Étude NpUBD : détection des nodules pulmonaires, comparaison d’une acquisition scanner ultra-basse dose (à une irradiation proche de la radiographie thoracique face et profil) versus basse dose

Abstract : Introduction: Lung cancer screening using computed tomography (CT) is currently being discussed but repeated radiation exposure is a real concern. The aim of npUBD (NCT03305978), a prospective monocentric study, is to show that an ultra-low dose (UBD) CT using recently introduced iterative reconstruction (ASIR-V) is as efficient as a reference low-dose (BD) CT for the detection of ≥4mm uncalcified pulmonary nodules. Methods and analysis: For each patient included in the study (150 planned), a UBD CT is performed in addition to the reference BD CT. This additional UBD CT is reconstructed with 50 and 100% ASIR-V (UBD50; UBD100). The 3 anonymized series are read independently by 2 pairs of radiologists. The detection sensitivity of ≥4mm uncalcified pulmonary nodules with UBD CT versus BD CT is the main judgement criterion. Secondary objectives include concordance of nodules, emphysema and coronary calcifications. Interim results: Among the first 50 patients, 10 were secondarily excluded for the following reasons: ≥6 nodules in at least one lung (n=9) and BMI>35 (n=1). 55 nodules were identified in 26 patients on the reference BD. Mean effective dose is 1.3mSv for UBD and 0.1mSv for BD. The UBD versus BD detection rate is 72.7% (UBD50) and 76.4% (UBD100) (p>0.05), ranging respectively from 50 and 58.3% for ground glass nodules to 78.9 and 81.6% for solid nodules. Conclusion: The radiation dose delivered by UBD is <10% to that of BD CT. The intermediate results show a lower detection rate of ≥4mm pulmonary nodules than expected but need to be confirmed by the final analysis.
Document type :
Master Thesis
Complete list of metadatas

Cited literature [45 references]  Display  Hide  Download

https://dumas.ccsd.cnrs.fr/dumas-02421778
Contributor : Jean-Hugues Morneau <>
Submitted on : Friday, December 20, 2019 - 4:31:10 PM
Last modification on : Wednesday, July 15, 2020 - 8:58:04 AM
Long-term archiving on: : Saturday, March 21, 2020 - 7:40:54 PM

File

2018GREA5127_ludwig_marie(1)(D...
Files produced by the author(s)

Identifiers

  • HAL Id : dumas-02421778, version 1

Citation

Marie Ludwig. Étude NpUBD : détection des nodules pulmonaires, comparaison d’une acquisition scanner ultra-basse dose (à une irradiation proche de la radiographie thoracique face et profil) versus basse dose. Médecine humaine et pathologie. 2018. ⟨dumas-02421778⟩

Share

Metrics

Record views

61

Files downloads

373