppl. 4, 2015.
DOI : 10.1902/jop.2004.75.9.1233

H. De-bruyn, V. Christiaens, R. Doornewaard, M. Jacobsson, J. Cosyn et al., Implant surface roughness and patient factors on long-term peri-implant bone loss, Periodontology 2000, vol.35, issue.1, pp.218-245, 2000.
DOI : 10.1111/j.1600-051X.2008.01274.x

S. Dibart, M. Warbington, M. F. Su, and E. Z. Skobe, « In vitro evaluation of the implant-abutment bacterial seal: the locking taper system ». The international journal of oral & maxillofacial implants 20, pp.732-769, 2005.

R. Dudhia, P. A. Monsour, N. W. Savage, and R. J. Wilson, « Accuracy of angular measurements and assessment of distortion in the mandibular third molar region on panoramic radiographs ». Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics 111, 2011.

N. Eid, G. Girot, E. Robbiani, and E. D. Dot, « Dentisterie fondée sur la preuve. proposition de grilles de lecture simplifiées. » Réalités cliniques 15, pp.105-114, 2004.

N. Enkling, P. Jöhren, J. Katsoulis, S. Bayer, P. Jervøe-storm et al., Influence of Platform Switching on Bone-level Alterations, Journal of Dental Research, vol.24, issue.12_suppl, pp.12-139, 2013.
DOI : 10.1097/01.id.0000226788.19742.32

I. Ericsson, L. G. Persson, T. Berglundh, C. P. Marinello, J. Lindhe et al., Different types of inflammatory reactions in peri-implant soft tissues, Journal of Clinical Periodontology, vol.6, issue.suppl., pp.255-61, 1995.
DOI : 10.1902/jop.1977.48.3.125

M. Esposito, H. Maghaireh, R. Pistilli, M. G. Grusovin, S. T. Lee et al., « Dental implants with internal versus external connections: 5-year post-loading results from a pragmatic multicenter randomised controlled trial, European journal of oral implantology, vol.9, issue.2, pp.129-170, 2016.

M. Fauroux, C. Anxionnat, C. Biens, M. Mechali, O. Romieu et al., « Fuites de la connexion implantaire: comparaison de plusieurs types d'implants par la méthode de diffusion gazeuse ». Revue de stomatologie, de chirurgie maxillo-faciale et de chirurgie orale 115, 2014.

R. Fürhauser, D. Florescu, T. Benesch, R. Haas, G. Mailath et al., « Evaluation of soft tissue around single-tooth implant crowns: the pink esthetic score ». Clinical oral implants research 16, 2005.

B. A. Gultekin, P. Gultekin, B. Leblebicioglu, C. Basegmez, and E. S. Yalcin, « Clinical evaluation of marginal bone loss and stability in two types of submerged dental implants ». The international journal of oral & maxillofacial implants 28, pp.815-838, 2013.

T. Haraldson, « A photoelastic study of some biomechanical factors affecting the anchorage of osseointegrated implants in the jaw ». Scandinavian journal of plastic and reconstructive surgery 14, pp.3-209, 1980.

J. S. Hermann, D. L. Cochran, P. V. Nummikoski, and E. D. Buser, Crestal Bone Changes Around Titanium Implants. A Radiographic Evaluation of Unloaded Nonsubmerged and Submerged Implants in the Canine Mandible, Journal of Periodontology, vol.68, issue.11, 1997.
DOI : 10.1902/jop.1997.68.11.1117

J. S. Hermann, J. D. Schoolfield, R. K. Schenk, D. Buser, and D. L. Cochran, Influence of the Size of the Microgap on Crestal Bone Changes Around Titanium Implants. A Histometric Evaluation of Unloaded Non-Submerged Implants in the Canine Mandible, Journal of Periodontology, vol.72, issue.10, 2001.
DOI : 10.1902/jop.2001.72.10.1372

P. Hernigou, S. Queinnec, and C. H. Flouzat-lachaniette, One hundred and fifty??years of history of the Morse taper: from Stephen A. Morse in 1864 to complications related to modularity in hip arthroplasty, International Orthopaedics, vol.72, issue.14, pp.2081-88, 2013.
DOI : 10.2106/00004623-199072040-00021

A. Kaminaka, T. Nakano, S. Ono, T. Kato, and E. H. Yatani, Cone-Beam Computed Tomography Evaluation of Horizontal and Vertical Dimensional Changes in Buccal Peri-Implant Alveolar Bone and Soft Tissue: A 1-Year Prospective Clinical Study, Clinical Implant Dentistry and Related Research, vol.2, issue.Suppl 1, p.17
DOI : 10.1034/j.1600-0501.1991.020206.x

H. Khorshidi, S. Raoofi, A. Moattari, A. Bagheri, and M. H. Kalantari, « In vitro evaluation of bacterial leakage at implant-abutment connection: an 11-degree morse taper compared to a butt joint connection », International journal of biomaterials, pp.8527849-8527859, 2016.

T. Kitagawa, Y. Tanimoto, M. Odaki, K. Nemoto, and E. M. Aida, Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system, Journal of Biomedical Materials Research Part B: Applied Biomaterials, vol.14, issue.2, 2005.
DOI : 10.1002/jbm.b.30328

R. J. Lazzara, S. S. Et, and . Porter, « Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels ». The international journal of periodontics & restorative dentistry 26, pp.9-17, 2006.

R. Mengel, B. Kruse, and L. Flores-de-jacoby, Digital Volume Tomography in the Diagnosis of Peri-Implant Defects: An In Vitro Study on Native Pig Mandibles, Journal of Periodontology, vol.77, issue.7, pp.1234-4110050424, 1902.
DOI : 10.1902/jop.2006.050424

B. R. Merz, S. Hunenbart, and U. C. Belser, « Mechanics of the implant-abutment connection: an 8- degree taper compared to a butt joint connection ». The international journal of oral & maxillofacial implants 15, pp.519-545, 2000.

C. Nascimento, P. K. Do, V. Miani, R. B. Pedrazzi, R. F. Gonçalves et al., « Leakage of saliva through the implant-abutment interface: in vitro evaluation of three different implant connections under unloaded and loaded conditions ». The international journal of oral & maxillofacial implants 27, pp.551-60, 2012.

R. S. Nishioka, L. G. De-vasconcellos, G. N. De-melo, and . Nishioka, Comparative Strain Gauge Analysis of External and Internal Hexagon, Morse Taper, and Influence of Straight and Offset Implant Configuration, Implant Dentistry, vol.20, issue.2, pp.24-32, 2011.
DOI : 10.1097/ID.0b013e318211fce8

E. P. Pellizzer, R. I. Carli, R. M. Falcón-antenucci, F. R. Verri, M. C. Goiato et al., « Photoelastic analysis of stress distribution with different implant systems ». The journal of oral implantology 40, pp.117-139, 2014.

M. A. Peñarrocha-diago, A. J. Flichy-fernández, R. Alonso-gonzález, D. Peñarrocha-oltra, and J. Balaguer-martínez, Peñarrocha-Diago. « Influence of implant neck design and implant-abutment connection type on peri-implant health. radiological study ». Clinical oral implants research 24, 2013.

J. Pereira, C. S. Morsch, B. Henriques, R. M. Nascimento, C. A. Benfatti et al., « Removal torque and biofilm accumulation at two dental implant-abutment joints after fatigue ». The international journal of oral & maxillofacial implants 31, pp.813-832, 2016.

J. Perriard, W. A. Wiskott, A. Mellal, S. S. Scherrer, J. Botsis et al., « Fatigue resistance of iti implant-abutment connectors --a comparison of the standard cone with a novel internally keyed design ». Clinical oral implants research 13, pp.542-591, 2002.

R. S. Pessoa, L. Muraru, E. M. Júnior, L. G. Vaz, J. V. Sloten et al., « Influence of implant connection type on the biomechanical environment of immediately placed implants : CT-based nonlinear, three-dimensional finite element analysis ». Clinical implant dentistry and related research 12, 2010.

R. S. Pessoa, R. M. Sousa, L. M. Pereira, F. D. Neves, F. J. Bezerra et al., Bone remodeling around implants with external hexagon and morse-taper connections : a randomized, controlled, split-mouth, clinical trial ». Clinical implant dentistry and related research 19, 2017.

F. Pieri, N. N. Aldini, C. Marchetti, and E. G. Corinaldesi, « Influence of implant-abutment interface design on bone and soft tissue levels around immediately placed and restored single-tooth implants: a randomized controlled clinical trial ». The international journal of oral & maxillofacial implants 26, pp.169-78, 2011.

A. Pozzi, M. Tallarico, and P. K. Moy, « Three-year post-loading results of a randomised, controlled, splitmouth trial comparing implants with different prosthetic interfaces and design in partially posterior edentulous mandibles, European journal of oral implantology, vol.7, issue.1, pp.47-61, 2014.

R. Ranieri, A. Ferreira, E. Souza, J. Arcoverde, F. Dametto et al., The Bacterial Sealing Capacity of Morse Taper Implant???Abutment Systems in Vitro, Journal of Periodontology, vol.86, issue.5, pp.696-702, 2015.
DOI : 10.1902/jop.2015.140623

G. E. Romanos, H. Malmstrom, C. Feng, C. Ercoli, and E. J. Caton, « Immediately loaded platform-switched implants in the anterior mandible with fixed prostheses: a randomized, split-mouth, masked prospective trial ». Clinical implant dentistry and related research 16, pp.884-92, 2014.

J. F. Santiago, V. E. De-souza-batista, F. R. Verri, H. M. Honório, C. C. De-mello et al., Platform-switching implants and bone preservation: a systematic review and meta-analysis, International Journal of Oral and Maxillofacial Surgery, vol.45, issue.3, pp.332-377, 2016.
DOI : 10.1016/j.ijom.2015.11.009

A. Scarano, L. Valbonetti, M. Degidi, R. Pecci, A. Piattelli et al., « Implantabutment contact surfaces and microgap measurements of different implant connections under 3-dimensional x-ray microtomography ». Implant dentistry 25, pp.656-62, 2016.

J. Schrotenboer, Y. Tsao, V. Kinariwala, and H. Wang, Effect of Microthreads and Platform Switching on Crestal Bone Stress Levels: A Finite Element Analysis, Journal of Periodontology, vol.79, issue.11, pp.2166-7210080178, 1902.
DOI : 10.1902/jop.2008.080178

D. Schulze, M. Heiland, H. Thurmann, and E. G. Adam, Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiography, Dentomaxillofacial Radiology, vol.33, issue.2, pp.83-86, 2004.
DOI : 10.1259/dmfr/28403350

F. P. Strietzel, K. Neumann, and E. M. Hertel, « Impact of platform switching on marginal peri-implant bone-level changes. a systematic review and meta-analysis ». Clinical oral implants research 26, 2015.

W. Teixeira, R. F. Ribeiro, S. Sato, and E. V. Pedrazzi, « Microleakage into and from two-stage implants: an in vitro comparative study ». The international journal of oral & maxillofacial implants 26, pp.56-62, 2011.

M. Tesmer, S. Wallet, T. Koutouzis, and E. T. Lundgren, Bacterial Colonization of the Dental Implant Fixture???Abutment Interface: An In Vitro Study, Journal of Periodontology, vol.80, issue.12, pp.12-1991, 1902.
DOI : 10.1902/jop.2009.090178

D. Tripodi, G. Vantaggiato, A. Scarano, V. Perrotti, A. Piattelli et al., An In Vitro Investigation Concerning the Bacterial Leakage at Implants With Internal Hexagon and Morse Taper Implant-Abutment Connections, Implant Dentistry, vol.21, issue.4, pp.335-374, 2012.
DOI : 10.1097/ID.0b013e31825cd472

Y. Wang, J. Y. Kan, K. Rungcharassaeng, P. Roe, and J. L. Lozada, Marginal bone response of implants with platform switching and non-platform switching abutments in posterior healed sites: a 1-year prospective study, Clinical Oral Implants Research, vol.23, issue.2, pp.220-247, 2015.
DOI : 10.1902/jop.2010.100491

D. Weng, M. J. Nagata, A. F. Bosco, and L. G. De-melo, « Influence of microgap location and configuration on radiographic bone loss around submerged implants: an experimental study in dogs ». The international journal of oral & maxillofacial implants 26, pp.941-987, 2011.

?. Implant, In Fixed prosthodontics: principles and clinics, 441? 75, 2011.

Y. Yamanishi, S. Yamaguchi, S. Imazato, T. Nakano, and E. H. Yatani, Effects of the Implant Design on Peri-Implant Bone Stress and Abutment Micromovement: Three-Dimensional Finite Element Analysis of Original Computer-Aided Design Models, Journal of Periodontology, vol.85, issue.9, pp.333-338, 2014.
DOI : 10.1902/jop.2014.140107

Y. Yamanishi, S. Yamaguchi, S. Imazato, T. Nakano, and E. H. Yatani, Influences of implant neck design and implant???abutment joint type on peri-implant bone stress and abutment micromovement: Three-dimensional finite element analysis, Dental Materials, vol.28, issue.11, 2012.
DOI : 10.1016/j.dental.2012.07.160

G. A. Zarb, T. Et, and . Albrektsson, « Consensus report: towards optimized treatment outcomes for dental implants ». The journal of prosthetic dentistry 80, p.641, 1998.

H. Zipprich, P. Weigl, B. Lange, and H. Lauer, « Erfassung, ursachen und folgen von mikrobewegungen am implantat-abutment-interface, pp.31-46, 2007.